19
In-
dex
Parameter
Writing
Values
Preset
value
1
Type of con-
nected card
COn
rEL/ rAd / --- None
2
Heating actuator
registration radio
control
rF t
-- -
---
3
Humidity adjust-
ment enable
rH
ON/OFF
OFF
3A
Humidi
fi
cation
actuator registra-
tion radio control
rF rH
-- -
---
4
Temperature
scale
CELS
or FHAr
°C / °F
°C
5
Type of
adjustment
Std or
ProP
Std / ProP
Std
5A
Thermal
differential
DIFF
HI / LO
LO
5A
Adjustment band bAnd
1 °C – 4 °C
(step 0.1°C)
2 °C
5B
Adjustment
period
PEr
5 / 10 / 20
minutes
10
minutes
6
Separate
temperature
probe
con
fi
guration
SEct
--- / FLO / In
/ Out
---
6A
Floor
temperature limit
tFLO
15 °C –
45 °C
27.0 °C
Each con
fi
guration parameter, which features
its own preset settings, is identi
fi
ed on the dis-
play by an index and a writing. To modify the
parameter values, use the
▲
[button 1] and
▼
[button 2] buttons. To move across the param-
eters, use the
►
[button 4] button.
To go back to the initial page of the program-
ming menu, press the ENTER [button 5] but-
ton, which will store the modi
fi
cations into the
memory.
If no button is pressed within 3 minutes, the
programmable thermostat will exit the con
fi
gu-
ration program and the operating mode previ-
ously used will be resumed, without saving.
To eliminate the modi
fi
cations made and
resume the preset con
fi
guration parameter
values, keep the
▲
[button 1] and
▼
[button 2]
buttons depressed simultaneously for approxi-
mately 4 seconds.