Subject to change without notification
Subject to change without notification
Type
Value/Effect Command
38
5.3 Factory Configuration
The MCBL will be configured as follows in the as-delivered condition. It can be restored to this
state again with the command
fconfig
. If a different start-up configuration is required, this
must be specifically set up and stored via the command
save
.
1)
The drive is in analog mode when it is delivered, so therefore the direction switch and
Start/Stop button will be recognized. These lines refer to the other modes, in which these
two switches are not normally recognized.
Input source
Drive type
Direction of rotation
Overcurrent limit
Asynchronous signals
Node number
Direction switch in non-analog modes
1)
Start/Stop button in non-analog modes
1)
Voltage compensation
Maximum rotational speed
Step width in stepper motor mode
Multiplication factor in pointer mode
Zero point shift in pointer mode
Analog theshold voltage
Terminal echo
analog input (potentiometer)
Continuous
Right
350 mA
Permitted
0
Ignored
Ignored
590 mV
eff
at 120 000 rpm
120 000 rpm
1
1.00
0
49 mV*V
Signals are not echoed
sor 1
contmod
adr
lpc 350
asyn 1
nodeadr 0
smd 0
sms 0
comp 590
sp 120000
stw 1
ptrfac 100
ptroff 0
mav49
echo 0