Soap Dispensing
Range Adjustments
No adjustments are required for most settings.
Factory default range is set at 12 cm.
The factory
setting should be satisfactory for most
installations.
To adjust the dispensing range:
1. Using a flat head screw driver remove the
screw and lower the front box cover.
2. Using a phillips screw driver remove the
two phillips screw & the washers that are
securing the soap cartridge. Ensure the
both the rubber sopa & battery caps are
tightly secured onto the soap cartridge.
3. Turn the cartridge upside down.
4. With a small flat screw driver turn the
potentiometer (small brass dial) clockwise
to increase sensing range &
counterclockwise to reduce range.