Fancom 743
5. Function keys
33
Level LOW%
Enter the minimum light intensity.
Inc/Dec time
Enter the length of time during which the computer increases the light
level from low to high before the start time, and decreases the level from
high to low after the end time.
Light sched.
Enter the active light schedule.
Status
FREE
Status must be FREE to enable the light to activate.
BLOCKED
The light will not switch on if
Status is BLOCKED.
SKIP
If the lighting period, for whatever reason, is to be
omitted, set status to SKIP. As soon as the set run time
has elapsed, the computer will reset the status to
FREE.
Light level(%)
The current light intensity.
Copy to all
storage silos?
Set to YES to copy all settings made for this storage silo to the other
storage silos.
There are six light schedules, which can be used as pre-settings for the active light clock. These
will be active from the day number set at the light schedule . If the day numbers are on 0, the
correct schedule can be selected manually at
Act. Light clock.
Name
Enter a name for this schedule (max. 8 characters). To change text, see
example 3 in section 4.3.
Day
Enter the day number when this light schedule activates
LOW%
Enter the minimum light intensity.
Inc/Dec
Enter the length of time during which the computer increases the light level
from low to high before the start time, and decreases the level from high to
low after the end time.
On RunT Off
At
On enter the time at which the light should switch on; at Run Time how
long (hours, minutes and seconds) lighting must remain active. The computer
calculates the
Off Time using these two settings.
HIGH%
Enter the maximum light intensity.
>>Light_1 SCHED. A*
Name SCHED. 1
Day LOW% Inc/Dec
.. ... .:..
On RunT Off
..:.. .:..:.. ..:..
HIGH% ..
* SCHEDULES A ... F
Содержание 743
Страница 1: ...GB 743 USER MANUAL VERSION C3...