25
send a radio control every minute. During the
normal operation, some radio signals might be
lost due to external disturbance: in any case,
such disturbance will, provided it does not of-
ten occur in time, not affect the correct equip-
ment operation.
Fastening the socket
The programmable thermostat is supplied
complete with a socket suitable for
fi
tting both
to a wall and to rectangular built-in cases (ei-
ther of the 3-seat or round types).
DRILLING CENTRE DISTANCES
Separate the socket from the programmable
thermostat by levering on the slot found at the
socket bottom by using a suitable tool.
Make sure that the socket is properly secured
and is not deformed. Verify that the program-
mable thermostat connection multi-pole con-
nector is found at the left bottom corner.
To ensure correct operation of the socket, the
latter should be positioned approximately 1.5
m above the
fl
oor level, far from heat sources
(heating radiators, direct sunshine, etc.), doors
and windows.
The distance between the programmable
thermostat and the radio actuators shall not
exceed 30 m (indoors) and 70 m (outdoors).
(N.B. The range data may vary depending on
the ambient conditions). Avoid screening the
devices by using metal components.
60