19
WARNING
To prevent severe scalding do not remove the radiator cap or try to change
liquid, when the engine is still hot. Wait until it cools.
Coolant level
- Place the motorcycle in riding position.
- Turn the radiator cap (A) counterclockwise and wait a few seconds until
vapors inside are released. Then push and turn it further in the same direc-
tion and remove the cap.
A
NOTE
Check the level when the engine is cold.
- Check the coolant level. The coolant level should be just at a level below
de cap rubber seal.
- If the coolant level is low, add the correct amount of coolant through the
fi
ller opening.
Total quantity
Mix antifreeze and distilled water 1:1 (distilled water 50%, antifreeze 50%).
Capacity: 1,1L.
Coolant Replacement
Coolant should be changed periodically to ensure long engine life.
- Wait for the engine to cool completely.
- Place the motorcycle in riding position.
- Remove the radiator cap.
- Place a container under the coolant drain screw, and drain the coolant
from the radiator and engine by removing the drain screw (B) at the
bottom of the water pump cover (A). Wash o
ff
immediately any coolant
spilled on the chassis, engine, or wheels.
(A)
(B)
200/250/300
125 cc.
(A)
(B)