Original notice – User’s manual
26
WARNING
Disposing of condensates in nature is punishable by law.
Have condensate treated by a specialized company.
Adjustments
Adjustment of the operating pressure
for “HGV” reel
1. Pull regulator
A
upwards.
2. Adjust the desired pressure by turning
the knob. Pressure is indicated by
pressure gauge
B
.
3. Press the regulator to lock.
Adjustment of lubricant flow for “HGV”
reel
Adjust the desired flow rate by turning the dial
C
.
For a standard use, it is advisable to see a drop of lubricant per minute in the
control
D
.
Long inactivity
After a long period of inactivity, it is possible that the solenoid valves remain
blocked.
If this is the case, disconnect the device and, with a screwdriver, press the pivot
located at the center of all the solenoid valves of the oil-hydraulic unit to perform
a manual release and then reconnect the device.
A
B
C
D