To change the measurement units (L/GAL/PT/QT meter only)
•
Move the flashing display to Area 2 by pressing MENU, then press MENU again
to choose measurement
•
Press MENU for over three seconds to exit the setting mode
CAUTION
•
To be sure the proper amount of fluid is dispensed, always use
the same measurement unit for a particular fluid. Units should be
changed only by authorized employees.
•
To verify the accuracy of a digital meter, use a clean, calibrated
container. If using a single container, be sure to clean it after each
dispense
•
Have pump air pressure at the lowest possible setting for dispensing
fluid
•
Put the tip of the nozzle at the bottom of the calibrated container
•
If the tip of the dispense valve does not reach the bottom of the
calibrated container, use a length of plastic tubing over the tip of
the nozzle to ensure liquid enters the container from the bottom
•
Trigger the gun slowly so the fluid immediately covers the tip of the
dispense valve
To activate the digital display
Press the RESET key pad to clear the meter before starting a new dispense cycle.
This is the best way to activate the meter, because it also clears the quantity of the
last dispense cycle.
The digital display can also be activated by pressing the MENU key pad or by run
-
ning fluid through the meter.
Calibrating automatically
•
Press the RESET key for one second and area 1 shows .000 GAL
•
Keep running fluid through the meter. The display will show a value as *.**
GAL. Press the MENU key for three seconds and the meter will enter instrument
calibration mode
•
Press MENU to move from the selected number, then press RESET to choose a
number. Enter the fluid volume and press MENU again for three seconds.
Show current correction factor
•
Press MENU and RESET at the same time to show the current correction factor.
This number can be reset
Reset the resettlement total
•
Press MENU for 10 seconds. The accumulated total will be reset to “0”