INTERCOMS CONNECTED TO 1 EXTERNAL DOOR STATION
Q.ty
Article
Description
...
KM 810W
Compact series intercom with 1 call button
...
ST 720W
Studio series modular intercom
...
PT 510EW
Project series intercom with 1 call button
...
PT 526EW
Project series modular intercom
1
PRS240
Power supply with electronic ringing generator
1
PA **
Door release push-button (optional)
1
SE **
Electric door lock (12VAC-1A)
Door station series Mody (for right item set see on pages 16÷19)
1 row
2 row
...
MD71÷74
MD71÷74
Module frames with back box
1
MD10-11-12
MD10-122-124 Modules for electric door speaker
...
MD21 ÷ 24
MD222 ÷ 228
Button modules
...
MD20 - 50
MD20 - 50
Blank and info modules
1
MD82 ÷ 812
MD82 ÷ 812
Hood covers
1
MD92 ÷ 912*
MD92 ÷ 912*
Rain shelters with module frames
1
MD30
MD30
Electric door speaker (amplifier)
Door station series Matrix (for right item set see on pages 24 and 25)
...
MA71÷73
Module frames with back box
1
MA10P-11P-12P
Modules with integrated audio amplifier
...
MA20-22-24
Blank and button modules
...
MA61÷63
Front frames
...
MA91 ÷ 93 *
Rain shelters with module frames
Door station series Profilo (for right item set see on pages 28 and 29)
...
PL71÷73
Module frames with back box
1
PL10P-11P-12P
Modules with integrated audio amplifier
...
PL20 ÷ 24
Blank and button modules
... Refers to number of users.
* Rain shelters are used instead of back boxes and hood covers.
** Articles not supplied by ACI Farfisa.
Working instructions. See page 36.
Notes
- For the connection of name-plate lamps, read notes 6, 7 and 8 of the installation instructions on page 35.
- For wires dimensioning refer to the installation recommendations and table on page 35.
- Telephones can be used instead of intercoms (see “telecommunication” section).
- For other types of push-button panels see pages 30 and 31 or the general catalogue.
S
T
-
P
T
-
K
M
PA
SE
230V
127V
0
PRS240
X3
X2
xn
MD7.
MD100
MD200
MD2.
RP100
RP200
1
2
C+
X
C
1
2
UP11
UP100
UP12
UP200
P2
P1
Application diagram
When using MD100, MD200, RP100, RP200 and UP
amplified external door stations, place this diagram on the
diagram on page 39 and line it up with the riser.
One or two-way systems can be realized with RP and UP
series. As regards the Mody series, multi-family systems
can be realized by adding the required quantity of button
modules.
Warning.
- Cut jumper W1 in the RP100 and RP200 external door
PRS240
9
9
FP
FP
7
PT526E
PT510E
C+
ST720
KM810
Floor call
This work diagram allows for differ-
entiating the floor-call from the call
from the push-button panel.
stations.
- In UP series external door stations
do not connect and insulate the yel-
low wire.
- For alternate
current wires
refer to note 6
of the installa-
tion instructions
on page 35.
Floor-button
Floor-button