39
25. Trouble-shooting
Trouble-shooting
Error messages are shown with LED 3 blinking. A detailed information on the error type
can be obtained using the TE (Tell Error) command.
There are two types of error code: one for input errors (WH wait high or WL wait low) and
the other for controller errors (DP deviation position or over-heating).
Error code Description
Remarks
01 to 12
Waiting for input (low or high)
- Continues if status has been reached or
restart with HO, SM or PQ, PW.
50
Deviation position too great
- Difference between the internal
calculated position and actual motor
position greater than the number of
increments defined in DP (deviation
position).
60
Power stage over-heating
- > 80
°
C detected by the temperature
sensor.
61
Power supply over voltage
- Power supply voltage or retarding energy
on ballast circuit to high.
62
Ballast circuit active too long
- If the ballast circuit is active for more
than 5 seconds the power stage is
switched off.
26. Operating system error
If the message “user program corrupted” appears on the screen, the operating system
has to be turned off and re-started manually. This is done as follows:
•
set the S1 switch from OFF to ON (the SMD multiswitch is located
be between the battery a the 9 poles D-sub RS232 connector)
•
re-load the xx36_yyy.S19 program
•
turn the S1 switch from ON to OFF position
The system can now be switched on normally.
Specifications subject to change without notice