The system has one ethernet interface. For this interface you can change the network
settings in this menu.
The Default IP Address is
192.168.10.231
with subnet mask
255.255.255.0
(Prefix length
24
).
The internet gateway could be necessary for future functions of the CCS.
If you want to set the internet gateway, it must be in the same subnet than the system. In this
case it should be in range
192.168.10/24
. The internet gateway is the address of the router
which connect the subnet with the internet.
To change the IP Address, Subnet mask or Internet gateway, click on the corresponding blue
box. A dialog will open.
Use the keypad on the right to type in the decimal IPv4 address in four octets separated by a
dot and press Enter
↲
.
You will go back to the last screen.
It is very important to check the values in the blue boxes again after a click on Enter
↲
. If you
enter an invalid IP address, it can happen that the blue boxes are blank, or they show a
wrong value.
The shown addresses will be set when the system reboots.
You can do this
by disconnecting the power supply or by a click on Reboot now.
When you click on Reboot now, a confirm dialog opens: