background image

151

(MT11 - Gb2006)

Si 46MO/1

VIDEO INTERCOM SYSTEM WITH SECONDARY VIDEO STATIONS AND 1 MAIN COMMON VIDEO STATION (multiple entrance)

I

NTERCOMS     *   

 

V

IDEOINTERCOMS

    *

    

T

ELECOMMUNICA

TION

476

OUT2
OUT3
OUT4
OUT5

OUT

OUT

OUT

OUT

“ A ”

“ B ”

PA

PA

IN

IN

IN

IN

IN

IN

IN

IN

75

75

DV2

DV4

DV2

DV4

DV2

DV4

DV2

DV4

10a

9a
8a

10a

9a
8a

“ C - D - .. ”

230V

230V

230V

127V

127V

127V

0

0

0

F

F

S

S

3+

3+

1282E

1282E

1282E

I

A

SE

1

1

5

5

7a

7a

12

12

11

11

7

7

10

10

9

9

8

8

6

2

12a
11a

6

2

12a
11a

F

14

OUT1

PA

4

4

7

7

3D

3D

I

I

xn(C)

x1(C)

xn(B)

xn(A)

xn(A)

Xn(B)

1281

1281

1273TV

1273TV

1281

“ C - D - .. ”

4 (C)

8
V

M

F
H
1
2
3
4
5

9M
9R

PC

P

1C

8
V

M

F
H
1
2
3
4
5

9M
9R

PC

P

1C

8
V

M

F
H
1
2
3
4
5

9M
9R

PC

P

1C

8
V

M

F
H
1
2
3
4
5

9M
9R

PC

P

1C

MD30

MD41

H

IV

H

IV

A

A

IV

A
H

A

A

WB7100

+ST720+WB700

WB7100

+ST720+WB700

WB7100

+ST720+WB700

WB7100

+ST720+WB700

WB8600

8083

WB8600

WB8600

8083

WB8600

WB8600

8083

WB8600

WB8600

8083

WB8600

1D

1D

2D

2D

1

2

5

C+

X

H

SE

SE

Xn(A)

Xn(B)

MD30

MD30

MD41

MD41

H
V
M

H
V
M

H
V
M

H
V
M

4
3
2
1

4
3
2
1

4
3
2
1

P

P

P

P

P

P

P

P

P

P

C

C

C

C

C

A

A

A

PL4.P

PL4.P

H
V
M

H
V
M

4
3
2
1

4
3
2
1

IN

S

F 3+ 3D C+ 2

X

H

5

4
3
2
1

4

4

3

3

12b

12b

11b

11b

10b

10b

7b

7b

9b

9b

8b

8b

MA4.

Mody

Mody

Mody

Matrix

Matrix

Matrix

Profilo

Profilo

Profilo

PL4.P

MA4.

MA4.

1

2

5

C+

X

H

Содержание ST 4231

Страница 1: ...1 1 STUDIO PROJECT 9 8 7 5 3 4 2 9 8 7 5 3 4 2 a 7 7a a 8 9a 9 8 7 5 3 TECHNICAL MANUAL 2006 ELECTRONIC CALL SYSTEMS COMPACT...

Страница 2: ...and video intercom system must be kept separate from the mains or any other electrical installation as required by International Safety Standards WARNINGS An all pole mains switch with a contact separ...

Страница 3: ...dules Installation instructions Installation diagrams Telecommunication Internal stations Intercom telephone interface Electronic PABX Installation instructions Installation diagrams Intercom videoint...

Страница 4: ...The interface can be a stand alone product art FT11D or an interface board to be installed inside the FT105P or FT208P electronic PABX art ES60 or ES65 Internalstationscanuse astandardtelephoneinwhich...

Страница 5: ...ideo memory 1 1 1 2 1 2 1 Video intercom telephone with video memory 1 1 1 2 1 2 1 Digital video intercom with video memory 1 1 1 1 2 1 2 1 COMPOSITION BOARD OF STUDIO SERIES INTERNAL STATIONS Or TA72...

Страница 6: ...ked at paying attention to the type of installation single electronic call common electronic or alternate current call from door station The installation diagram to use 2 3 4 6 or 7 intercoms should b...

Страница 7: ...atecurrent Si 211L 5S 5 intercommunicating intercoms connected to 1 external door station with common call Si 225L 5 5 intercommunicating intercoms connected to 2 external door stations with single ca...

Страница 8: ...resent in the JP2 connector 9 electronic call input INTERNAL STATIONS P1 P5 P7 P6 1 5 6 7 3 2 5 1 9 0 8 7 6 5 4 3 2 1 JP2 S T U D I O INTERCOMS Electronic call systems can use all intercoms of the Com...

Страница 9: ...es 9 electronic call input without resistive load 3 ground Exampleofswitchmoduleapplicationtodeac tivate the intercom call S T U D I O NA NC C 9 3 EC ST 704 Additionalloudspeaker Itallows to receive c...

Страница 10: ...e ST 720 intercoms It must be kept in mind that they cannot be installed all at the same time Below are some examples of pos sible combinations ST701 or ST702 or ST715 max 6 SR41 or SM50E or RL36 1 se...

Страница 11: ...S Compact series I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION C O M P A C T INTERNAL STATIONS 160 6 16 5 83 3 4 1 ST701 Mounting of the additional button ST701 2 9 1 3 5 7 W1 PT510EW White electronic...

Страница 12: ...Single button unit Note It is recommended to install the PT502 LED module and the PT515 switch module in the last 2 positions marked with and Toinstallthem theplasticbuttonslidesmustbe removed from t...

Страница 13: ...MD 804 MD 82 MD 86 MD 808 MD 84 MD 904 MD 93 MD 92 MD 91 Rain shelter with module frames Hood covers Module frames complete with back box PUSH BUTTONS MODY series EXTERNAL DOOR STATIONS MD 94 MD 96 MD...

Страница 14: ...els for ErreP R door stations by means of 299 1 adapter Terminals 1 audio receiver 2 audio transmitter 3 positive power supply 6 8Vdc 60mA 4 ground Dismountingandprotectionofnamela bels MD 222 2 call...

Страница 15: ...oltage input 9 10 connection to optional door lock release PUSH BUTTONS MODY series EXTERNAL DOOR STATIONS 12Vac 12Vdc door release relay 1 relay 2 PROXIMITY READER FOR ACCESS CONTROL FP52 This articl...

Страница 16: ...ion of cable bush between back boxes The cable bushes must be inserted before brickwork Openings for cables Flushmountingandcablesplacing Mountingofbuttonmodule Lower fixing of the module frame a Lowe...

Страница 17: ...lignmentofthepanel Hood covers Dismountingoftheframetopsidefromtherain shelter Fixingofthehoodcoverbetweenthebackbox and the module frame Rain shelter Modulesinsertionandwallfixingofrainshelter Mounti...

Страница 18: ...all buttons 13 call buttons 1 call button 2 call buttons 3callbuttons 10 call buttons 4 call buttons 5 call buttons 6 call buttons 7 call buttons 8 call buttons 13 call buttons 14 call buttons 11 call...

Страница 19: ...2 MD73 2 MD73 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 3 MD73 3 MD73 3 MD73 3 MD73 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 4 MD74 4 MD74 4 MD74 4 MD74 4 M...

Страница 20: ...call buttons 62 call buttons 68 call buttons 5 0 32 call buttons 22 call buttons 24callbuttons 26 call buttons 2 call buttons 4 call buttons 6 call buttons 20 call buttons 8 call buttons 10 call butt...

Страница 21: ...MD73 2 MD73 2 MD73 2 MD73 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 3 MD73 3 MD73 3 MD73 3 MD73 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 4 MD74 4 MD74 4 MD74...

Страница 22: ...beendevelopedto allowbothforhorizontalandverticalconfiguration MA 71 MA 72 MA 73 MA 61 MA 63 MA 62 Front frames Module frames complete with back box PUSH BUTTONS MATRIX series EXTERNAL DOOR STATIONS I...

Страница 23: ...open contact of relay 2 common contact of relay 2 normally closed contact of relay 1 1 normally open contact of relay 1 common contact of relay 1 ground or alternating voltage input positive or altern...

Страница 24: ...f the push button panel at a height of about 1 65m 5 5 from the floor keeping the front edges flush mounted and vertical to the finished plaster Insertion of spacers between back boxes Spacers and cab...

Страница 25: ...the electrical system it is recommended to insert the metal plate supplied with the product in the back box opening asshowninthefigure Theplateisusedtohooktheframe withpre assembledmodules Leavethepl...

Страница 26: ...ATIONS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION 6 call buttons 7 call buttons 10 call buttons 8 call buttons 12 call buttons M A T R I X 46 call buttons 44 call buttons 41 call buttons 40 call bu...

Страница 27: ...OR STATIONS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA20 1 MA20 1 MA20 1...

Страница 28: ...optimized size of modules allows for easy installation on the gage jamb Module frames complete with back box PUSH BUTTONS PROFILO series EXTERNAL DOOR STATIONS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNI...

Страница 29: ...al to the finished plaster Insertion of spacers between back boxes Spacers and cable bushing not supplied with the products must be inserted before brick work Openings for cables Flushmountingandcable...

Страница 30: ...S T ELECOMMUNICATION 10 call buttons 8 call buttons 12 call buttons P R O F I L O 46 call buttons 42 call buttons 41 call buttons 40 call buttons 37 call buttons 35 call buttons 22 call buttons 15 cal...

Страница 31: ...4 6 PL24 6 PL24 6 PL24 7 PL24 7 PL24 7 PL24 7 PL24 8 PL24 8 PL24 8 PL24 8 PL24 8 PL24 8 PL24 8 PL24 9 PL24 9 PL24 10 PL24 10 PL24 10 PL24 10 PL24 11 PL24 11 PL24 1 PL71 1 PL71 1 PL72 1 PL72 1 PL72 1 P...

Страница 32: ...installed on the wall with expansion plugs or on a wall box RP200 2 button amplified door station Technical data Power supply 13Vac Operating current 130mA Terminals 2 audio receiver 1 audio transmitt...

Страница 33: ...tercom and intercommunicating systems Complete with electric door speaker amplified in the two channels volume control of the receiving channel front panel in anodized alu miniumwithcallbutton Toinsta...

Страница 34: ...tput for alternate current calls from push button panels 13Vca 0 15A G Audio line receiver from intercoms 2 Audio line transmitter to intercoms D Audio line transmitter to electric door speaker C Audi...

Страница 35: ...oactivate deactivatemax 3 additional video power supplies Complete with electronic ringing generator for intercom munication Can be fixed on DIN bar or screwed to the wall with 2 expansion plugs Techn...

Страница 36: ...Vac 12 24Vdc Current consumption 0 05A Number of exchanges 1 Switching current 5A 50V Housing DIN 3 modules A Operating temperature 0 50 C Maximum permissible humidity 90 RH Terminals 1 Alternate curr...

Страница 37: ...e speaker unit 2 wires must originate from terminal minus sign of the power supply one for terminal4ofthespeakerunitandoneforthelamps orotherdevices poweredwithalternatecurrent 8 for name plate lamps...

Страница 38: ...versation module art SM50Eineveryintercom Afterthecall theuserhasabout 30 seconds to lift handset and answer There is no time limit for the privateconversation Whenthehandsetisreplacedthesystemreturns...

Страница 39: ...esindicatedinthepower Nothing at all is working Absenceofmainvoltage Short circuitorover loadoftheterminalsofthepowersupplyoutput Faultypowersupply The lock does not work Faulty lock Faulty door relea...

Страница 40: ...amplifier PL20 24 Blankandbuttonmodules Refers to number of users Rain shelters are used instead of back boxes and hood covers Articles not supplied by ACI Farfisa Working instructions See page 36 Not...

Страница 41: ...OMS CONNECTED TO 1 EXTERNAL DOOR STATION I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION S T P T K M xn 1 2 9 3 0 5 1 2 9 3 0 5 PA SE 230V 127V 0 PRS240 C ST720 PT526E PT510E 1 2 3 4 xn P P P C A x2 1 2...

Страница 42: ...moduleframes Door station series Profilo for right item set see on pages 28 and 29 PL71 73 Module frames with back box 1 PL10P 11P 12P Modules with integrated audio amplifier PL20 24 Blankandbuttonmod...

Страница 43: ...ERCOMS T ELECOMMUNICATION S T P T K M xn 230V 127V 0 PRS240 9T 1 5 7 C ST720 ST720 PT526E PT526E PT510E PT510E B C 9 B C 9 1 2 9 3 1 2 9 3 1 2 9 3 0 5 1 2 9 3 0 5 1 2 9 3 7 5 1 2 9 3 7 5 1 2 9 3 0 5 1...

Страница 44: ...lifier MA20 22 24 Blankandbuttonmodules MA61 63 Frontframes MA91 93 Rainshelterswithmoduleframes Door station series Profilo for right item set see on pages 28 and 29 PL71 73 Module frames with back b...

Страница 45: ...43 MT11 Gb2006 Si 22MO 1 INTERCOMS CONNECTED TO 2 AUTOMATICALLY SWITCHED EXTERNAL DOOR STATIONS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION S T P T K M...

Страница 46: ...20 22 24 Blankandbuttonmodules MA61 63 Frontframes MA91 93 Rainshelterswithmoduleframes Door station series Profilo for right item set see on pages 28 and 29 PL71 73 Module frames with back box 3 PL10...

Страница 47: ...45 MT11 Gb2006 Si 23MO 1 INTERCOMS CONNECTED TO 3 AUTOMATICALLY SWITCHED EXTERNAL DOOR STATIONS I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION S T P T K M...

Страница 48: ...kandbuttonmodules S T P T K M Floor call This work diagram allows for differ entiating the floor call from the call from the push button panel Refers to number of users X Refers to the number of stair...

Страница 49: ...230V 230V 127V 127V 0 0 7b 3 3 6 4 4 9a 8a 5 5 7a 7 7 8 8 9 9 8b 9b PRS240 PRS240 1473 1473 C C xn A xn B 230V 127V 0 PRS220 1 2 3 4 1 2 8b 9b 1 2 7b 6 9a 8a 7a A B C D xn A Xn B 1 2 9 3 0 5 1 2 9 3 0...

Страница 50: ...nt wires refer to note 6 of the installation instructions on page 35 Q ty Article Description KM 810W Compact series intercom with 1 call button ST 720W Studio series modular intercom PT 510EW Project...

Страница 51: ...PA x N x C PA PA SE SE 230V 230V 127V 127V 0 0 7b 3 3 6 4 4 9a 8a 5 5 7a 7 7 8 8 9 9 8b 9b PRS240 PRS240 1473 1473 C C 230V 127V 0 PRS240 1 2 3 4 1 2 8b 9b 1 2 7b 6 9a 8a 7a A B C D 1 2 9 3 0 5 1 2 9...

Страница 52: ...lankandbuttonmodules S T P T K M Floor call This work diagram allows for differ entiating the floor call from the call from the push button panel Refers to number of users X Refers to the number of st...

Страница 53: ...SE 6 4 4 9a 5 5 8a 7 7 7a 8 8 9 9 PA PA xn C x1 C xn B xn A xn A Xn B 1473 1473 3 C PA PA SE SE 230V 230V 127V 127V 0 0 7b 7b 3 3 6 6 4 4 7a 7a 8a 8a 5 5 9a 9a 7 7 8 8 9 9 PRS240 PRS240 1473 1473 C C...

Страница 54: ...3 6 3 0 4 4 12 4 4 5 5 20 5 10 6 6 30 6 18 7 7 42 7 28 8 8 40 9 9 54 10 10 70 11 11 88 Si 200L 7 I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION PT510E 5 3 1 9 2 7 W1 7 1 3 5 2 0 9 P1 P2 P3 W1 P1 PT526...

Страница 55: ...T11 Gb2006 I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION S T P T K M Si 200L 11 STUDIO series INTERCOMMUNICATING INTERCOMS 2 to 7 users PROJECT series INTERCOMMUNICATING INTERCOMS 2 to 11 users Si 200...

Страница 56: ...upon request Q ty Article Description ST 720W Studio series modular intercom ST 701 Singlebuttonunit PT526EW Project series modular intercom PT501 Singlebuttonunit 1 PRS226E Powersupply switcher 1 PA...

Страница 57: ...CT1 CT2 CT3 CT4 CT5 1 2 3 4 230V 127V 0 G 2 7 C D Y PRS226E 1 2 3 5 P1 C 9 C P2 C P3 C P4 1 2 3 5 P1 C P2 C P3 C 9 C P4 1 2 3 5 P1 C P2 C 9 C P3 C P4 P1 C P2 C P3 C P4 C 9 1 2 3 5 1 2 3 5 9 C P1 C P2...

Страница 58: ...h integrated audio amplifier 1 MA61 Frontframe 1 MA91 Rainshelterwithmoduleframes Door station series Profilo 1 PL71 Module frames with back box 1 PL11P Module with integrated audio amplifier Refers t...

Страница 59: ...ST720 ST701 SR41 ST720 ST701 SR41 ST720 ST701 SR41 ST720 ST701 SR41 PT526E PT501 SR41 PT526E PT501 SR41 PT526E PT501 SR41 PT526E PT501 SR41 PT526E PT501 SR41 1 2 3 4 SR41 1 2 4 3 3 5 P1 C P2 C P3 C P...

Страница 60: ...U D I O PA SE MD71 MD100 1 2 230V 127V 0 G 2 7 X D Y PRS226E C RP100 C 1 2 UP11 UP100 P2 P1 Application diagram When using MD100 RP100 UP11 and UP100 amplified external door stations place this diagra...

Страница 61: ...CT3 CT4 CT5 ST720 ST701 ST704 ST720 ST701 ST704 ST720 ST701 ST704 ST720 ST701 ST704 ST720 ST701 ST704 1 2 3 4 AP 1 2 9 3 5 3A P1 C 9A C P2 C P3 C P4 1 2 9 3 5 3A P1 C P2 C P3 C 9A C P4 1 2 9 3 5 3A P1...

Страница 62: ...ier PL20 24 Blankandbuttonmodules Refers to number of users see table Rain shelters are used instead of back boxes and hood covers Articles not supplied by ACI Farfisa Working instructions As the basi...

Страница 63: ...C P3 C P4 1 2 3 5 P1 C P2 C P3 C 9 C P4 1 2 3 5 P1 C P2 C 9 C P3 C P4 P1 C P2 C P3 C P4 C 9 1 2 3 5 1 2 3 5 9 C P1 C P2 C P3 C P4 ST720 ST701 ST720 ST701 ST720 ST701 ST720 ST701 ST720 ST701 PT526E PT5...

Страница 64: ...basic system described on page 36 with the following variations The audio functions and door lock opening are automatically switched to the door station which has made the call and remain in this stat...

Страница 65: ...ST720 ST701 SR41 ST720 ST701 SR41 ST720 ST701 SR41 PT526E PT501 SR41 PT526E PT501 SR41 PT526E PT501 SR41 PT526E PT501 SR41 PT526E PT501 SR41 1 2 3 4 SR41 1 2 4 3 3 5 P1 C P2 C P3 C P4 C 9 1 2 4 3 3 5...

Страница 66: ...Refers to number of users see table Rain shelters are used instead of back boxes and hood covers Articles not supplied by ACI Farfisa Working instructions As the basic system described on page 36 with...

Страница 67: ...720 ST701 ST704 ST720 ST701 ST704 ST720 ST701 ST704 1 2 3 4 AP 1 2 9 3 5 3A P1 C 9A C P2 C P3 C P4 1 2 9 3 5 3A P1 C P2 C P3 C 9A C P4 1 2 9 3 5 3A P1 C P2 C 9A C P3 C P4 P1 C P2 C P3 C P4 C 9A 1 2 9...

Страница 68: ...er PL20 24 Blankandbuttonmodules Refers to number of users see table Rain shelters are used instead of back boxes and hood covers Articles not supplied by ACI Farfisa Working instructions As the basic...

Страница 69: ...P1 C P2 C P3 C 9 C P4 1 2 3 5 P1 C P2 C 9 C P3 C P4 P1 C P2 C P3 C P4 C 9 1 2 3 5 1 2 3 5 9 C P1 C P2 C P3 C P4 ST720 ST701 ST720 ST701 ST720 ST701 ST720 ST701 ST720 ST701 PT526E PT501 PT526E PT501 PT...

Страница 70: ...basic system described on page 36 with the following variations The audio functions and door lock opening are automatically switched to the door station which has made the call and remain in this stat...

Страница 71: ...SR41 PT526E PT501 SR41 PT526E PT501 SR41 PT526E PT501 SR41 PT526E PT501 SR41 PT526E PT501 SR41 1 2 3 4 SR41 1 2 4 3 3 5 P1 C P2 C P3 C P4 C 9 1 2 4 3 3 5 P1 C 9 C P2 C P3 C P4 1 2 4 3 3 5 9 C P1 C P2...

Страница 72: ...Refers to number of users see table Rain shelters are used instead of back boxes and hood covers Articles not supplied by ACI Farfisa Working instructions As the basic system described on page 36 with...

Страница 73: ...C A A A 1 2 3 4 1 2 3 4 8b 9b 7b 8a 9a 1 2 7a 3 4 5 7 8 9 6 1 2 3 4 230V 127V 0 CT1 CT2 CT3 CT4 CT5 ST720 ST701 ST704 ST720 ST701 ST704 ST720 ST701 ST704 ST720 ST701 ST704 ST720 ST701 ST704 1 2 3 4 A...

Страница 74: ...eframes Door station series Profilo for right item set see on pages 28 and 29 Secondary entrances X PL71 Module frames with back box X PL11P Module with audio amplifier Main entrance PL71 73 Module fr...

Страница 75: ...3 4 1 2 1 2 B A C D 4 3 2 1 4 3 2 1 CT1 CT1 CT2 CT2 CT3 1 1 2 1 2 9 3 5 3A P1 C P2 C 9A 1 2 9 3 5 3A P1 C 9A 230V 230V 127V 127V 0 0 Y Y 4 4 PRS226E PRS226E G G 2 2 7 7 4b 4b C C D D 9 9 3 3 8 8 9 9...

Страница 76: ...501 PT526E PT501 PT526E PT501 APPLICATION DIAGRAMS FOR INTERCOMMUNICATING SYSTEM WITH SINGLE CALL FROM EXTERNAL STATION To match with diagrams Si 215L 5 Si 225L 5 Si 235L 5 S T P T K M to power supply...

Страница 77: ...C P2 C P3 C P4 C 9 C P5 C P6 1 2 3 5 P1 C P2 C P3 C P4 C P5 C 9 C P6 P1 C P2 C P3 C P4 C P5 C P6 C 9 1 2 3 5 x2 x3 x4 x5 x6 xn 1 2 3 5 9 C P1 C P2 C P3 C P4 C P5 C P6 ST720 ST701 ST720 ST701 ST720 ST...

Страница 78: ...MON ALTERNATE CURRENT CALL FROM EXTER NAL STATION AND ELECTRONIC CALL FOR EXTENSIONS To match with diagrams Si 211L 5 Si 221L 5 Si 231L 5 Si 261L 1S S T P T K M to power supply to power supply to powe...

Страница 79: ...5 P1 C P2 C P3 C P4 C P5 C 9 C P6 P1 C P2 C P3 C P4 C P5 C P6 C 9 1 2 4 3 3 5 1 2 4 3 3 5 9 C P1 C P2 C P3 C P4 C P5 C P6 ST720 ST701 SR41 ST720 ST701 SR41 ST720 ST701 SR41 ST720 ST701 SR41 ST720 ST70...

Страница 80: ...3 INTERCOMMUNICATING INTERCOMS 4 INTERCOMMUNICATING INTERCOMS 2 INTERCOMMUNICATING INTERCOMS APPLICATION DIAGRAMS FOR INTERCOMMUNICATING SYSTEMS WITH COMMON ELECTRONIC CALL FROM EXTERNAL STATION AND...

Страница 81: ...P4 P1 C P2 C P3 C P4 C 9A 1 2 9 3 5 3A 1 2 9 3 5 3A G 2 4B 9A C P1 C P2 C P3 C P4 RL37 9M 9R 9P 230V 127V 0 PRS210 7 Y 4 D C 9 5 INTERCOMMUNICATING INTERCOMS S T U D I O 230V 127V 0 PRS226E G 2 4B 7 Y...

Страница 82: ...OMMUNICATING INTERCOMS 5 INTERCOMMUNICATING INTERCOMS 230V 127V 0 PRS226E G 2 4B 7 A 4 D C 9 CT1 CT2 CT3 1 2 P1 C P2 C 9 P1 C 9 C P2 9 C P1 C P2 1 2 4 3 3 5 1 2 4 3 3 5 1 2 4 3 3 5 ST720 ST701 SR41 ST...

Страница 83: ...connected to three external door stations one of which only audio coaxial cable Si 43MO 4 Video intercom system connected to three external door stations of one which only audio twisted pair Si 43MO 5...

Страница 84: ...C Max permissible humidity 90 RH KM 8600W White colour videointercom with traditional cathode tube audio video privacy electronic microphone and terminal board for the connection to the wall bracket W...

Страница 85: ...y using 4 expansion plugs Fix the wall bracket at approximately 1 55 m distance from the floor aaaaaaaaaaa 2 16 5 59 16 1 128 5 5 16 3 132 5 4 7 4 11 Fix the bracket WB8600 to the back box 8083 with t...

Страница 86: ...power supply input 18 24Vdc X Negative balanced video signal input Y Positive balanced video signal input 1 Microphoneoutput 2 Speaker and automatic switching OFF input 3 Audioground 4 Control switchi...

Страница 87: ...onal TA700 or TA720 INSTALLATION The modularity of the Studio articles permits the realisation of different types of system Some of the possible compositions are illustrated below monitor only video i...

Страница 88: ...OINTERCOMS T ELECOMMUNICATION S T U D I O 5 Markthecolour terminalcombination onthejunctionbox 2 JP1 J2 JP4 H 1 2 3 9V 9R 9M 5 F 4 Y X P P 8 1 C C V M R9 JP5 J1 JP2 1 2 3 1 14 U1 1 10 3 2 1 U P U P 3...

Страница 89: ...T720 brackets WB7100 and WB700 and table adapters if required for the realisation of an internal station with video intercom functions Wall version JP1 J2 JP3 JP4 H 1 2 3 9V 9R 9M 5 F 4 Y X P P 8 1 C...

Страница 90: ...J2 H 1 2 3 9V 9R 9M 5 F 4 Y X P P 8 1 C C V M V R9 J1 JP2 1 2 3 1 14 U1 1 10 3 2 1 10 H 1 2 3 9V 9R 9M 5 J1 JP2 U1 1 10 3 2 1 6 HooktheintercombasetobracketWB700andconnecttheotherend oftheflatcabletoc...

Страница 91: ...pter TA7100 and hook the plastic frame to them 2 Passtheconnectioncablethroughthe hole in the back of the table adapter TA7100 and block it with the cable clamp 7 Hookthemonitorandintercomaccordingtot...

Страница 92: ...e input from video intercom DV 12Vdc voltage output to video distributor F Ground D Input supplementary command R Input supplementary command A Input supplementary command P Input supplementary comman...

Страница 93: ...com or telephone youmustpositionintheproperholesthe2plastictemplates contained in the packing before fixing bracket WB700 JP1 J2 JP3 JP4 H 1 2 3 9V 9R 9M 5 F 4 Y X P P 8 1 C C V M V R9 JP5 J1 JP2 1 2...

Страница 94: ...O YO XO DV 8 F F D R A P 8 Close the cover on the base of the video memory Table version 6 Pass the connection wires through the holeonthebaseandhookthebasetothe bracket 1 Applythe12anti sliprubberpad...

Страница 95: ...deo memory according to the instructions on pages 91 and 92 point 3 to 8 WhenconnectingthewiresontheterminalboardsofbracketWB7100 point7 markthecolour terminalcombinationonthejunctionbox 2 ST7100W WB7...

Страница 96: ...RS 210 OUT OUT DV ST7100W WB7100 ST720W WB700 ST701 ST7M32W WB700 DV VI M to the riser Multi way system Terminal 8 must be always connected even if the video distributor is not included in the sys tem...

Страница 97: ...amera according to the typeofinstallation Technical data MD41 MD41C MD41D Powersupply 21 3Vdc 21 3Vdc 15 21Vdc Operatingcurrent 0 3A 0 4A 0 3A Video signal output 1Vpp on 75 1Vpp on 75 1Vpp balanced V...

Страница 98: ...tons 30 call buttons 34 call buttons 5 0 5 0 16 call buttons 7 call buttons 5 0 5 0 11 call buttons 5 0 12 call buttons 1 call button 2 call buttons 3 call buttons 10 call buttons 4 call buttons 5 cal...

Страница 99: ...MD74 2 MD74 2 MD74 2 MD74 3 MD73 3 MD73 3 MD73 3 MD73 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 4 MD74 4 MD74 4 MD74 4 MD74 4 MD74 4 MD74 4 MD74 4 MD74 4 MD74...

Страница 100: ...ons 60 call buttons 68 call buttons 5 0 5 0 32 call buttons 28 call buttons 14 call buttons 20 call buttons 16 call buttons 18 call buttons 5 0 5 0 22 call buttons 24 call buttons 2 call buttons 4 cal...

Страница 101: ...1 MD73 1 MD73 2 MD72 2 MD72 2 MD72 2 MD72 2 MD73 2 MD73 2 MD73 2 MD73 2 MD73 2 MD73 2 MD73 2 MD73 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 M...

Страница 102: ...bs Video modules with integrated audio amplifier PUSH BUTTON PANELS EXTERNAL DOOR STATIONS Adjustments Youcanmanuallychangethecameraframing by unloosening and adjusting the horizontal and vertical scr...

Страница 103: ...ical system itisrecom mended to insert the metal plate supplied with the product in the back box opening as showninthefigure The plate is used to hooktheframewith pre assembled modules Leave the plate...

Страница 104: ...ons 7 call buttons 9 call buttons 6 call buttons 11 call buttons M A T R I X 45 call buttons 43 call buttons 40 call buttons 39 call buttons 37 call buttons 34 call buttons 21 call buttons 14 call but...

Страница 105: ...1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA20 1 MA20 1 MA20 1 MA20 1 MA20 1 MA20 1 MA20 1 MA20 2 MA20 2 MA20 2 MA20 2 MA20 1 MA20 1 MA20 1 MA...

Страница 106: ...mmon P1 Call push button V Video signal output coaxial cable M Video ground coaxial shield H Positive voltage input for camera 18 24Vdc L Negative power supply input for service Led L Positive power s...

Страница 107: ...ht or other direct or reflected light sources with high intensity do not hit the camera lens Insertion of spacers between back boxes Spacers and cable bushing not supplied with the products must be in...

Страница 108: ...ELECOMMUNICATION 10 call buttons 8 call buttons 12 call buttons P R O F I L O 46 call buttons 42 call buttons 41 call buttons 40 call buttons 37 call buttons 35 call buttons 22 call buttons 15 call bu...

Страница 109: ...24 7 PL24 7 PL24 7 PL24 7 PL24 8 PL24 8 PL24 8 PL24 8 PL24 8 PL24 8 PL24 8 PL24 9 PL24 9 PL24 10 PL24 10 PL24 10 PL24 10 PL24 11 PL24 11 PL24 1 PL71 1 PL71 1 PL72 1 PL72 1 PL72 1 PL72 1 PL73 1 PL73 1...

Страница 110: ...of the housing of the camera with the screw supplied a Make the connections as shown on the diagram Check that the jumper J1 is in position 2 3 power supply 21Vdc SYSTEMS WITH CCTV CAMERAS Installatio...

Страница 111: ...name plate light exchangers and timer con tinuous service 0 6A electric door lock and bells intermittent ser vice 1A Ground Continuous output 21Vdc 1A timed opera tion I Logic command input from timi...

Страница 112: ...TER COMMUNICATING SYSTEMS Itissuitableforvideointercomsystemswhere itisnecessarytohavetheintercommunicating service in different flats with privacy towards bothoutsideandotherusers Useoneart 2443 in e...

Страница 113: ...4 If the installation includes additional power supplies you must place them near the device to be powered Background noise To avoid possible background noise over the speech line it is advisable 5 n...

Страница 114: ...it Maximum 12 video distributors can be con nectedtogether DV2 DV4 VIDEO SIGNAL DISTRIBUTORS IN IN OUT 1 OUT 3 OUT 4 OUT 2 Monitors terminal board The resistance for terminate the video signal 75 is l...

Страница 115: ...natethe unusedoutputsonthe75 resist ance If more than one video distributor is to be used an extra power supply art 1281 is necessary Connection of art 476 as video amplifier for long distance systems...

Страница 116: ...TRIBUTORS They allow for the distribution of the video signal taken from the riser on 2 or 4 outputs They can be installed on the wall on a wall box with expansion plugs or it can be placed in the jun...

Страница 117: ...ross section of the wire corre sponds to what is indicated on page 111 and on the descriptions of each diagram Check that the connection of the wire corre sponds to the installation diagram Problem re...

Страница 118: ...f the control switching ON is necessary connect terminal 4 of the timer dashedwire For the connection of name plate lamps read notes 6 and 7 of the installation instructions on page 111 For wires dime...

Страница 119: ...ECTED TO ONE EXTERNAL DOOR STATION Video connection with twisted pair Si 411O 2 The following articles must be added to the list on page 116 1 RL37 Relaymodule 1 1281 Power supply 1 476 Videoamplifier...

Страница 120: ...er Refers to number of users Therainshelterisusedintheplaceofthebackboxand hoodcover Articles not supplied by ACI Farfisa Working instructions See page 115 Notes For the connection of name plate lamps...

Страница 121: ...DV4 H V M 230V 127V 0 1282E 4 3 2 1 2D 1D 3D 5 7 xn x2 xn 1281 MD30 MD41 4 8 V M F H 1 2 3 4 5 9M PC P 1C 9R 8 V M F H 1 2 3 4 5 9M PC P 1C 9R IN I A H V M 4 3 2 1 P P P C A MA4 IV H A F X S C 1 2 3 H...

Страница 122: ...back box and hood cover Articles not supplied by ACI Farfisa 1 For other types of cameras see page 108 Working instructions See page 115 Notes For the connection of name plate lamps read notes 6 7 and...

Страница 123: ...I A xn 8 X Y F H 1 2 3 4 5 9M 9R PC P 1C 8 X Y F H 1 2 3 4 5 9M R PC P 1C 9 PA SE DV2D DV4D DV2D DV4D X X F F H H Y Y 2x 75W X F H Y X F H Y X1 Y1 F H X1 Y1 F H 4 3 2 1 4 3 2 1 xn P P P C A x2 MD41D...

Страница 124: ...ntheplaceofthebackboxandhoodcover Articles not supplied by ACI Farfisa Working instructions See page 115 Notes For the connection of name plate lamps read notes 6 7 and 8 of the installation instructi...

Страница 125: ...0 KM8100 WB8600 KM8600 WB8600 8083 KM8800 WB8600 KM8100 WB8600 KM8600 WB8600 8083 KM8800 WB8600 ST720 SM50E B C 9 1 2 9 3 0 5 1 2 9 3 0 5 1 2 9 3 JP2 ST720 KM810 W1 KM810 SM50E 8 V M F H 1 2 3 4 5 9M...

Страница 126: ...installed with the monitor video intercom function the service is provided by the bracket WB7100 position 2 3 of jumper J1 Iftheuserhastheintercomfunctiononly youmust install the SM50E private convers...

Страница 127: ...F H H M V X Y H F X Y ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 F X S C 1 2 H 2D 1D 3D 5 7 4 3 IV H A ST720 SM50E B C 9 1 2 9 3 0 5 1 2 9 3 0 5 1 2 9 3 JP2 ST720 KM810 W1 KM810 SM50E MD41D M...

Страница 128: ...PL20 24 Blankandbuttonmodules 1 PL10P 11P 12P Modules with audio amplifier Refers to number of users The rain shelter is used in the place of the back box and hood cover Articles not supplied by ACI F...

Страница 129: ...DV4 DV2 DV4 230V 127V 0 1282E 4 3 2 1 2D 1D 3D 5 7 xn x2 xn 1281 4 8 V M F H 1 2 3 4 5 9M PC P 1C 9R 8 V M F H 1 2 3 4 5 9M PC P 1C 9R IN I A 4 3 2 1 P P P C A Mody IV H A F X S C 1 2 3 H ST7100 WB71...

Страница 130: ...audio amplifier Refers to number of users Therainshelterisusedintheplaceofthebackboxandhood cover Articles not supplied by ACI Farfisa Working instructions See page 115 Notes For the connection of nam...

Страница 131: ...V 0 1282E 2D 1D 3D 5 7 1281 4 I A IV H A 3 xn 8 X Y F H 1 2 3 4 5 9M 9R PC P 1C 8 X Y F H 1 2 3 4 5 9M R PC P 1C 9 DV2D DV4D DV2D DV4D X X F F H H Y Y 2x 75W X F H Y X1 Y1 F H X1 Y1 F H ST7100 WB7100...

Страница 132: ...back box and hood cover Articles not supplied by ACI Farfisa Working instructions See page 115 Notes For the connection of name plate lamps read notes 6 7 and 8 of the installation instructions on pa...

Страница 133: ...A H V M H V M 4 3 2 1 4 3 2 1 P P P P P P C C A A MA4 IV H A 3 10a 9a 8a 7a 12b 11b 3 6 1273TV H V M H V M 10b 9b 8b 7b 4 3 2 1 12a 11a F X 1 2 H S C xn ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 W...

Страница 134: ...ther types of cameras see page 108 Working instructions See page 115 Notes For the connection of name plate lamps read notes 6 7 and 8 of the installation instructions on page 111 If the control switc...

Страница 135: ...S C 12 11 10 2 1 7 5 4 9 8 PA PA SE SE 4 3 2 1 xn xn x2 x2 MD30 MD30 MD41D MD41D 4 3 2 1 4 3 2 1 P P P P P P C C A A V V CV01 CV01 M M F F H H M H V M H V Y Y X X F H Y X F H Y X 4 3 2 1 xn DV2D DV4D...

Страница 136: ...ifier Connectionof1281Epowersupply timer insteadof1281plus1282E By adding 1281E to the schematics on page 135 instead of 1281 plus 1282E the system working will modify as follows switching OFFattheend...

Страница 137: ...IN I A H V M 4 3 2 1 P P P C A IV H A 3 H V M 4 3 2 1 F X 1 2 H S C xn ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 KM8100 WB8600 KM8600 WB8600 8083 KM8800 WB8600 KM8100 WB8600 KM8600 WB8600 80...

Страница 138: ...adding 1281E to the schematics on page 137 instead of 1281 plus 1282E the system working will modify as follows switching OFFattheendofthetimingonly PA PA SE SE PRS210 1282E 1281E 2 2 1 5 1471 S 2 6 A...

Страница 139: ...SE SE 4 3 2 1 xn xn x2 x2 MD41D 4 3 2 1 4 3 2 1 P P P P P P C C A A V CV01 M F H M H V Y X F H Y X 4 3 2 1 xn DV2D DV4D DV2D DV4D Y Y F F H H X X 2x 75W Y F H X Y F H X ST7100 WB7100 ST720 WB700 ST710...

Страница 140: ...on ToactivatethecontrolswitchingONfromthevideointercomsonlywhen thesystemisinstandby itisnecessarytoinstalltwo2 exchangerelays type 1472 and connect them as shown on the diagram 1281E 1282E 1273TV DS1...

Страница 141: ...8600 WB8600 8083 KM8800 WB8600 KM8100 WB8600 KM8600 WB8600 8083 KM8800 WB8600 H V M H V M H V M 4 3 2 1 4 3 2 1 4 3 2 1 P P P P P P P P P C C C A A A IV H A 3 10a 9a 8a 7a 12b 11b 12b 11b 3 3 6 1273TV...

Страница 142: ...hing ON deactivation ToactivatethecontrolswitchingONfromthevideointercomsonlywhen thesystemisinstandby itisnecessarytoinstalltwo2 exchangerelays type 1472 and connect them as shown on the diagram 1281...

Страница 143: ...DV2D DV4D DV2D DV4D Y Y F F H H X X 2x 75W Y F H X Y F H X ST7100 WB7100 ST720 WB700 ST701 ST7100 WB7100 ST720 WB700 ST701 1 1 X1 Y1 F H 8 X Y F H 1 2 3 4 5 9M PC P C P1 1C 9R X1 Y1 F H 8 X Y F H 1 2...

Страница 144: ...Back boxes and module frames PL20 24 Blankandbuttonmodules 1 PL10P 11P 12P Modules with audio amplifier 2 PL40P 41P 42P Cameras with integrated audio amplifier 1281E 1282E 1273TV DS2 2 2 2 2 5 11 1472...

Страница 145: ...8600 KM8600 WB8600 8083 KM8800 WB8600 KM8100 WB8600 KM8600 WB8600 8083 KM8800 WB8600 H V M H V M 4 3 2 1 4 3 2 1 P P P P P P C C A A IV H A 3 10a 9a 8a 7a 12b 11b 3 6 1273TV H V M H V M 10b 9b 8b 7b 4...

Страница 146: ...audio amplifier 2 PL40P 41P 42P Cameras with integrated audio amplifier 2 CV01 Video signal converter 1281E 1282E 1273TV DS2 2 2 2 2 5 11 1472 2 3 2 7 2 13 4 P F H 3 6 Control switching ON deactivatio...

Страница 147: ...H S C xn DV2D DV4D DV2D DV4D Y Y F F H H X X 2x 75W Y F H X Y F H X ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 X1 Y1 F H 8 X Y F H 1 2 3 4 5 9M PC P 1C 9R X1 Y1 F H 8 X Y F H 1 2 3 4 5 9M PC...

Страница 148: ...sition see pages 106 107 PL71 72 73 Back boxes and module frames PL20 24 Blankandbuttonmodules 2 PL10P 11P 12P Modules with audio amplifier 1 PL40P 41P 42P Cameras with integrated audio amplifier Cont...

Страница 149: ...WB7100 ST720 WB700 KM8100 WB8600 KM8600 WB8600 8083 KM8800 WB8600 KM8100 WB8600 KM8600 WB8600 8083 KM8800 WB8600 H V M 4 3 2 1 4 3 2 1 P P P P P P C C A A IV H A 3 10a 7a 8b 9b 3 6 1473 H V M 7b 4 3 2...

Страница 150: ...2 PL10P 11P 12P Modules with audio amplifier 1 PL40P 41P 42P Cameras with integrated audio amplifier 1 CV01 Video signal converter Control switching ON deactivation To activate the control switching O...

Страница 151: ...D DV2D DV4D Y Y F F H H X X 2x 75W Y F H X Y F H X ST7100 WB7100 ST720 WB700 ST701 ST7100 WB7100 ST720 WB700 X1 Y1 F H 8 X Y F H 1 2 3 4 5 9M PC P 1C 9R X1 Y1 F H 8 X Y F H 1 2 3 4 5 9M PC P 1C 9R 4 3...

Страница 152: ...a Working instructions See page 115 Notes For the connection of name plate lamps read notes 6 7 and 8 of the installation instructions on page 111 Connectthevideointercomterminal4 wireshownwithdottedl...

Страница 153: ...8 V M F H 1 2 3 4 5 9M 9R PC P 1C 8 V M F H 1 2 3 4 5 9M 9R PC P 1C 8 V M F H 1 2 3 4 5 9M 9R PC P 1C MD30 MD41 H IV H IV A A IV A H A A ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB71...

Страница 154: ...tes For the connection of name plate lamps read notes 6 7 and 8 of the installation instructions on page 111 Connect the video intercom terminal 4 wire shown with dotted line if the control switch on...

Страница 155: ...IV H IV A A IV A H A A ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 1D 1D 2D 2D Xn A Xn B 4 3 2 1 4 3 2 1 4 3 2 1 P P P P P P P P P P C C C...

Страница 156: ...ith audio amplifier 1 PL40P 42P Cameras with integrated audio amplifier Refers to number of users X Refers to number of secondary door stations The rain shelter is used in the place of the back box an...

Страница 157: ...M F H 1 2 3 4 5 9M 9R PC P 1C 8 V M F H 1 2 3 4 5 9M 9R PC P 1C 8 V M F H 1 2 3 4 5 9M 9R PC P 1C MD41 H IV H IV A A IV A H A A ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720...

Страница 158: ...rs to number of users X Refers to number of secondary door stations The rain shelter is used in the place of the back box and hood cover Articles not supplied by ACI Farfisa 1 For other types of camer...

Страница 159: ...P 1C 8 X Y F H 1 2 3 4 5 9M 9R PC P 1C H IV H IV A A IV A H A A ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 1D 1D 2D 2D Xn A Xn B 4 3 2 1 4...

