1
and open switch 1
2
.
-
Set the "DEBIT-FLOW/T-Q.REST/PRESET" switch to "DEBIT-FLOW".
-
Check that LF generator G1 is off.
-
The RH and LH indicators must display 000.
-
Turn the brightness adjustment knob fully clockwise.
-
Check that current consumption does not exceed 320 mA, with 28 V applied.
(3)
Lighting circuit test
-
Check that face panel lighting is correct by closing switches I
3
or I
4
or I
3
and 1
4
.
-
Close switch I
3
and open switch 1
4
.
-
Check that current consumption is 120 mA ± 15 mA, with 28 V applied.
(4)
Dimming function check
-
Close switch I
1
.
-
Check that the brightness of LH and RH displays varies according to the position of the
"TEST - DIM" brightness control knob. Turning the knob clockwise increases the
brightness.
(5)
Test function check
-
Check that LF generator G1 is off.
-
Close switch I
6
(P/N 744-082 only).
-
Close switch I
1
.
-
Depress the brightness control knob (also used as a test button) and check that the LH and
RH displays read "888" and the spare indicator light is on.
-
On flowmeter 744-082 only :
-
Open switch I
6
.
-
Ground connector pin R for the test.
-
Depress the test button (brightness control knob) and check that both displays go out
and the spare indicator light flashes (this corresponds to the internal battery test).