Configuring the Velocity Control
16
Setting the Direction of Rotation:
Command Function
Description
Example
ADL *)
Analog Direction Armature rotates left
ADL
Left
with positive voltage at
the analog input
ADR *)
Analog Direction Armature rotates right with
ADR
Right
positive voltage at the
analog input
Command Function
Description
Example
V *)
Select Velocity
Activates velocity control
V2000
Mode
mode and rotates with
the given value
GV
Get Velocity
Calls up the
GV
command velocity
➔
500
Default Setting: ADR ... Right rotation with positive voltage.
b.) Command Velocity with Pulse Width Modulation (PWM)
at the Analog Input
The factory setting are:
■
Pulse Duty Ratio > 50 %
➔
Rotation Right
■
Pulse Duty Ratio = 50 %
➔
Rotation Stop
■
Pulse Duty Ratio < 50 %
➔
Rotation Left
The commands SP, MV, MAV, ADL and ADR can also be used
in this mode.
c.) Command Velocity at the RS-232 Port:
Directly following the SOR0-Command the motor continues
rotating with the current command velocity.
Special Setting: Constant Velocity
SOR0 [enter]
➔
Switches to RS-232 Mode
V500 [enter]
➔
Enter desired velocity
EEPSAV [enter]
➔
Saves setting to EEPROM
Now the motor will always start with the saved velocity.