background image

FarmChem |  www.FarmChem.com

800.247.1854  |  FarmChem

3

TECHNICAL DETAILS

Item no.

DCM-01

Flow range

0.3-9.2 GPM

Operating pressure range

7-1500 PSI

Operating temperature

Max. 140°F

Accuracy

±0.5%

Power source

ER14250 3.6V Battery

INSTALLATION

Typical installation

The installation shown below is only a guide. The components shown ae typical; 

however, it is not a complete system design. Contact your distributor for assistance 

in designing a system to suit your particular needs.

Pre-Installation Procedure

Relieve the pressure

1. 

Close the fluid shut-off valve

2. 

Ground the hose and reel or console. Do not use PTFE tape on the pipe joints; it 

may cause a loss of ground across the pipe joint

Installation Procedure

WARNING 

To reduce the risk of serious injury whenever you are instructed to relieve 

pressure, always follow this pressure relief procedure 

WARNING 

If this is a new installation, or if the oil in the lines is contaminated, flush 

the lines before you install the dispense valve.

Содержание APX Industrial DCM-01

Страница 1: ...Manual 800 247 1854 www FarmChem com DCM 01 Digital Manual Meter...

Страница 2: ...e electrical and safety regulations INJECTION HAZARD Spray from the valve leaks or ruptured components can inject fluid into your body and cause serious injury including the need for amputation Fluid...

Страница 3: ...for assistance in designing a system to suit your particular needs Pre Installation Procedure Relieve the pressure 1 Close the fluid shut off valve 2 Ground the hose and reel or console Do not use PTF...

Страница 4: ...sening the 4 swivel nut then by turn ing the nozzle to your desired position and tightening the nut Existing Installation 1 Relieve the pressure 2 Loosen and disconnect the hose from the old dispense...

Страница 5: ...essor Follow manufacturer s recommendations Fluid supply container Follow your local code To maintain grounding continuity when flushing or relieving pressure always hold a metal part of the valve fir...

Страница 6: ...s the container from the bottom Trigger the gun slowly so the fluid immediately covers the tip of the dispense valve To activate the digital display Press the RESET key pad to clear the meter before s...

Страница 7: ...ous injury including fluid injection never exceed the maximum working pressure of the valve you are using or of the low est rated component in your system DISPENSING PROCEDURE NOTE Before you begin ma...

Страница 8: ...FarmChem www FarmChem com 8 EXPLODED AND PARTS LIST...

Страница 9: ...zle MT10001 Manual tip MT10002 Auto tip MT10003 Semi auto tip Wearing parts Code Name Quantity 1 5 O ring 2 1 7 Washer flat 2 1 10 Seat 1 1 13 Filter 1 3 1 O ring 1 Code Name Quantity 3 5 Main circuit...

Страница 10: ...ge or obstructions and replace if damaged 2 If the problem remains contact your distributor for repair or replacement Valve leaks O rings or valve seat are worn or damaged 1 Replace the o rings and or...

Страница 11: ...800 247 1854 FarmChem 11...

Страница 12: ......

Отзывы: