FASANO TOOLS FG 98/DG Скачать руководство пользователя страница 24

H.

 

FREQUENCY 

RANGE

 

RESOLUTION

 

ACCURACY

 

10Hz 

0.001Hz 

 
 

± (0.1%+3) 
 

 

100Hz 

0.01Hz 

1000Hz 

0.01Hz 

10KHz 

0.001KHz 

100KHz 

0.01KHz 

1MHz/20MHz 

0.001MHz 

Overload protection

: 250V 

Input sensitivity: 1V RMS 
 

I.

 

DIODE POWER-ON TEST 

 

DISPLAY VALUE 

TEST CONDITIONS 

 

 

 

 
 
 

 
Diode forward voltage drop 

Forward  DC  current  about  1mA 
Open circuit voltage about 3V 

The buzzer long sounds  
Test the resistance of two points less 
than 50

 

 
Open circuit voltage about 3V 
 

Overload protection:

 250V 

 
 
 
 

DC VOLTAGE MEASUREMENT 

 

Insert the black lead of the measurement probe into the COM port of the multimeter. 

 

Insert  the  red  lead  of  the  measurement  probe  into  the  red  V/

Ω

/Hz  port  of  the 

multimeter. 

 

Rotate the selector to the DC voltage measurement function. 

 

When the probe tips come into contact with the point to be measured (the red tip 
must be put in contact with the positive of the point to be measured) on the display, 
the measured DC voltage value is displayed. 

 
 

7. 

USE 

 

 

 

 

 

Содержание FG 98/DG

Страница 1: ...METRO DIGITALE FG 98 DG Manuale di istruzioni d uso avvertenze e manutenzione NE E vietata la riproduzione anche in forma parziale del presente documento senza l autorizzazione scritta della FASANGAS...

Страница 2: ...3 DESCRIZIONE DELLE PARTI DEL MULTIMETRO 4 SIMBOLI 5 SPECIFICHE TECNICHE 6 DESCRIZIONI DELLE CARATTERISTICHE 7 UTILIZZO 8 INFORMAZIONI PER LO SMALTIMENTO 9 DICHIARAZIONE DI CONFORMITA UE 10 GARANZIA...

Страница 3: ...portata massima come indicato sullo strumento non posizionare il multimetro tra due apparecchiature o tra apparecchiatura e messa a terra Prima dell uso verificare il voltaggio dello strumento da tes...

Страница 4: ...batterie del dispositivo Non utilizzare il multimetro con il coperchio del vano batterie o parti di esso rimosse o danneggiate Al fine di evitare letture errate scosse elettriche o lesioni personali...

Страница 5: ...l dispositivo indica che esso protetto da un doppio isolamento Questo simbolo riportato sulla parte frontale del dispositivo indica che l operatore deve fare riferimento a quanto riportato nel present...

Страница 6: ...ilohm M megaohm 1M 103 k 106 F nF F Unit di misura della capacit elettrica nF nanofarad F microfarad F farad 1F 106 F 109 nF 1012 pF AC Corrente Alternata DC Corrente Continua DC e AC Corrente Continu...

Страница 7: ...ENTO sul display si visualizza il simbolo SOVRACARICO sul display si visualizza il simbolo OL DIMENSIONI 184X90X46 mm PESO circa 320g batteria inclusa ACCESSORI IN DOTAZIONE sonda di misurazione termo...

Страница 8: ...frequenza 40Hz 1000Hz C CORRENTE DC PORTATA RISOLUZIONE ACCURATEZZA 600 A 0 1 A 0 8 10 6000 A 1 A 60mA 0 01mA 600mA 0 1mA 10A 0 01A 2 0 30 Protezione sovraccarico 600mA 600mA 250V D CORRENTE AC PORTAT...

Страница 9: ...to aperto inferiore a 3V Protezione sovraccarico 250V F CAPACITANZA PORTATA RISOLUZIONE ACCURATEZZA 60nF 0 01nF 3 5 20 600nF 0 1nF 6 F 0 001 F 60 F 0 01 F 5 0 10 600 F 0 1 F 6000 F 1 F 60nF 0 01nF Pro...

