57
Roller replacement
-
After selecting the roller according to the table, the roller must be mounted in the metering unit.
1. With the full hopper, slide the slider over the dispenser (9).
2. Remove the screws (6) on the side cover of the metering roller (1).
3. Remove the roller (3) with drive shaft (5) and the side lid (1).
4. Remove the cotter pin (7).
5. Remove the secure ring (2) and cover washers (4)
6. Pull out the shaft (5) roller and mount it on a new roller. Keep the washers (4) on both sides of
the roller!
7. Secure the roller (3) with secure rings (2)
8. Insert the roller (3) into the dispenser.
9. Replace the side cover (1) and tighten the screws (6).
10. Secure with a cotter pin (7) (the first hole on the shaft).
11. Pull out the slider (8) and secure him to be sure that dispenser seals.
-
After each roller change, the trowel settings and the centered operation of the roller must be checked.
1
Side cover of the dosing roller
6
Screws
2
Secure ring
7
Cotter pin
3
Dosing roller
8
Closing slider in open position
4
Cover pad
9
Closing slider in closed position
5
Dosing roller shaft
8
9
1
6
7
3
5
4
2
Содержание FALCON PRO