7.2
MACHINE ACCESS (SEE FIGURE 7.2)
A. Machine Operator Display
Mode Display
Description
Preset Value
1. VERSION
Shows current version of the software installed.
2. TIME
Used to set the time of day. The machine uses a
24 hour format (military time) clock. The clock has a
battery backup which maintains correct time even if
not plugged into electrical power.
3. DATE
Used to set the date and day of the week.
mmm-dd dow
4. DAYLIGHT
Sets Daylight Savings Time (DST) option. ON for
SAVINGS
use of DST; OFF for use of Standard time.
5. DEFROST TIMES
Each side can defrost itself up to 12 times a day.
4 hours
Set the defrost times so the machine does not
defrost during periods of high demand.
Low demand, every 3 hours. High demand, every
4-5 hours. Offset Left Side and Right Side defrost
times by 60 minutes.
6. WAKE/SLEEP TIME Sets the machine wake and sleep times.
00:00
To manually wake-up and operate the unit, press
DEFROST, then RUN.
7. FAULT CODE
This feature stores the last 10 error codes and helps
HISTORY
the service agent to readily diagnose a problem.
The readout is formatted as shown in the two
examples below.
0 : Out of syrup
(first error is an out
of syrup error)
0S:04/03/00 12:31:05
(error started at
12:31 PM on 4/3/00)
0E:04/03/00 13:33:56
(error ended at
1:33 PM on 4/3/00)
1 : Out of CO
2
(second error is an
out of CO
2
error)
1S:04/07/00 15:03:55
(error started at
3:03 PM on 4/7/00)
1E:04/08/00 10:26:01
(error ended at
10:26 AM on 4/8/00)
The same format continues on for errors 2 through 9.
8. SERVICE MENU
Authorized technician access.
N/A
Service Note:
Press “DEF” and then “RUN” on the control panel to start a machine that
has been turned off manually. This allows the machine to automatically
reset the baseline.
11