6-10
Index List
Category
Name
Index No.
DEC (HEX)
Sub
index
No.
Read/
Write
*1
Backup
Format
Length
in
bytes
Default
Setting details
Remarks (Unit)
Detection
Settings
Response time
95 (0x5F)
0
R/W
✓
UINT
1
4
0x00: 8000 µs
0x01: 2000 µs
0x02: 1000 µs
0x03: 500 µs
0x04: 250 µs
0x05: 70 µs
0x06: 16 µs
General
Settings
Emitter setting: Emitter
status
97 (0x61)
1
R/W
UINT
1
0
0x00: Emitter on
0x01: Emitter off
Emitter setting: Emitter
power
2
R/W
✓
UINT
1
0
0x00: Maximum
0x01: Middle
0x02: Minimum
0x0A: Auto
Emitter setting:
Emitter APC
3
R/W
✓
UINT
1
1
0x00: Off
0x01: On
ASC
112 (0x70)
0
R/W
✓
UINT
1
0
0x00: Off
0x01: On - standard
0x02: On - fast
0x03: On - max
IO-Link
Process data select
120 (0x78)
0
R/W
✓
UINT
1
0
0x00: AO = Present receiving light
level live
0x12: AO = Smart Task analog value
Counter
I/O Settings
Pin 2 setting
121 (0x79)
0
R/W
✓
UINT
1
17
D4RF-TD
0x00: Not used
0x01: External input
0x10: Emitter off
0x11: Teach input
0x03: Load preset
D4RF-T, D4RF-TC4
0x00: Not used
0x01: External input
0x10: Emitter off
0x11: Teach input
0x21: Receiving light level alarm
output
0x22: Switching signal QL2
0x23: Detection output Qint. 1
0x24: Detection output Qint. 2
0x27: Switching signal QL1
0x28: Switching signal QL1/
Pin 5 setting
122 (0x7A)
0
R/W
✓
UINT
1
34
0x00: Not used
0x21: Receiving light level alarm
output
0x22: Switching signal QL2
0x23: Detection output Qint. 1
0x24: Detection output Qint. 2
0x27: Switching signal QL1
0x28: Switching signal QL1/
0x02: Acknowledge
Only D4RF-TD
Diagnosis
Temperature: Present
temperature
153 (0x99)
1
R
INT
1
Temperature: Highest
temperature all time
2
R
INT
1
Temperature: Lowest
temperature all time
3
R
INT
1
Temperature: Highest
temperature since last
reset
4
R
INT
1
Temperature: Lowest
temperature since last
reset
5
R
INT
1
Receiving light level
diagnostic
175 (0xAF)
0
R
UINT
1
0 to 254
255 (not available)
Unit: %
Receiving light level
threshold
176 (0xB0)
0
R/W
✓
UINT
1
0 to 90
Alarm limit for
diagnostic parameters:
High temperature
179 (0xB3)
1
R/W
✓
INT
1
−128 to 127
Alarm limit for
diagnostic parameters:
Low temperature
2
R/W
✓
INT
1
−128 to 127
Alarm limit for
diagnostic parameters:
Operating hours
3
R/W
✓
UINT
4
0 to 1000000
Observation
Present receiving light
level (live)
180 (0xB4)
0
R
UINT
2
Upper Threshold
(switch-on) dynamic
181 (0xB5)
0
R
UINT
2
Содержание D4RF Series
Страница 2: ......
Страница 12: ......
Страница 13: ...1 Read This First This section explains the accessories and the names of this product s parts...
Страница 16: ...1 4 Part Names...
Страница 17: ...2 Installation and Connection This section explains how to install and wire this product...
Страница 25: ...3 Basic Usage This section explains the types of display screens and transitions...
Страница 82: ...3 58...
Страница 83: ...4 Settings Menu This section explains how to set the parameters of this product...
Страница 115: ...5 Troubleshooting This section describes error displays and countermeasures for errors that occur during product use...
Страница 122: ...5 8 Errors and Countermeasures...
Страница 123: ...6 Appendix This section contains information such as the specifications IO Link index list and factory default settings...
Страница 137: ......