INF-TN1FSH-E
- 137 -
7.15.2. Received Signal (optional function)
Click “RECEIVED SIGNAL”, and the following screen appears.
Fig. 28 <Received signal screen>
Select either Line 1 or Line 2 first. Then, select one from forward direction received wave, reverse direction received
wave, forward direction filter, reverse direction filter and correlation waveform. Depending on measurement method
(method 1, method 2 and method 3), items which can be selected vary as shown below. Trigger level is also displayed.
Left-click the mouse while pressing the shift key to specify the screen range, and the selected range is magnified.
Press the R key to return to original status.
•
Method 1: One from forward direction, reverse direction and correlation waveform can be selected.
•
Method 2: One from forward direction, reverse direction, forward direction filter and reverse direction filter can be
selected.
•
Method 3: One from forward direction, reverse direction, forward direction filter and reverse direction filter can be
selected.
[Start].......................... Starts reading in idicated cycle.
[Stop] .......................... Stops reading
[Save As CSV]............ Saves the measurement result in a file in CSV format. Click the button, and you are
prompted to enter the name of a file to which the data is to be saved. Specify the
destination to save and enter the file name, and a CSV file is created.
Signal
waveform
Trigger level