ST100 Series Flow Meter
OPERATION
Fluid Components International LLC
25
Upload Selected Log File(s) to a PC Using a USB Cable and the ST100 Configuration Application
It is possible to upload selected log file(s) to a PC using a USB cable and the ST100 configuration software application without removing the
memory card from the ST100 electronics.
Start the ST100 configuration application. Click
USB Connect
on the home screen. Select the
Basic Setup
branch from the menu tree on the
window's left side. Select the
SD Card Logging
tab. In the
SD Card Log Files
frame click
Show List of Log Files
. Select the desired file(s)
from the list displayed. Click
Upload Selected Log File(s)
. A file dialog pops up showing the host computer file locations (like Windows
Explorer). Select the desired location to store the file and click
OK
. The file is then copied to the specified host computer location.
Internal Delta-R Resistor Check
The Internal Delta-R Resistor Check (IDR) is a routine designed to assess the ST100 internal normalization. The normalization process fine tunes the
instrument’s ability to accurately measure resistance. Proper normalization also allows FCI electronics to be interchangeable for replacements, spares
or repaired boards. If the unit’s normalization shifts, the accuracy of the meter may be compromised.
By passing the same sensor excitation current used to power the RTDs across three high precision IDR resistors (60
Ω
, 100
Ω
and 150
Ω
) trendng
patterns can be established. Periodically run the IDR check to verify proper operation of the ST100 electronics package. Use the IDR check as a
troubleshooting tool to isolate a fault between the sensor and the electronics.
Running the Internal Delta-R Resistor Check
There are two ways to run the Internal Delta-R Resistor Check.
Using the HMI:
Hold the “Hot Key” (top sensor) for three seconds. Select “Diagnostics.” Select “Self Test.” Select “FE 1 IDR” (or FE 2 IDR if present) and
enter the User Level Password (E#C). See Appendix C, page 78 for the IDR display sequence.
The IDR routine runs and the resulting values are shown on the HMI. These values are not saved and must be recorded by hand if required.
When a scheduled Internal Delta-R Check is running the HMI shows the Fault icon (exclamation point inside a triangle) displayed above the
flow rate. If the IDR check is triggered via the HMI, the message
FE 1 IDR Test in Progress
is shown. Data from an HMI-initiated IDR check is not
saved. IDR data can only be saved to the microSD card via the PC configuration application's
Scheduled Tests
tab (Diagnostics).
Using the ST100 Configuration Software Application:
Click
USB Connect
on the home screen. Select the
Diagnostics
branch from the menu tree on the window's left side. Select the
Scheduled
Tests
tab. Select the “FE #” desired from the drop-down list.
Select desired
Mode
via the drop-down list. The check can be run on a Day of Month (1-28), Every Nth Day (1-255), Day of Week (0=Sun),
Every Day. Use the
Day, #days, DOW
spinner control to define the Mode selection above. Use the
Time
spinner control to enter the desired
time of the scheduled check. Alternatively, click
Run Check Now
to run the IDR check on demand.
After clicking
Run Check Now
a dialog box displays the expected and the measured resistance values. These instant checks are not logged
to the FRAM and not displayed under the
Test Logs
tab as the Scheduled Tests files. Furthermore, they cannot be added to the SD card logs.
Internal Delta R Scheduled Tests Setup
Содержание ST100 series
Страница 12: ...GENERAL ST100 Series Flow Meter 6 Fluid Components International LLC Intentionally Left Blank ...
Страница 38: ...OPERATION ST100 Series Flow Meter 32 Fluid Components International LLC Intentionally Left Blank ...
Страница 40: ...MAINTENANCE ST100 Series Flow Meter 34 Fluid Components International LLC Intentionally Left Blank ...
Страница 54: ...TROUBLESHOOTING ST100 Series Flow Meter 48 Fluid Components International LLC Intentionally Left Blank ...
Страница 80: ...APPENDIX C ADDITIONAL INFORMATION ST100 Series Flow Meter 74 Fluid Components International LLC ...
Страница 81: ...ST100 Series Flow Meter APPENDIX C ADDITIONAL INFORMATION Fluid Components International LLC 75 ...
Страница 82: ...APPENDIX C ADDITIONAL INFORMATION ST100 Series Flow Meter 76 Fluid Components International LLC ...
Страница 92: ...APPENDIX D GLOSSARY ST100 Series Flow Meter 86 Fluid Components International LLC Intentionally Left Blank ...
Страница 94: ...APPENDIX E APPROVALS ST100 Series Flow Meter 88 Fluid Components International LLC Intentionally Left Blank ...