Страница 10: ...a elettrica tra i due punti inferiore a 50 La tensione del circuito aperto circa 3V Protezione sovraccarico 250V MISURAZIONI DI TENSIONE DC Inserire il puntale nero della sonda di misurazione nella po...

Страница 11: ...periore a 750V rms altrimenti verr danneggiato il circuito elettrico dello strumento Quando si effettuano misure di tensione elevate prestare molta attenzione per evitare scosse elettriche Non appena...

Страница 12: ...tare il selettore sulla funzione selezionare la funzione diodo premendo il pulsante SELECT e mettere in contatto i puntali della sonda di misurazione con il diodo Il valore letto sul display un appros...

Страница 13: ...i spegnimento automatico premere il pulsante SELECT e ruotare contemporaneamente il selettore sul display non verr pi visualizzato il simbolo APO 8 INFORMAZIONI PER LO SMALTIMENTO Questa apparecchiatu...

Страница 14: ...uendolo con altro di pari valore e caratteristiche senza alcuna spesa per l acquirente La garanzia non copre batterie fusibili e guasti causati da un uso inappropriato o errato dell apparecchio o comu...

Страница 15: ...IGITAL MULTIMETER FG 98 DG Instruction manual for use warnings and maintenance NE The reproduction even in partial form of this document is prohibited without the written authorization of FASANGAS S r...

Страница 16: ...CTIONS AND PRECAUTIONS 3 MULTIMETER PART DESCRIPTION 4 SYMBOLS 5 TECHNICAL FEATURES 6 FUNCTION DESCRIPTION 7 USE 8 DISPOSAL INFORMATIONS 9 EU DECLARATION OF CONFORMITY 10 WARRANTY Index Documentation...

Страница 17: ...n the maximum capacity as indicated on the instrument Do not place the multimeter between two pieces of equipment or between the equipment and ground Before use check the voltage of the instrument to...

Страница 18: ...s battery compartment Do not use the multimeter with the battery compartment cover or parts of it removed or damaged To avoid erroneous readings electric shock or personal injury replace the batterie...

Страница 19: ...e indicates that it is protected by double insulation This symbol on the front of the device indicates that the operator must refer to what is reported in this manual to avoid damage to himself or dam...

Страница 20: ...lohm M megaohm 1M 103 k 106 F nF F Unit of measurement of electrical capacity nF nanofarad F microfarad F farad 1F 106 F 109 nF 1012 pF AC Alternating Current DC Direct Current DC e AC both Direct Cur...

Страница 21: ...y LOW BATTERY INDICATION the symbol appears on the display OVERLOAD the symbol appears on the display OL SIZE 184X90X46 mm WEIGHT about 320g battery included ACCESSORIES SUPPLIED measuring probe K typ...

Страница 22: ...equency 40Hz 200Hz C DC current RANGE RESOLUTION ACCURACY 600 A 0 01 A 0 8 10 6000 A 1 A 60mA 0 01mA 600mA 0 1mA 10A 0 01A 2 0 30 Overload protection 600mA 600mA 250V D AC current RANGE RESOLUTION ACC...

Страница 23: ...circuit voltage less than 3V Overload protection 250V F CAPACITANCE RANGE RESOLUTION ACCURACY 60nF 0 01nF 3 5 20 600nF 0 1nF 6 F 0 001 F 60 F 0 01 F 5 0 10 600 F 0 1 F 6000 F 1 F 60nF 0 01nF Overload...

Страница 24: ...esistance of two points less than 50 Open circuit voltage about 3V Overload protection 250V DC VOLTAGE MEASUREMENT Insert the black lead of the measurement probe into the COM port of the multimeter In...

Страница 25: ...ical circuit of the instrument will be damaged When making high voltage measurements be very careful to avoid electric shock As soon as the measurement is finished disconnect the measurement probe tip...

Страница 26: ...UENCY MEASUREMENT Insert the black lead of the measurement probe into the COM port of the multimeter Insert the red lead of the measurement probe into the V Hz port of the multimeter the red lead corr...

Страница 27: ...aging means that at the end of its life the product must be treated separately from household waste and therefore must be sent to the appropriate disposal and recycling centers This operation is the r...

Страница 28: ...ith another one of equal value and characteristics at no cost to the buyer The warranty does not cover consumables and or components subject to wear such as batteries fuses etc and failures caused by...

Отзывы: