Installation
20
Installation instructions Sauna control Series FCU2x00/FCU3x00/FCU4x00 / Version V 2.18
5.6.2
Humidity sensor
Following variants of the humidity sensor are available:
Bench sensor for humidity (FCU-SENSOR-HUMIDITY-A)
Combined bench sensor for temperature and humidity
(FCU-SENSOR-HUMIDITY-BENCH-A)
Installation
location
Figure 7: Installation location for humidity sensor/combined bench sensor
Humidity sensor
Install the humidity sensor on the wall on the opposite side of the evaporator at
approximately 1,35 …1,60 m height; this position of the sensor is only a
recommendation for standard cabins.
Attention
: The system installer has to consider cabin-specific conditions, such as
the position of the steam outlet, the supply and outlet air, the door (s), the shape of
the ceiling, etc., and mount the sensor at the appropriate place for this cabin!.
Combined bench sensor for temperature and humidity
Install the combined sensor for temperature and humidity like the bench sensor.