4-10
[S6] Display
Example) After executing the teach function with the 1-point Zone or 2-point Zone setting
The thresholds for the upper and lower limits are displayed.
90%
110%
100%
Bar graph
Displays the received light amount on a bar graph.
One or more thresholds are also displayed on the bar graph.
SP2
SP1
SP1
Counter
Displays the set count and the present count in Counter mode.
For details on Counter mode, refer to
“4-6-6 [S7] - [D6] Counter” (page 4-19).
10
6
Edge
This is displayed when Threshold mode is set to Edge height.
When the received light amount changes, the amount of change (difference) is displayed.
For details on Edge height, refer to
“3-7-5 [S7] - [D2] Threshold Mode “Edge height”” (page 3-47).
±30
85
Received light amount
Thresholds
Threshold (lower limit)
Teach mode: 1-point Zone and 2-point Zone
Received light amount
Threshold (upper limit)
Received light amount
Threshold
Teach mode: 1 point, 2 points, Auto, and Through
Present count
Set count
Present amount of change (difference) in the received light amount
Threshold
Edge direction (Positive: +, Negative: −, Both: ±)
Содержание D4RF Series
Страница 2: ......
Страница 12: ......
Страница 13: ...1 Read This First This section explains the accessories and the names of this product s parts...
Страница 16: ...1 4 Part Names...
Страница 17: ...2 Installation and Connection This section explains how to install and wire this product...
Страница 25: ...3 Basic Usage This section explains the types of display screens and transitions...
Страница 82: ...3 58...
Страница 83: ...4 Settings Menu This section explains how to set the parameters of this product...
Страница 115: ...5 Troubleshooting This section describes error displays and countermeasures for errors that occur during product use...
Страница 122: ...5 8 Errors and Countermeasures...
Страница 123: ...6 Appendix This section contains information such as the specifications IO Link index list and factory default settings...
Страница 137: ......