Fancom 743
5. Function keys
30
5.14 Feed clock
A feeding system transports the feed from the storage silos to the animals in the section. Feeding
times can be entered as start and run times using the feed clock. 24 different start and run times
can be set per storage silo.
Start RunT End
At
Start enter the time at which the feed system for this storage silo
should start; at
Run Time how long (hours, minutes and seconds) the
system must remain active. The computer calculates the
End Time (the
time at which the system should stop) using these two settings.
Status
FREE
Status must be FREE to enable feeding.
BLOCKED No feeding will take place if
Status is BLOCKED.
SKIP
If the feeding time, for whatever reason, is to be omitted, set
status to SKIP. As soon as the set run time has elapsed, the
computer will reset the status to FREE.
Copy to all
storage silos?
Set to YES to copy all settings made for this storage silo to the other
storage silos.
>>Feed clock_1
1
Start RunT End
9:00 1:30: 0 10:30
>>
Status FREE
>>
Copy to all
storage silos?
NO
next feed clock (max. 24 times per storage silo)
previous feed clock
Содержание 743