162
(MT11 - Gb2006)
Si 46MO/7
I
NTERCOMS *
V
IDEOINTERCOMS
*
T
ELECOMMUNICA
TION
VIDEO INTERCOM SYSTEM WITH ONE-WAY SECONDARY DOOR STATIONS ONLY AUDIO AND 1 MAIN COMMON VIDEO STATION
(multiple entrance)
Q.ty
Article
Description
...
WB8600
Compact videointercom Flat + bracket
...
8083
Compact videoin b back box
...
WB8600
Compact videointercom bracket
...
WB7100
Studio series m bracket
...
WB700
Studio series in bracket
...
DV2-4
Video distributor
1
1281
Power supply
1
1282E
Timer
X
1473
Exchanger
X
PRS240
Power supply
X
1471
Relay unit
1+...
476
Video distributor-amplifier
1+X
PA **
Door release button (optional)
1+X
SE **
Electric door lock (12Vac-1A)
Mody series external door station (for the composition see pages 96÷99)
1 row
2 row
...
MD72÷74
MD72÷74
Back boxes and module frames
X
MD71
-
Back box and module frames
X
MD11
-
Module for electric door speaker
1
MD10-11-12
MD10-122-124 Modules for electric door speaker
...
MD21 ÷ 24
MD222 ÷ 228
Button modules
...
MD20 - 50
MD20 - 50
Blank and info modules
1+X
MD82 ÷ 812
MD82 ÷ 812
Hood covers
1+X
MD92 ÷ 912*
MD92 ÷ 912*
Rain shelters and module frames
1+X
MD30
MD30
Electric door speaker (amplifier)
1
MD41
MD41
Camera
Matrix series external door station (for the composition see pages 102÷103)
...
MA72-73
Back boxes and module frames
X
MA71
Back box and module frames
...
MA62-63
Front frames
X
MA61
Front frame
...
MA20-22-24
Blank and button modules
X
MA11P
Module with audio amplifier
1
MA42-43
Cameras with integrated audio amplifier
...
MA91-92-93*
Rain shelters and module frames
Profilo series external door station
(for the composition see pages 106÷107)
...
PL71-72-73
Back boxes and module frames
X
PL71
Back box and module frames
...
PL20÷24
Blank and button modules
X
MA11P
Modules with audio amplifier
1
PL40P÷42P
Cameras with integrated audio amplifier
Connection of two door locks, of which the
secondary is always activable, in a system with
multiple entrance
For this option it is necessary to
install a diode (100V-1A; type
1N4007) between terminals 7
(cathode) and 7a (anode) of
every secondary exchanger.
7a
7
1473
3
13
7a
8b 9b 10b 7b
PA
SE
230V
127V
0
I
PRS240
1471
MD71
MD100
C+
6
5
1
3
2
1
X
8a
9a
2
1
6
5
4
7 12 8
9 10
Connection of the MD100 amplified external door sta-
tion to the secondary door station instead of electric
door speaker MD30 and module MD11.
1473
Connection of 1281E power supply-timer in-
stead of 1281 plus 1282E
By adding 1281E to the schematic on page 163
instead of 1281 plus 1282E, the system working
will modify as follows:
- switching-OFF at the end of the timing only
Power supply-timer of the main entrance
J1
1 2 3
J1
JP2
1
10
3
2
1
J1
3
2
1
Compact
Studio
230V
127V
0
1281E
S
F 3+
C+
4
X
H
5
... Refers to number of users.
X Refers to number of secondary door stations.
* The rain shelter is used in the place of the back box and hood cover.
** Articles not supplied by ACI Farfisa.
Working instructions. See page 115. By making the call from the secondary
audio station, the video intercom remains switched OFF.
Notes
- For the connection of name plate lamps read notes 6, 7 and 8 of the installation
instructions on page 111.
- Connect the video intercom terminal 4 (wire shown with dotted line) if the
control switch on from the main door station is required.
- To install a colour system, the ST7100CW video intercoms and the MD41C,
MA42C, MA43C, PL40PC, PL41PC or PL42PC camera must be used.
- For wires dimensioning and video connection refer to the installation instruc-
tions and table on pages 111÷113.
- DV.. distributors can be used instead of the video distributors 476 by adding
a power supply wire (from + to terminal 8 of every video intercom).
- Telephones can be used instead of intercoms (see “telecommunication”
section).
- On video intercom
brackets you must
move jumper J1 from
position 2-3 to 1-2. If
the private conversa-
tion is necessary,
use the Si46MO/5
diagram.