Wiring Diagram – SER1504, SER2004

Содержание SER 1504

Страница 1: ...tional Building Code and or ASHRAE s Good Engineering Practices Fantech reserves the right to modify at any time and without notice any or all of its products features designs components and specifications to maintain their technological leadership position Please visit our website www fantech net for more detailed technical information United States 10048 Industrial Blvd Lenexa KS 66215 Tel 800 7...

Страница 2: ...h vented combustion equipment i e Gas Furnaces Oil Furnaces Wood Stoves etc Products are designed and manufactured to provide reliable performance but they are not guaranteed to be 100 free of defects Even reliable products will experience occasional failures and this possibility should be recognized by the user If these products are used in a life support ventilation system where failure could re...

Страница 3: ...stalling the ducting to the weatherhood 9 INTERIOR DUCTING INSTALLATION General Tips 10 Installing duct to ERV 10 Supply Exhaust Air Grilles Location 10 ERV INSTALLATION 11 START UP PROCEDURE 12 AIRFLOW BALANCING Airflow balancing 12 Airflow adjustment 13 Measuring the airflow using station grid method 13 LOW VOLTAGE CONTROL SYSTEM 14 WIRING DIAGRAM SER1504 SER2004 15 SER3204D 16 TROUBLESHOOTING 1...

Страница 4: ...Floor area Bedrooms 0 1 2 3 4 5 6 7 7 Ft2 m2 CFM L s CFM L s CFM L s CFM L s CFM L s 1500 139 30 14 45 21 60 28 75 35 90 42 1501 3000 139 1 279 45 21 60 28 75 35 90 42 105 50 3001 4500 279 1 418 60 28 75 35 90 45 105 50 120 57 4501 6000 418 1 557 75 35 90 42 105 50 120 57 135 64 6001 7500 557 1 697 90 42 105 50 120 57 135 64 150 71 7500 697 105 50 120 57 135 64 150 71 165 78 ASHRAE 62 2 2010 Table...

Страница 5: ...ystem Static pressure is a measure of resistance imposed on the blower by length of duct work number of fittings used in duct work duct heater etc FULLY DEDICATED SYSTEM BEST FOR NEW CONSTRUCTION Bathroom Bedrooms Fresh Air Exhaust Air Central Control optional Fresh air to living room Exhaust CG 4 4 Adjustable Grill FEL 4 4 Miter Elbow 460 mm 3m ERV 1 Stale air is drawn from key areas of the home ...

Страница 6: ...s in the house bedrooms living room via forced air system 3 The ERV s airflow must be balanced on site using the procedure found in section AIRFLOW BALANCING ERV Furnace ducting for Partially Dedicated System Stale air coming from different areas of the house ie bathroom kitchen Unit air flow should be balanced while ERV is on High speed and fur nace blower is running Air return 1 m 3 3 min recomm...

Страница 7: ... purposes only 3m 10 minimum separation and 460mm 18 above grade is recommended 5 Due to the differences in pressure between the ERV and the equipment it is being connected to the ERV s airflow should be balanced on site using the procedure found in section AIRFLOW BALANCING NOTE In the case of a sim plified installation Option 1 is recommended Example only duct configuration may differ depending ...

Страница 8: ...nces in pressure between the ERV and the equipment it is being connected to the ERV s airflow must be balanced on site using the procedure found section AIRFLOW BALANCING Installation examples Cont d NOTE In the case of a sim plified installation Option 1 is recommended Stale air coming from different areas of the house ie bathroom kitchen Unit air flow should be balanced while ERV is on High spee...

Страница 9: ...e outer liner which acts as a vapor barrier must be completely sealed to the outer wall and the ERV using tape and or caulking A good bead of high quality caulking preferably acoustical sealant will seal the inner flexible duct to both the ERV duct connection and the weatherhood prior to securing them To minimize airflow restriction the flexible insulated duct that connects the two outside weather...

