5-3
1
2
3
4
5
Troubleshooting
Error Displays
Error display
Cause
Countermeasure
Teach error 4
(Output indicator
blinks in
orange.)
While executing the teach function of the 2-point
Zone the difference between the received light
amount from the first and second teach
functions was too small to set the thresholds.
Increase or decrease the distance to the object
when setting one of the thresholds. (When using
a diffuse reflective fiber unit.)
While executing the teach function with the
1-point Zone teach mode, the set margin was
too small or the received light amount was too
small to set the thresholds.
Increase the received light amount by
decreasing the distance to the object (when
using a diffuse reflective fiber unit).
Alternatively, set the margin to a larger value.
Teach error 5
(Output indicator
blinks in
orange.)
The execution of the teach function via IO-Link
was not carried out in the correct order.
Correct the IO-Link system commands to teach
the first and second points in order.
Содержание D4RF Series
Страница 2: ......
Страница 12: ......
Страница 13: ...1 Read This First This section explains the accessories and the names of this product s parts...
Страница 16: ...1 4 Part Names...
Страница 17: ...2 Installation and Connection This section explains how to install and wire this product...
Страница 25: ...3 Basic Usage This section explains the types of display screens and transitions...
Страница 82: ...3 58...
Страница 83: ...4 Settings Menu This section explains how to set the parameters of this product...
Страница 115: ...5 Troubleshooting This section describes error displays and countermeasures for errors that occur during product use...
Страница 122: ...5 8 Errors and Countermeasures...
Страница 123: ...6 Appendix This section contains information such as the specifications IO Link index list and factory default settings...
Страница 137: ......