FBII XL-2T Скачать руководство пользователя страница 9

- 9 -

Account #

                                                

Telephone #                                                 

Turning The System On

IS THE SYSTEM READY?

You can turn the burglar portion of your security system ON and OFF. Before

you can turn the system ON, it must be “ready.” If you have a protected door

open, or someone is moving in view of a motion detector, the system will not

display “

READY

.”

The system is ready if the READY light is ON or if the display shows:

SYSTEM READY

WHEN SYSTEM IS NOT READY

If the system is 

not

 ready to be armed, the READY light will be

 OFF

 and the

zone lights will show which zone or zones are not ready. The following

conditions will be indicated by the zone lights or described on the display:

Fast Blink

 ...................................Alarm

Slow Blink/Low Intensity

  .........Bypass

Slow Pulse

 ..................................Trouble

Solid ON

  .....................................Not Ready

Example:

 If the 

READY 

light is 

not

 lit and the

 Zone 1

 light 

is solid ON

, an

alarm sensor on Zone 1 is faulted. This might mean that a door is open or

someone is walking in view of a motion sensor. Check all sensors on Zone 1 and

resolve the problem. When all sensors are restored, the READY light will come

ON and the zone light will go out.  In this example, the display shows:

SYSTEM NOT READY

Determine which zone or zones are not ready, resolve the problem, and turn the

system ON normally. If the problem cannot be resolved, you may 

bypass

 the

zone that is not ready. Bypassing should only be done if the problem on the zone

cannot be resolved, OR if you intentionally wish to leave the zone OFF.
For example, you would leave the zone OFF if you plan to keep the window open

for ventilation. 

Zones

 

that are bypassed are not protected when the

system is ON. 

See 

Bypass

 on the following page for a description of the

procedure.

and

NOT RDY

ZONE 1

FRONT DOOR

Содержание XL-2T

Страница 1: ...X XL L 2 2T T Security System User Guide N9819V3 2 00 FIRE BURGLARY INSTRUMENTS INC...

Страница 2: ...F 12 USER CODES 13 MISCELLANEOUS COMMANDS 14 TESTING THE SYSTEM 16 NATIONAL FIRE PROTECTION ASSOCIATION RECOMMENDATIONS ON SMOKE DETECTORS 17 EMERGENCY EVACUATION 18 GLOSSARY 20 FEDERAL COMMUNICATIONS...

Страница 3: ...your 4 digit user code 3 The system ON ARM light will go out TO TURN SYSTEM ON AND STAY INSIDE 1 Check to make sure the system is ready Green READY light is lit 2 Press STAY 3 Enter your user code The...

Страница 4: ...4 The ON OFF ARM light the INSTANT light and the STAY light will all be on TO RESET SMOKE DETECTOR 1 Enter your 4 digit user code READY light is not available on all keypads...

Страница 5: ...your security system Your Security Company representative will suggest the model most appropriate for your premises and your needs The XL 2T is listed by Underwriters Laboratories for Household Fire a...

Страница 6: ...same for all designated Entry Exit doors SEND HELP ALERT All keypads are equipped with emergency pair keys In order to activate the alert both keys must be pressed at the same time The type of keypad...

Страница 7: ...7 Buttons on XL 4600SM keypad only...

Страница 8: ...___________ If user 13 is not assigned to door strike then any user can activate the door strike 14 Only Turns System ON Yes If No __________________ 15 Ambush Duress Code Yes If No __________________...

Страница 9: ...he READY light is not lit and the Zone 1 light is solid ON an alarm sensor on Zone 1 is faulted This might mean that a door is open or someone is walking in view of a motion sensor Check all sensors o...

Страница 10: ...ser code When the system has been turned on successfully the ON OFF ARM light and the STAY light will be lit or the LCD will display ON STAY REMEMBER You must turn the system OFF if you want to open t...

Страница 11: ...unbypass procedure or when you turn the system OFF Bypassing can only be done while the system is turned OFF Press the BYPASS button Then enter your user code and the zone number 1 7 to be bypassed a...

Страница 12: ...rms occurred when the system was ON or if a trouble condition exists the zone LED s will indicate it as follows Fast Blink Alarm Slow Blink Low Intensity Bypass Slow Pulse Trouble Solid ON Not Ready o...

Страница 13: ...emergency Ambush or Duress signal You may also have chosen to reserve one user code that is only allowed to turn the system ON This code will NOT be able to turn the system OFF TO DELETE A USER CODE...

Страница 14: ...ing your system OFF always requires a valid user code Press 1 QUICK FORCED ON If programmed by your installer Quick Forced ON allows you to turn the burglar portion of your alarm system ON to the AWAY...

Страница 15: ...t Example 7AM 07 3PM 15 Set minutes the same way 5min 05 25min 25 The readout keypad will prompt you for the required entries DOOR STRIKE Door strikes are used in access control applications To activa...

Страница 16: ...th In order to test your backup standby battery the following procedure should be followed 1 Unplug the transformer from the AC outlet by removing the restraining screw that secures the transformer to...

Страница 17: ...ion of fire detection equipment in all rooms and areas of the household as follows A smoke detector installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on ea...

Страница 18: ...and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room 4 Assure that all bedroom doors...

Страница 19: ...19...

Страница 20: ...ring center contacted by your security system over the telephone and or other communication channels when alarms are activated if your system is programmed to communicate alarms off site The Central S...

Страница 21: ...ration that allow you to protect part of your premises while you remain inside Fire sensors and other emergency and environmental features are always active and ready they are not affected in any way...

Страница 22: ...tions For an example see DURESS SYSTEM Your security system is composed of three main parts 1 the control panel which functions as the system brain and the link to the monitoring agency Central Statio...

Страница 23: ...cator Plug the control communicator into a different outlet so that it and the receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio televis...

Страница 24: ...o the system It must be returned to the factory or an authorized service agency for all repairs This control unit was manufactured under rigid quality standards and complies with all UL requirements f...

Страница 25: ...of the reasons smoke detectors used in conjunction with the System may not work are as follows Smoke detectors may not sense fires that start where smoke cannot reach the detectors such as in chimney...

Страница 26: ...stem can reduce their detection ability Passive Infrared Detectors sense changes in temperature however as the ambient temperature of the protected area approaches the temperature range of 90 degrees...

Страница 27: ...if the system responds to the emergency as intended occupants may have insufficient time to protect themselves from the emergency situation In the case of a monitored alarm system authorities may not...

Страница 28: ...NAL PURCHASE ANY ACTION FOR BREACH OF ANY WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY MUST BE BROUGHT WITHIN 60 MONTHS FROM DATE OF ORIGINAL PURCHASE IN NO CASE SHALL...

Страница 29: ...Y CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT WHILE SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty gives you specific legal rights and you may also have other rights which v...

Страница 30: ...N9819V3 N9819V3 2 00 FIRE BURGLARY INSTRUMENTS INC Subsidiary of PITTWAY CORPORATION 149 Eileen Way Syosset New York 11791...

Отзывы: