Therefore, in stepper-motor mode the acceleration ramp should be set to the lowest possible
value, in order to avoid speed oscillations.
Warning:
If stepper-motor mode is selected and the drive is switched off with
di
, the internal
pulse counter will still continue to run. If it is switched on again with
en
, the drive will im-
mediately activate, and will travel to the position indicated by the pulse count which it had
already registered up to the instant when it was switched. If this is not what is wanted, the
pulse train must be interrupted. Exactly the same result is obtained if the input source is
switched internally with the command
sor
. With
sor 0
or
sor 1
the drive remains stationary,
but the pulses are counted, and after switching with
sor 2
they will be processed.