Device
and operation
CPC307
C P C 3 0 7 U s e r M a n u a l
40
© 2 0 2 2 F a s t w e l v . 0 0 6
9
DD4
10
DD11
31
IRQ
32
IOCS16#
11
DD3
12
DD12
33
A1
34
PDIAG#
13
DD2
14
DD13
35
A0
36
A2
15
DD1
16
DD14
37
CS0#
38
CS1#
17
DD0
18
DD15
39
DASP#
40
GND
19
GND
20
–
41
+5 В
42
+5 В
21
DRQ
22
GND
43
GND
44
–
Figure 4.9 Numbering of the XP13 connector pins
The 2½” HDD connects directly to the XP13 using the ACS00010 cable (FC44). Other types of
HDD (3½” format), as well as CDROMs having a 40-pin connector with 2.54 mm pitch, are
connected to the module through the CDM02 adapter module (FAPI.469535.023). The adapter
plugs directly into a 40-pin HDD or CDROM socket and connects to the XP13 with an ACS00010
(FC44) cable.
Operation modes of external IDE devices are set by configuring appropriate jumper(s) on external
IDE devices.
Table 4.10 shows the recommended configurations for IDE devices.
Table 4.10.Recommended configurations for IDE devices
1
– to identify the onboard NAND-flash drive after power-up you need to RESET the module (SW1
or the corresponding key combination on the keyboard);
2 - The DVD drive must be connected strictly to the far end of the IDE ribbon cable connector.