Cables and Connections
8
Fault Output
The system is outfitted with a fault output
through which system errors are signalled.
Fault Output Characteristics:
■
Switch to ground (open collector)
■
Output Resistance: switched through
(low level): 47 Ohms, open (high level):
10 kOhms
■
In the case of a system error the switch
is open, (the LED is not lit.)
■
Output current maximum 30 mA, voltage
in open condition may not exceed supply
voltage
The fault output is activated as a result of the
following situations:
■
Dynamic current limiting active
■
Low voltage (by voltage under 10 V)
■
Overvoltage protection active
(by supply voltage over 32 V)
■
Overtemperature protection active
The fault output port can also be configured
to perform other functions:
■
Pulse output
■
Digital output
■
Limit switch input
■
Direction of rotation input