Fantech MUAS 1600 Скачать руководство пользователя страница 2

2

fantech

Note

Warning /

Important 

note

Information

Technical 

information

Practical tip

Warnings

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, 
OBSERVE THE FOLLOWING:

1. Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with national electric codes, local electric 
codes, ordinances and regulations, including fire-rated construction 
codes and standards. 

2. This system is not designed to provide combustion air for fuel- 

burning appliances.

3. Do not connect the system directly to a combustion appliance of any 

type.

4. Before servicing or cleaning any system component, switch power off 

at service panel and lock the service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a prominent 
warning device, such as a tag, to the service panel.

5. When performing installation, servicing or cleaning of the system, it 

is recommended to wear safety glasses and gloves.

6. Locate the outside air inlet hood above any anticipated snow drift 

level and away from any architectural and landscape features to 
ensure that the intake area for the outside air duct is not blocked and 
provides a clear pathway for outside air to enter the system.

7. When cutting or drilling into wall or ceiling, do not damage electrical 

wiring or other hidden utilities.

8. When notching or drilling into framing including floor supports, rim 

joists, and wall studs, comply with code and manufacturer limitations 
on allowable modifications to these structural members.

9. This system can only be used for its intended design. Any internal 

wiring changes, modifications or bypass of any controls, or 
installation practices not according to the details of the instruction 
manual will void the product warranty. Follow all installation, wiring 
and setup instructions indicated in the manufacturer’s manual.

Caution 

1. Do not locate outside air inlet near hazardous materials or 

explosives.

2. System shall not be installed to introduce air from crawlspaces, 

garages, attics, adjacent dwelling units, or other locations within the 
building shell. System shall be installed to introduce air directly from 
outdoors. 

3. Do not install the makeup air system and supply ductwork directly 

above or closer than a distance of two feet to any furnace or its 
supply plenum, boiler, or other heat producing appliance. 

4. Any ductwork used in conjunction with the system must be installed 

in compliance with all local and national codes that are applicable. 

5. Do not operate the system until all system filters have been installed 

per the system design.

6. Please read the specification label on each system component for 

further information and requirements.

7. Each system component, including filters, should be inspected and 

maintained on a regular basis.

8. This system is intended for installation in a dry location protected 

from moisture.

9. This system must be installed in an accessible location which allows 

for system inspection and maintenance. 

10. This system will automatically provide outdoor air into a building. 

Coordinate with the HVAC designer/contractor the effects that the 
supply of outdoor air will have on the building’s comfort and 
mechanical systems. The HVAC designer should take into 
consideration the makeup air system's frequency and duration of 
use as well as the outdoor air flow quantity.

11. Use this system only in the manner intended by the manufacturer. If 

you have questions, contact the manufacturer at the address or 
telephone number provided in this document. 

12. When federal, provincial or state legislation comprises more 

restrictive installation and/or certification requirements, the 
aforementioned requirements prevail over those of this document 
and the installer agrees to conform to these at his own expense.

13. Do not supply outdoor air to a space or duct system where water 

pipes or water coils might be susceptible to freezing due to the 
supply of outdoor air.

Содержание MUAS 1600

Страница 1: ...Technical Customer Support United States Tel 800 747 1762 Canada Tel 800 565 3548 Installation Manual MUAS Series Makeup Air System Controller Item 497868 Rev Date 2017 09 27...

Страница 2: ...cturer s manual Caution 1 Do not locate outside air inlet near hazardous materials or explosives 2 System shall not be installed to introduce air from crawlspaces garages attics adjacent dwelling unit...

Страница 3: ...on for delivery to the interior space The Fantech Makeup air system components and the system s duct work must be insulated to prevent the formation of condensation Fantech recommends that makeup air...

Страница 4: ...s document 1 Wall Intake Hood FML 2 Fast Clamp FC 3 Shut off Damper ADC 4 Filter cassette FGR HV 5 Makeup Air Fan prioAir EC or FKD EC 6 Silencer LD 7 Duct Heater Stelpro optional 8 Controller FMAC Fi...

Страница 5: ...D E H F G J MUAS 750 MUAS 1200 Model A B C D E F H optional G J K MUAS 1600 10 1 2 12 30 1 2 18 7 8 38 1 2 110 3 8 14 124 3 8 12 12 MUAS 2000 10 3 4 14 30 1 2 20 8 38 1 2 114 1 8 24 138 1 8 14 12 A B...

Страница 6: ...MK 1 12 10 kW heater is Stelpro model SDHR12 10K 240VIP CIR017 OTDD OEMK 12 20 kW heater is Stelpro model SDHR12 20K 240VIP CIR017 LOTDD OEMK 1 Default operating mode Setting is W1 Default temperature...

Страница 7: ...o methods 1 Using a pressure differential gauge either digital or analog as used for blower door testing measure the house pressure with respect to the outdoors across a door or window If the house pr...

Страница 8: ...ATER CONNECTIONS 10KW HEATER 41 7 Amp Load 24V WIRE W1 TO 10 24V COMMON WIRE TO 7 20KW HEATER 83 3 Amp Load 24V WIRE W1 TO 10 24V COMMON WIRE TO 7 Makeup Air Fan RED YEL BLU T S Ma Controller Operatio...

Страница 9: ...ACK OF THE MODULE AND MOUNT THE MODULE TO THE ENCLOSURE BACK PANEL USING THE 2 HOLES PROVIDED WALL MOUNTING PLATE NEMA 1 ELECTRICAL ENCLOSURE ELECTRICAL ENCLOSURE BACK PANEL 5 16 18 X 5 8 MOUNTING STU...

Страница 10: ...e CS650 10 aperture V output is approx 5 V DC Keeping the amperage reading close to 10 Amps will increase your systems accuracy Always monitor the neutral wire of the exhaust fan motor This will allow...

Страница 11: ...SOR INSTALLATION AIRFLOW FRONT DRILL O1 2 13mm 40 1016mm RECOMMENDED POSITION TEMPERATURE SENSOR DO NOT INSTALL THE SENSOR IN AN ELBOW OR A TRANSITION X X TEMPERATURE SENSOR INSTALLATION AIRFLOW FRONT...

Страница 12: ...ation for any breach of warranty WARRANTY VALIDATION The user must keep a copy of the bill of sale to verify purchase date These warranties give you specific legal rights and are subject to an applica...

Страница 13: ...13 fantech Notes...

Страница 14: ...14 fantech Notes...

Страница 15: ...15 fantech Notes...

Страница 16: ...Fantech reserves the right to make technical changes For updated documentation please refer to www fantech net Fantech...

Отзывы: