䬂ܹ᭛ᄫ
]
Door phone
Field Name
Explanation
Initial Value
Access control Settings
Switch Mode
Monostable: there is only one action and status-open door mode;
Bistable: there are two actions and statuses-open door and close
door; each action might be triggered and changed to the other
status; after changed, the status would be kept
monostable
Keyboard mode
Only password: there is only accepted password input; dialing
would be forbidden;
Pdialing: there might be password input, dialing(* key for
getting dialing tone, hang up calls; # key for confirming )
Dialing and
password input
Switch-On
Duration
Opened door time for monstable mode. If the time is up, door
switch would be closed automatically
5 seconds
Talk Duration
After time is up, the call will be ended automatically.
120 seconds
Remote Password
Remote opening door password.
*