![Fasel Elektronik FCU2000-IR series Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/fasel-elektronik/fcu2000-ir-series/fcu2000-ir-series_operating-manual_3531808036.webp)
Malfunctions
36
Series FCU2000/3000/4000-IR
B_FCUxxxx-IR / Version V 1.07
10.2 Malfunction messages
Possible malfunctions and troubleshooting measures are described in this chapter.
Contact the installer or the dealer of your sauna systems for malfunctions that are not
described below. See the invoice, delivery note or the reverse of this manual for the
address.
If an error occurs during operation, the display shows the error number.
If the error cannot be rectified by the end user, please note down the displayed error
number and contact your service technician.
No.
Malfunction
Possible causes
Troubleshooting
To be carried
out by
000
Internal time error
Internal time error
Service engi-
neer
100
STB circuit open,
STB
The connection to the safety
temperature limiter (STB) is
broken or the thermal fuse
was destroyed by very high
temperature.
Check STB.
Check cable.
Check terminals 29 and 30.
Electrician /
service engi-
neer
200
IR Heater sensor
short circuit
Short circuit IR heater sen-
sor
Check cable.
Check terminals 31 and 32.
Electrician /
service engi-
neer
201
IR Heater sensor
interruption
Cable break IR heater sen-
sor
Contact terminals
Check cable.
Check terminals 31 and 32.
Electrician /
service engi-
neer
210
Bench sensor
short circuit
Short circuit bench sensor
Check cable.
Check terminals 27 and 28.
Electrician/
Service engi-
neer
211
Bench sensor in-
terruption
Cable break bench sensor
Contact terminals
Check cable.
Check terminals 27 and 28.
Electrician /
service engi-
neer
400
External malfunc-
tion message
Optional input for malfuncti-
on of external control unit.
Acknowledge error.
Rectify malfunction in external
device.
User /
Service engi-
neer
11C
I²C error
Error on I²C bus
Disconnect mains, wait for
some time and turn on again. If
error occurs again then contact
the service technician.
Service engi-
neer
485
RS485 error
Error on RS485 bus
Disconnect mains, wait for
some time and turn on again. If
error occurs again then contact
the service technician.
Service engi-
neer
999
Internal time error
Internal time error
Service engi-
neer
Table 10: Malfunction messages