APPENDIX C - ADDITIONAL INFORMATION
ST100 Series Flow Meter
80
Fluid Components International LLC
– Get from Device (button)
– Send to Device (button)
■ SD Card Log Files (frame)
– Show List of Log Files (button)
– List of Log Files (Log File Name, Size) (list box)
– Upload Selected Log File(s) (button)
▬ Totalizer
■ Totalizer (frame)
– Totalizer enabled/disabled (check box)
– Show/Hide Totalizer Value (check box)
– Reset Totalizer to Zero (button)
■ Get from Device (button)
■ Send to Device (button)
▬ Pressure Offset
■ Pressure (frame)
– Zero (button)
– Offset (text box)
– Apply Offset (button)
■ Get from Device (button)
● a
DvanceD
s
etuP
▬ User Parameters
■ Customer Min/Max (frame)
– Cust. Min/Max Flow (text box, customer units)
– Cust. Min/Max Temperature (text box, customer units)
– Cust. Min/Max Pressure (text box, customer units)
■ K Factor (frame)
– K Factor 1 (text box)
– K Factor 2 (text box)
– K Factor 3 (text box)
– K Factor 4 (text box)
■ Miscellaneous (frame)
– Density (text box)
– Flow Damping (text box)
■ Get from Device (button)
■ Send to Device (button)
▬ Ethernet
■ Ethernet Settings (frame)
– Unit IP Address
– Gateway Address
– Subnet Mask
■ Get from Device (button)
■ Send to Device (button)
▬ Date and Time
■ Date and Time (frame)
– Date (calendar date picker)
– Time (spinner)
■ Get from Device (button)
■ Send to Device (button)
▬ Download Calibration
■ Get Calibration File (frame)
– File name path (text box & “Browse” button)
■ Select Group For Download (frame)
– Group (drop-down list)
■ Select FE For Download (frame)
– FE (drop-down list)
■ Send to Device (button)
● c
onfiguration
▬ Output
■ Analog Output Board. (4-20mA, Freq., Pulse &
HART) (radio button)
– Analog Output Selection (frame)
○ 4-20mA #1: (drop-down list)
◊ 4mA @ Units ≤ (text box)
◊ 20mA @ Units ≥ (text box)
○ 4-20mA #2: (drop-down list)
◊ 4mA @ Units ≤ (text box)
◊ 20mA @ Units ≥ (text box)
○ 4-20mA #3: (drop-down list)
◊ 4mA @ Units ≤ (text box)
◊ 20mA @ Units ≥ (text box)
○ Frequency (drop-down list)
◊ Range: (drop-down list)
○ Pulse: (drop-down list)
◊ X (multiplier): (drop-down list)
■ Digital Output Board (Modbus, Foundation Fieldbus
& Profibus) (radio button)
– Digital Output Selection (frame)
○ Digital Bus (drop-down list)
■ Get from Device (button)
■ Send to Device (button)
▬ 4-20mA User
■ 4-20mA #1
– Manual mA Output (text box)
– Click to Output Manual (button)
– NAMUR Enabled (check box)
○ Set NAMUR @ 3.6 mA (button)
○ Set NAMUR @ 21.0 mA (button)
○ NAMUR mA (text box)
○ NAMUR counts (text box)
○ Click to Test NAMUR (button)
■ 4-20mA #2
– Manual mA Output (text box)
■ 4-20mA #3
– Manual mA Output (text box)
– Click to Output Manual (button)
■ Get from Device (button)
Содержание ST100 series
Страница 12: ...GENERAL ST100 Series Flow Meter 6 Fluid Components International LLC Intentionally Left Blank ...
Страница 38: ...OPERATION ST100 Series Flow Meter 32 Fluid Components International LLC Intentionally Left Blank ...
Страница 40: ...MAINTENANCE ST100 Series Flow Meter 34 Fluid Components International LLC Intentionally Left Blank ...
Страница 54: ...TROUBLESHOOTING ST100 Series Flow Meter 48 Fluid Components International LLC Intentionally Left Blank ...
Страница 80: ...APPENDIX C ADDITIONAL INFORMATION ST100 Series Flow Meter 74 Fluid Components International LLC ...
Страница 81: ...ST100 Series Flow Meter APPENDIX C ADDITIONAL INFORMATION Fluid Components International LLC 75 ...
Страница 82: ...APPENDIX C ADDITIONAL INFORMATION ST100 Series Flow Meter 76 Fluid Components International LLC ...
Страница 92: ...APPENDIX D GLOSSARY ST100 Series Flow Meter 86 Fluid Components International LLC Intentionally Left Blank ...
Страница 94: ...APPENDIX E APPROVALS ST100 Series Flow Meter 88 Fluid Components International LLC Intentionally Left Blank ...