Страница 10: ...flexible duct to prevent leakage between the ducting and the duct connection In the case of solid ducting slide duct over duct connection screw in place and seal SUPPLY AIR GRILLES LOCATION In homes without a forced air furnace fresh air should be supplied to all habitable rooms including bedrooms and living areas It should be supplied from high wall or ceiling locations Grilles that diffuse the a...

Страница 11: ...outside wall on which the supply and exhaust hoods will be mounted Have a nearby power supply 120 Volts 60Hz power cord is 3 feet long Mount the unit as level as possible in order to allow proper condensate drainage Have access to a water drain for the condensate of the unit during defrost Have a certain amount of heat around the unit attic installation is not recommended Installations close to th...

Страница 12: ... exactly the same it is recommended to have a higher return air flow to ensure that the temperature of the supply air flow coming from outside is as close to room temperature as possible For optimal performance ERV unit should be re balanced after a major renovation or after the installation of extra grilles or registers 2 Install the drain hose making a P trap 1 Install the drain nipple Installin...

Страница 13: ...uld also be made prior to any transition in the duct work so entire airflow is measured Measuring the airflow using station grid method Adjusting airflows A damper is integrated into the Fresh Air to Building collar This damper replaces the installation of a separate damper into the Fresh Air to Building ducting line The damper collar is pre set in the fully opened position If the procedure requir...

Страница 14: ...on system resumes to its previous mode of operation EDF1 1R Press button once for continuous LOW speed Press button twice and the unit will cycle 20 minutes ON 40 minutes OFF and repeat EDF1 Press button a third time and the system will run continuously on HIGH speed EDF1R Press button a third time and the system will run recirculation on HIGH speed AUXILIARY CONTROL These controls can be paired R...

Страница 15: ...15 fantech Wiring Diagram SER1504 SER2004 ...

Страница 16: ...16 fantech Wiring Diagram SER3205D ...

Страница 17: ...nt d ELECTRICAL CONNECTION TO FURNACE FOR A FURNACE CONNECTION TO A COOLING SYSTEM On some older thermostats energizing the R and G terminals at the furnace has the effect of energizing Y at the thermostat and thereby turning on the cooling system If you identify this type of thermostat you must use the Alternate Furnace Interlock Wiring Standard Accessory Control Contact Alternative Accessory Con...

Страница 18: ...illes Inadequate power supply at site Have electrician check supply voltage Ductwork is restricting airflow Check duct installation Improper speed control setting Increase the speed of the ERV i e change unit control from REDUCED to NORMAL speed ERV airflow improperly balanced Have contractor balance ERV airflows Ducting has fallen down or been disconnected from ERV Have contractor reconnect ducti...

Страница 19: ...ntial damages incurred in the use of the ventilation system Fantech is not responsible for providing an authorized service centre near the purchaser or in the general area Fantech reserves the right to supply refurbished parts as replacements Transportation removal and installation fees are the responsibility of the purchaser The purchaser is responsible to adhering to all codes in effect in his a...

Страница 20: ...robe 40286 40326 3 Electrostatic Filters 402041 40327 4 Energy Recovery Cell 401109 422711 5 Door Switch 410867 410867 6 Capacitors 410012 410040 7 PCB UNICTRL 402004 402004 8 Auto Transformer 411963 411963 9 Control Switch 410213 410213 10 PCB Wiring Panel 411719 411719 11 Kit Drain Plug 40315 40315 12 Motor Assembly 405520 40323 Door Kit 405537 405539 ...

Страница 21: ... 411467 3 Temperature Probe 40326 4 Electrostatic Filters Kit 11 5 x 11 40328 5 Energy Recovery Cell 422712 6 Door Switch 410867 7 Capacitors 6uF 411222 8 Electronic Board 402004 9 Auto Transformer 411963 10 Control Switch 410213 11 PCB Wiring Panel 411719 12 Kit Drain Plug 40315 13 Motor Assembly 405520 Door Kit 405540 ...

Страница 22: ...22 fantech Notes ...

Страница 23: ...23 fantech Notes ...

Страница 24: ...fantech Fantech reserves the right to make technical changes For updated documentation please refer to www fantech net Fantech ...