Страница 160: ...tall a diode 100V 1A type 1N4007 between terminals 7 cathode and 7a anode of every secondaryexchanger Control switching ON deactivation To activate the control switching ON from the inter comsonlywhen...

Страница 161: ...V M F H 1 2 3 4 5 9M 9R PC P 1C 8 V M F H 1 2 3 4 5 9M 9R PC P 1C H IV H IV A A IV A H A A ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 KM810...

Страница 162: ...ry secondaryexchanger Control switching ON deactivation To activate the control switching ON from the inter comsonlywhenthesystemisinstandby itisneces sarytoinstallarelay type1471or1472 andconnect it...

Страница 163: ...F H 1 2 3 4 5 9M 9R PC P 1C H IV H IV A A IV A H A A ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 1D 1D 2D 2D Xn A Xn B 4 3 2 1 4 3 2 1 4 3...

Страница 164: ...ated audio amplifier Connection of two door locks of which the secondaryisalwaysactivable inasystemwith multiple entrance Forthisoptionitisnecessaryto install a diode 100V 1A type 1N4007 between termi...

Страница 165: ...V M F H 1 2 3 4 5 9M 9R PC P 1C MD30 MD30 C C 6 6 IN F 14 5 5 1 1 3 3 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 KM8100 WB8600 KM8600 WB8600 8083 KM8800 WB8600 KM8100 WB8600 KM8600 WB8600 808...

Страница 166: ...converter H 1 2 3 J1 JP2 1 10 3 2 1 J1 1 2 3 Refers to number of users X Refers to number of secondary door stations The rain shelter is used in the place of the back box and hood cover Articles not...

Страница 167: ...C D 8 X Y F H 1 2 3 4 5 9M 9R 1C PC P 8 X Y F H 1 2 3 4 5 9M 9R 1C PC P 6 6 IV A H 3 3 13 13 7a 7a 8b 8b 9b 9b 10b 10b 7b 7b 8a 9a 2 1 8a 9a 2 1 5 5 1 1 3 3 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST...

Страница 168: ...The rain shelter is used in the place of the back box and hood cover Articles not supplied by ACI Farfisa Working instructions See page 115 Notes For the connection of name plate lamps read notes 6 7...

Страница 169: ...PC P 1C 8 V M F H 1 2 3 4 5 9M 9R PC P 1C MD41 H IV H IV A A IV A H D D A A ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 KM8100 WB8600 KM860...

Страница 170: ...pplied by ACI Farfisa 1 For other types of cameras see page 108 Working instructions See page 115 Notes For the connection of name plate lamps read notes 6 7 and 8 of the installation instructions on...

Страница 171: ...100 WB7100 ST720 WB700 DV2D DV4D DV2D DV4D DV2D DV4D DV2D DV4D Y Y Y Y Y Y H H H H H H F F F F F F X X X X X X 2x 75 2x 75 X1 Y1 F H X1 Y1 F H X1 Y1 F H X1 Y1 F H Y H F X Y H F X 1 5 7a 12 11 7 10 9 8...

Страница 172: ...f users X Refers to number of secondary door stations The rain shelter is used in the place of the back box and hood cover Articles not supplied by ACI Farfisa Working instructions See page 115 Notes...

Страница 173: ...9M 9R PC P 1C 8 V M F H 1 2 3 4 5 9M 9R PC P 1C H IV H IV A A IV A H D D A A ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 KM8100 WB8600 KM860...

Страница 174: ...X MA10P 11P 12P Modules with audio amplifier 2 PL40P 42P Cameras with integrated audio amplifier 7a 7 1273TV DS1 Refers to number of users X Refers to number of secondary door stations The rain shelte...

Страница 175: ...1 2 3 4 5 9M 9R PC P 1C 8 V M F H 1 2 3 4 5 9M 9R PC P 1C H IV H IV A A IV A H D D A A ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 ST7100 WB7100 ST720 WB700 KM8100 W...

Страница 176: ...V01 Video signal converter Refers to number of users X Refers to number of secondary door stations The rain shelter is used in the place of the back box and hood cover Articles not supplied by ACI Far...

Страница 177: ...x 75 X1 Y1 F H X1 Y1 F H X1 Y1 F H X1 Y1 F H Y H F X Y H F X 1 5 7a 12 11 7 10 9 8 1 5 7a 12 11 7 10 9 8 PA PA SE Xn A Xn B 4 3 2 1 4 3 2 1 10a 9a 8a 10a 9a 8a DV2D DV4D DV2D DV4D F H X Y X1 Y1 6 12a...

Страница 178: ...videointercom youmustcutthe75 resis tance R8 of the bracket and leave it only on the last video intercom H 1 2 3 J1 JP2 1 10 3 2 1 J1 1 2 3 JP3 JP4 Y X P V M V R8 R10 R7 R8 JP3 JP4 Y X P V M V R8 R10...

Страница 179: ...the two diagrams to obtain the intercommunicating service make the connections which have been drawn with a dashed line and move the jumper J1 of bracket WB7100 from position 2 3 to 1 2 Example by ma...

Страница 180: ...onnection of the floor call on an installation with 1281 power supply and 1282E timer Connection of the floor call on an installation with 1281E power supply timer Application on all one or multi way...

Страница 181: ...age 176 VC1 VC2 KM8100 WB8600 KM8600 WB8600 8083 KM8800 WB8600 230V 127V 0 1471 1281 2 5 6 8 V M F H 1 2 3 4 5 9M PC P 9R 3 8 V M F H 1 2 3 4 5 9M PC P 9R 230V 127V 0 RL37 1281 A I Xn IV 2443 D 9R 7 9...

Страница 182: ...TERCOM MUNICATING SERVICE VC1 ST7100 WB7100 ST720 WB700 ST701 CT2 CT1 1 2 3 5 9 3A 1 2 3 5 9 3A ST 704 P1 C P2 C 9A P1 C 9A C P2 9 C P1 C P2 ST720 ST701 ST704 ST720 ST701 ST704 1 2 8 V M F H 1 2 3 4 5...

Страница 183: ...ERCOMS WITH INTERCOMMUNI CATING SERVICE VC1 VC2 ST7100 WB7100 ST720 WB700 ST701 ST7100 WB7100 ST720 WB700 ST701 8 V M F H 1 2 3 4 5 9M PC P 1C 9R RL37 8 V M F H 1 2 3 4 5 9M PC P 1C 9R 9 C P1 C P2 C P...

Страница 184: ...C P3 P1 C P2 C 9 C P3 P1 C P2 C P3 C 9 9R 7 9M H B 9P VC1 ST7100 WB7100 ST720 WB700 ST701 8 V M F H 1 2 3 4 5 9M PC P 1C 9R 9 C P1 C P2 C P3 C P4 P1 C P2 C P3 C 9A C P4 P1 C P2 C 9A C P3 C P4 P1 C 9A...

Страница 185: ...B7100 ST720 WB700 ST701 ST7100 WB7100 ST720 WB700 ST701 8 V M F H 1 2 3 4 5 9M PC P 1C 9R 230V 127V 0 1281 A I 8 V M F H 1 2 3 4 5 9M PC P 1C 9R 9 C P1 C P2 C P3 C P4 P1 C P2 C 9 C P3 C P4 P1 C P2 C P...

Страница 186: ...5 9M PC P 1C 9R P1 C 9 C P2 C P3 C P4 RL37 9R 7 9M H IV B 9P Read notes 1 3 and 4 of page 176 I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION ONE WAY additional diagrams 5 VIDEO INTERCOMS WITH INTERCOMM...

Страница 187: ...9 C P2 C P3 C P4 C P5 P1 C P2 C 9 C P3 C P4 C P5 P1 C P2 C P3 C 9 C P4 C P5 P1 C P2 C P3 C P4 C 9 C P5 P1 C P2 C P3 C P4 C P5 C 9 9P 9R 7 9M H 9P Read notes 1 3 and 4 of page 176 3 VIDEO INTERCOMS AND...

Страница 188: ...C P5 C P6 ST720 ST701 1 2 3 4 5 6 D D D D D D 1 2 3 5 1 2 3 5 1 2 3 5 1 2 3 5 1 2 3 5 1 2 3 5 P1 C P2 C P3 C P4 C 9 C P5 C P6 IV B 9R 7 9M H 9P P1 C P2 C P3 C P4 C P5 C P6 C 9 D 100V 1A diode type 1N...

Страница 189: ...ST7100 WB7100 ST720 WB700 Xn CT1 ST 704 ST720 ST701 ST704 1 D GN30 2443 230V 230V 127V 127V 0 0 PRS210 PRS210 14 12 13a 12a 13 F S2 8 V M F H 1 2 3 4 5 9M PC P 1C 9R 1 2 3 5 9 3A P1 C 9A 1 VIDEO INTER...

Страница 190: ...P1 C P2 P1 C 9 C P2 230V 127V 0 1281 Xn D 2443 230V 127V 0 PRS210 14 12 13a 12a 13 F 8 V M F H 1 2 3 4 5 9M PC P 1C 9R 8 V M F H 1 2 3 4 5 9M PC P 1C 9R IV A I VC3 ST7100 WB7100 ST720 WB700 ST701 8 V...

