Installation
Installation instructions Sauna control Series FCU2x00/FCU3x00/FCU4x00 / Version V 2.18
21
Installation and
electrical
connection
1.
Lead the heat resistant signal cable for the sensor through the cable aperture
provided and through the bore of the securing plate.
2.
Place the cable clip as cord grip.
3.
Screw the securing plate with the screws provided. It is important to ensure that the
marking, on the back side, is aligned to the top. When the mounting plate is fixed
wrongly, pent-up water can not drain.
4.
Depending on the sensor used, connect the signal cable to the board as per the
circuit diagram as given in figure 7 or figure 8.
5.
Insert the board in one half of the casing. Pay attention to the indentation in the
sensor plate.
6.
Push the casing half with the board sideways on the securing plate. Pay attention
to the indentation in the securing plate.
7.
Push the other casing half sideways on the securing plate.
8.
Screw on the casing halves with the screws provided.