17
Configuring the Velocity Control
Setting an Acceleration:
Command Function Description
Example
AC *)
Load Command
Loads a new value for
AC100
Acceleration
acceleration Arguement
in Rev/s2
GAC
Get Acceleration Calls up current
GAC
accelaration value
➔
1000
Default Setting: 30000 Rev/s
2
This acceleration value makes soft acceleration and braking
in Velocity Control Mode possible.
Direction of Rotation Input:
The Fault Output can be configured to serve as a direction of
rotation switch.
Command Function Description
Example
DIRIN *)
Direction Input
Sets the fault output to
DIRIN
function as a direction of
rotation input. (also activates the
limit switch function)
Level and Direction:
Low: 0 V to 0,5 V
... Rotation Left
High: 4 V to Supply Voltage
... Rotation Right
The logic level at the direction of rotation input is dominant to
changes made with the ADR and ADL commands.
When the Fault Output is used as a Direction of Rotation Switch,
it functions with all sources after the setup is initially given over
the RS-232 port.
To take the position limits into account
The position limits (LL-command) will become applicable with
the input of the command
APL1
. With the input of the
APL0
command position limits will be ignored.