FAURE-HERMAN
COMPONENT MAINTENANCE MANUAL
744-082 / 744-082-3
28-49-91
PAGE 109
MAR 31/07
(c)
AS332 helicopter
-
Select the AS332 helicopter using the rear RH selector.
-
Close switch I
1
.
-
Close switch I
5
.
-
Set LF generator G1 to a frequency of 87.41 Hz and an amplitude of 100 mV rms.
-
Set resistance boxes BR1 and BR2 to 10 K
.
-
Switch off LF generator G1.
-
Set the "DEBIT-FLOW/T-Q.REST/PRESET" switch to "PRESET".
-
Select 201 on the RH display using the "-/+" switch.
-
Set the "DEBIT-FLOW/T-Q.REST/PRESET" switch to "T-Q.REST".
-
Check that the LH and RH displays read 959 and 201, respectively.
-
Switch on LF generator G1 and start the pulse counter by closing switch I
G
when
200 is reached. Check that the LH display (remaining flight time) reads 205 ± 2 for
the first 30 seconds.
-
Open switch I
G
when 196 is reached.
-
The number of pulses recorded must be 13111 ± 500.
-
Switch off LF generator G1.
-
Open switch I
1
.
(d)
Memorizing the quantity of fuel remaining
-
Close switch I
1
.
-
Set the "DEBIT-FLOW/T-Q.REST/PRESET" switch to "T-Q.REST".
-
Note the quantity of fuel remaining indicated by the RH display.
-
Open switch I
1
.