Страница 191: ...ST7100 WB7100 ST720 WB700 ST701 ST7100 WB7100 ST720 WB700 ST701 ST7100 WB7100 ST720 WB700 ST701 8 V M F H 1 2 3 4 5 9M PC P 1C 9R 8 V M F H 1 2 3 4 5 9M PC P 1C 9R 230V 127V 0 1281 A I 8 V M F H 1 2...

Страница 192: ...12 13a 12a 13 F VC1 VC2 VC5 VC3 VC6 VC4 ST7100 WB7100 ST720 WB700 ST701 ST7100 WB7100 ST720 WB700 ST701 ST7100 WB7100 ST720 WB700 ST701 ST7100 WB7100 ST720 WB700 ST701 ST7100 WB7100 ST720 WB700 ST701...

Страница 193: ...way video intercom telephone system with telephone interface and connection to one external door station with twistedpair Si 411T 12 One way video intercom telephone system with PABX and connection t...

Страница 194: ...services Button for communication with external door station Memory buttons Keypad Key R or FLASH Programming key Repeat key Ringing volume adjustment Description FIXING ELEMENTS Wall version INSTALLA...

Страница 195: ...X FT105Por FT208P orL andL ofthetelephoneinterfaceFT11D Table version Apply the 4 anti slip rubber pads in their housings under the table adapter base Make the hole for the telephone cable Block the t...

Страница 196: ...o way installations with differentiated door locks activation of relays 3 and 4 etc See the PABX instructions on pages 208 and 209 Tochangeprogramming pick upthehandset press no tone is heard on the l...

Страница 197: ...set Replacethehandsetafterconversation Make a call Pick upthehandset Dialthenumber Replacethehandsetafterconversation Note If the telephone is connected to a Farfisa PABX s you must dial 0 81 or 82 to...

Страница 198: ...ymbol I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION S T U D I O JP1 J2 JP3 JP4 H 1 2 3 9V 9R 9M 5 F 4 Y X P P 8 1 C C V M V R9 JP5 J1 JP2 1 2 3 1 14 U1 1 10 3 2 1 Choosing the video connection with co...

Страница 199: ...3 2 1 1 Fix the bracket WB7100 to the wall with the 3 fixingpointsatapproximately1 55mdistance from the floor to the upper part of the bracket MONITOR ONLY Installation steps for monitor ST7100 or ST...

Страница 200: ...P2 1 2 3 1 14 U1 1 10 3 2 1 U P U P 3 Fix the bracket WB7100 with the 2 screwssupplied 4 Maketheconnectiontothebracket terminal board according to the in stallationdiagram 2 Passtheconnectioncablethro...

Страница 201: ...with video intercom telephone func tions Wall version 4 Pass the telephone cable through the space between the telephone and the bracket Pull the cable in such a way that the extra part of the cable f...

Страница 202: ...diagram 5 Hook the telephone to the bracket WB700 I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION INTERNAL STATIONS S T U D I O JP1 J2 H 1 2 3 9V 9R 9M 5 F 4 Y X P P 8 1 C C V M V R9 J1 JP2 1 2 3 1 14...

Страница 203: ...terminal combination on the junctionbox 2 1 Apply the 8 anti slip rubber pads in their housings under the base of the table adapters TA7100 and TA700 2 Passtheconnectioncablethroughthe hole in the ba...

Страница 204: ...2 TA700 table adapter for telephone and video memory Toinstallavideomemorymodulenexttothemonitorandtelephone you must insert the 2 plastic templates contained in the packing on the proper holes of the...

Страница 205: ...5 Screw the brackets WB7100 and WB700 on the table adapters 4 Screw the 4 metallic frames on the table adapters and hook the 2 plastic frames to them see drawing 4 on page 201 6 Hook the monitor and i...

Страница 206: ...t of relay INSTALLATION The intercom telephone interface FT11D in DIN housing 8 modules A can be installed in suitable electrical box provided with bar sup port in compliance with DIN 46277 standards...

Страница 207: ...monophase power supply Connect the protection device in parallel to pre vent it from being crossed by the operating cur rent This allows for connecting devices that ab sorbahighercurrentthanthecurren...

Страница 208: ...croprocessor control with recorded program Solid stateswitchingmatrix 2 wireinternaltelephonenetwork The other extension lines can also be used but in this case the use of the general call function is...

Страница 209: ...pair cables to reduce crosstalkproblems check that the ON OFF switch is OFF connectthewiresoftheexternallines1and2toterminalsURB1and URB2 URB1 for FT105P connect the wires of the telephones to DER41 D...

Страница 210: ...DER42 DER41 J204 IL COPERCHIO CAUTION TO PREVENT THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER RISCHIO DI SCOSSE ELET ATTENZIONE PER EVITARE TRICHE NON RIMUOVERE DANGER 4 2 3 1 CALLER ID URB2 URB1 G3...

Страница 211: ...user s needs and for setting the operating mode for the each indi vidual telephone connected to the PABX PROGRAMMING CAN ONLY BE CARRIED OUT FROM EXTEN SION 41 WhenswitchingitON thePABXisprogrammedfor...

Страница 212: ...is day 333310 night 333312 0 theextension isnotenabledtohaveconversationswiththeexter nalintercomstation isnotenabledtoactivaterelays door opener stair case lighting etc 1 theextension is enabled to h...

Страница 213: ...e call control tone wait for the D I S A post dialling tone dial 7 dial the password programmed for the specific external line dial the number of the relay to be activated 1 relay 1 2 relay 2 3 relay...

Страница 214: ...agram code Page reference Si21MO 1 39 Si22MO 1 43 Si23MO 1 45 Si26MO 1 47 Si26MO 2 49 Si27MO 1 51 Forinstallationinstructionsandwirecross section see page 35 VIDEO INTERCOM TELEPHONE SYSTEMS For the r...

Страница 215: ...hone with PABX FT208P ST7100 WB7100 ST720 WB700 8 V M F H 1 2 3 4 5 9M PC P 1C 9R to riser to riser to riser Video connections with TWISTED PAIR Traditional video intercom telephone Video intercom tel...

Страница 216: ...X C 1 2 UP11 UP100 UP12 UP200 P2 P1 Refers to number of users Rain shelters are used instead of back boxes and hood covers Articles not supplied by ACI Farfisa Working instructions See page 36 Notes I...

Страница 217: ...1 2 6a 3 5 ST740 WB700 230V L N URB1 URB2 FT11D 230V 230 127 0 L TIP L RING 1 2 6 3 5 ST740 WB700 PA SE 230V 127V 0 PRS240 C 1 2 3 4 xn P P P C A 1 2 3 4 Mody Matrix Profilo Si 21MT 1 MIXED INTERCOM...

Страница 218: ...Programming When using the interface FT11D with the telephone ST740 it is necessary to programme the buttons dedicated to the intercom functions see page 204 Note For wires dimensioning refer to the...

Страница 219: ...tallationinstructionsandtableon pages 111 113 Toinstallacoloursystem theST7100CWvideo intercoms and the MD41C MA43Cor PL41PC camera must be used Notes For wires dimensioning and video connec tion refe...

Страница 220: ...e phoneST740itisnecessarytoprogrammethe buttons dedicated to the intercom functions see page 204 Notes For wires dimensioning and video connection refertotheinstallationinstructionsandtableon pages 11...

Страница 221: ...ast video intercom For the video connection with twisted pair use the camera MD41D and read note 4 on page 158 or add the video converter CV01 see page 108 Toinstallacoloursystem theST7100CWvideointer...

Страница 222: ...y ACI Farfisa Notes If the maximum number of extensions is 5 you can use the PABX FT105P For the connection of name plate lamps read notes 6 7 and 8 of the installation instructions on page 111 Ifthec...

Страница 223: ...H 1 2 3 4 5 9M PC P 1C 9R FT11D 230V 230 127 0 TIP RING 6 1 2 3 5 L L xn ST7100 WB7100 ST740 WB700 FT208P ES60 ES65 230V L N URB1 URB2 8 V M F H 9M 4 DER41 DER43 DER45 DER47 DER42 DER44 DER46 DER48 6...

Страница 224: ...can use the PABX FT105P For the connection of name plate lamps read notes 6 7 and 8 of the installation instructions on page 111 IfthecontrolswitchingONisnecessary connectterminal4ofthetimer dashedwi...

Страница 225: ...RB1 URB2 8 X Y F H 9M 4 DER41 DER43 DER45 DER47 DER42 DER44 DER46 DER48 6b 6a 1 2 3 5 ST740 WB700 230V 127V 0 1282E 2D 1D 3D 5 7 1281 4 I A IV H A F X S C 1 2 3 H ST7100 WB7100 ST720 WB700 PA SE DV2D...

Страница 226: ...lampsreadnotes6 7and 8 of the installation instructions on page 111 IfthecontrolswitchingONisnecessary connectterminal4 of the timer dashed wire Toinstallacoloursystem theST7100CWvideointercoms and th...

Страница 227: ...0 WB700 ST740 WB700 FT208P ES60 ES65 230V L N URB2 URB1 ST7100 WB7100 ST740 WB700 OUT IN DV2 IN 8 V M F H 9M 4 8 V M F H 9M 4 ST740 WB700 ST740 WB700 PA SE H V M 230V 127V 0 1282E 4 3 2 1 2D 1D 3D 5 7...

Страница 228: ...rfisa Notes Fortheconnectionofnameplatelampsreadnotes6 7and 8 of the installation instructions on page 111 IfthecontrolswitchingONisnecessary connectterminal4 of the timer dashed wire Toinstallacolour...

Страница 229: ...281 4 I A 4 3 2 1 P P C A Mody Matrix IV H A 3 DER41 DER44 DER48 DER46 DER43 DER45 DER47 DER42 VC1b VC1a VC2b VC2a MD30 Profilo MD41D V CV01 M F H H M V X Y H F X Y MA4 PL4 P DV2D X F H Y X F H Y X1 Y...

Страница 230: ...ETS AND 4 INTERCOMMUNICATING TELEPHONES 8 V M F H 9M 4 ST7100 WB7100 ST740 WB700 ST7100 WB7100 ST740 WB700 ST7100 WB7100 ST740 WB700 ST7100 WB7100 ST740 WB700 ST740 WB700 230V 127V 0 1281 1471 I A 8 V...

Страница 231: ...I I A A 8 V M F H 9M 4 8 V M F H 9M 4 8 V M F H 9M 4 8 V M F H 9M 4 FT208P ES60 ES65 230V L N URB1 URB2 8 V M F H 9M 4 DER41 DER43 DER45 DER47 DER42 DER44 DER46 DER48 6b 6a 2 1 3 5 ST740 WB700 5 5 3...

Страница 232: ...S VIDEO INTERCOM TELEPHONE additional diagrams I NTERCOMS V IDEOINTERCOMS T ELECOMMUNICATION 1 PABX 6 VIDEO INTERCOM TELEPHONE SETS AND 2 INTERCOMMUNICATING TELEPHONES Attention the extensions of this...

Страница 233: ...i 26MR 1 Intercom system with secondary door stations and 1 main common station multiple entrance Si 411R 1 One wayvideointercomsystem Si 41MR 2 Multi way mixed intercom and video intercom system conn...

Страница 234: ...hat links the termi nals 3 and 7 tomaketheconnectionbetweenterminal7of the intercom and the minus of the private conversationmodule In all SM50 private conversation modules cut the resistance R1 W1 1...

Страница 235: ...o privacy between us ers it is necessary to add to each PT511E intercomtheprivateconversationmodule The intercom can communicate with the out side for an unlimited period only after having received th...

Страница 236: ...emperature 0 50 C Max permissible humidity 90 RH VIDEOINTERCOMS series COMPACT 1 2 Videointercom with out audio privacy 2 3 Videointercom with audio privacy Installation aaaaaaaaa Fix the bracket abou...

Страница 237: ...mperature 0 50 C Max permissible humidity 90 RH Terminals H Positive power supply input 18 24Vdc 0 35A F Ground X and Y Video signal input 10 Call audio reception transmission door releasing 4 Control...

Страница 238: ...tics and 6 infrared LED s front plate in anodized aluminium with break prooftransparentscreen horizontal verticalsweep Technical data Power supply 21 3Vdc Operating current 0 3A Output of balanced vid...

Страница 239: ...MD73 2 MD73 2 MD73 2 MD73 2 MD73 2 MD73 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 3 MD73 3 MD73 3 MD73 3 MD73 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 3 MD74 4 MD74...

Страница 240: ...2 MD72 2 MD72 2 MD72 2 MD72 2 MD73 2 MD73 2 MD73 2 MD73 2 MD73 2 MD73 2 MD73 2 MD73 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 2 MD74 3 MD73 3 MD73 3 MD73 3 MD73 3 MD74 3 MD74 3 MD74 3 MD74 3 MD...

Страница 241: ...d operation LED amplified door speaker Technical data Power supply 21 3Vdc Operating current 0 3A Output of balanced video signal Minimum illumination 2 lux Sensor CCD 1 4 B W Pixel number 291000 Hori...

Страница 242: ...A73 4 MA73 4 MA73 4 MA73 4 MA73 4 MA73 4 MA73 4 MA73 4 MA73 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA20 1 MA20 1 MA20 1 MA20...

Страница 243: ...MA73 4 MA73 4 MA73 4 MA73 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA22 1 MA20 1 MA20 1 MA20 1 MA20 1 MA20...

Страница 244: ...voltage input 21Vdc IV supplementarypowersupplyenabling C commoncontactofrelay NA normallyopencontactofrelay NC normallyclosedcontactofrelay 1P electroniccallinput 1M electronic call output enabled fr...

Страница 245: ...caldoorlocks Always use separate wires for alternate current power supplies 7 for name plate lamps to use an additional 12Vac transformer PRS210 type with suitable power consumption is 75mA for each l...

Страница 246: ...he intervention of a specialized technician is advisable The Contrast and Brightness adjustments being subject to the environ mental lighting conditions are accessible from the under neath by means of...

Страница 247: ...D CP A1 A1 FP FP A 1181E PRS210ED A Note Move the jumper J2 present inside the RL37D module from the position 1 2 to the 2 3 to have a different ringing sound 3 1 A1 3 1 A1 3 1 A1 PT511E PT511E PT511E...

Страница 248: ...1 Xn 230V 127V 0 PRS210ED A KM811 KM811 PT511E PT511E PA Mody C 1 6 3 7 1 6 3 7 SE X3 Xn MD1 ED M 1 ED A P MD2 241D MA2 241DMA P P C C E P 1 A S E X2 P Matrix Si 21MR 2 Si 21MR 1 INTERCOMS WITH PRIVAT...

Страница 249: ...a 2 1 4 5 3 7 7b P 1473 SE PA SE KM811 KM811 PT511E PT511E 1 6 3 7 1 6 3 7 Mody MD2 241D MD2 MA2 241DMA MA2 Matrix MD1 ED M 1 ED A P MD1 ED M 1 ED A P INTERCOMS CONNECTED TO 2 AUTOMATICALLY SWITCHED E...

Страница 250: ...the same time 1 1 I NTERCOM 4 1 V IDEOINTERCOM PA Door release push button optional SE Electric door lock 12VAC 1A max common of buttons 1 and 2 toseparatethecommonof buttons cut here common of butto...

Страница 251: ...ERCOMSYSTEM Application of 1 videointercom and 3 parallel intercoms Application of 1 videointercom and 2 parallel intercoms 230V 127V 0 1281 X Y H F 10 4 A I A IV X Y H F 10 4 3 1 1P 1M H RL37D X Y H...

Страница 252: ...7 W1 SM50 B C R1 Mody MD2 241D MA2 241DMA Matrix MA43ED PT5111E WB5111E KM8111 WB8111 PT511E KM811 PT511E KM811 PT5111E WB5111E KM8111 WB8111 Conversation privacy Incaseofconversationprivacyfunc tion...

Страница 253: ...10 10a X Y H F 10 4 230V 127V 0 P MD1 ED MD41D Mody MD2 241D MD2 MA2 241DMA MA2 Matrix MA43ED PT5111E WB5111E PT5111E WB5111E KM8111 WB8111 KM8111 WB8111 Mody Matrix MD1 ED M 1 ED A P Si 42MR 1 Contro...

Страница 254: ...y MD2 241D MA2 241DMA Matrix Matrix MA43ED PT5111E WB5111E PT5111E WB5111E KM8111 WB8111 KM8111 WB8111 P P C E P C 1 A S P MD2 MA2 MD1 ED M ED A43 Si 42MR 2 Control switching ON deactivation Toactivat...

Страница 255: ...81E 1181E F F H H 4 4 C C 7b 2 1 7b 2 1 3 7 3 7 A A 8b 9b 10b 8b 9b 10b 5 5 6 6 7a 7a 8a 8a 9a 9a 10a 10a A F 3 4 H C X F H x3 A x3 B x2 A x2 B P P 1 A S MD41D Mody Mody Matrix Matrix MD2 MA2 MD1 ED M...

Страница 256: ...7 A A 8b 9b 10b 8b 9b 10b 5 5 6 6 7a 7a 8a 8a 9a 9a 10a 10a A F 3 4 H C X F H x3 A x3 B x2 A x2 B P P 1 A S MD41D Mody Mody Matrix Matrix MD2 MA2 MD1 ED M ED A43 MD2 241D MD2 241D MD1 ED MD1 ED M ED A...

Страница 257: ...s MD96 Rain shelter for 6 modules 2 frames with 3 modules MD908 Rain shelter for 8 modules 2 frames with 4 modules MD99 Rain shelter for 9 modules 3 frames with 3 modules MD912 Rain shelter for 12 mod...

Страница 258: ...s for 2 users Mody push button panel 241DMA Module with diodes for 4 users Matrix push button panel 1181E Power supply timer 1471 Relay unit 1471E Relay unit 1472 2 contact relay unit 1473 4 contact e...

Страница 259: ...agrams contained in this manual at any time without prior notice The diagrams and information contained in this manual have been carefully verified and are to be considered as reliable However ACI FAR...

Отзывы: