background image

012915

 

TABLE

 

OF

 

CONTENTS

 

1.

  

DESCRIPTION

 

1.1

 

Occupational

 

Safety

 

and

 

Health

 

Act

 

(OSHA)

 

and

 

American

 

National

 

Standards

 

Institute

 

(ANSI)

 

2.

  

APPLICATION

 

2.1

 

Purpose

 

2.1.1

 

Personal

 

Fall

 

Arrest

 

System

 

Application

  

2.1.2

 

Restraint

 

2.2

 

Application

 

Limits

  

2.3

 

Rescue

  

 

 

3.

  

SYSTEM

 

REQUIREMENTS

 

3.1

 

Capacity

 

3.2

 

Compatibility

 

of

 

Connectors

 

3.3

 

Compatibility

 

of

 

Components

 

3.4

 

Making

 

Connections

 

3.5

 

Personal

 

Fall

 

Arrest

 

System

 

3.6

 

Definitions

 

4.

  

INSTALLATION

 

AND

 

OPERATION

 

4.1

   

Fall

 

Clearance

 

Distance

  

4.2

 

Swing

 

Fall

 

4.3

 

Install

 

the

 

Anchor

   

4.4.

 

Connect

 

a

 

PFAS

 

to

 

the

 

Anchor

 

4.5

 

After

 

a

 

Fall

 

5.

  

SPECIFICATIONS

 

6.

  

MAINTENANCE

 

AND

 

STORAGE

 

6.1

 

Storage

 

6.2

 

Remove

 

from

 

Service

 

7.

  

INSPECTION

 

8.

  

LABELS

 

Appendix

 

A

 ‐ 

Table

 

1,

 

Figures

 

1

 

 

5

 

Appendix

 

B

 

 

1.

   

DESCRIPTION

 

The

 

FallTech®

 

Wire

 

Form

 

Anchor

 

discussed

 

in

 

this

 

manual

 

is

 

designed

 

to

 

provide

 

a

 

temporary

 

fall

 

protection

 

anchorage

 

for

 

those

 

personnel

 

working

 

at

 

height

 

and

 

subject

 

to

 

fall

 

hazards.

   

This

 

manual

 

contains

 

two

 

appendices,

 

Appendix

 

A

 

and

 

Appendix

 

B.

  

Appendix

 

A

 

contains

 

tables

 

and

 

figures

 

specific

 

to

 

the

 

Wire

 

Form

 

Anchor.

  

Appendix

 

B

 

contains

 

tables

 

and

 

figures

 

for

 

fall

 

protection

 

in

 

general.

  

Henceforth,

 

all

 

figure

 

and

 

table

 

references

 

in

 

this

 

manual

 

are

 

to

 

Appendix

 

A

 

unless

 

otherwise

 

noted.

 

NOTE:

 

Appendix

 

B

 

contains

 

references

 

to

 

ANSI

 

Z359.

 

The

 

FallTech

 

Wire

 

Form

 

Anchor

 

is

 

not

 

ANSI

 

compliant,

 

references

 

to

 

ANSI

 

in

 

Appendix

 

B

 

notwithstanding.

  

All

 

PFAS

 

and

 

restraint

 

systems

 

attached

 

to

 

the

 

anchor

 

must

 

be

 

ANSI

 

compliant.

 

For

 

purposes

 

of

 

this

 

manual,

 

the

 

anchor

 

may

 

be

 

referred

 

to

 

as

 

the

 

Wire

 

Form

 

Anchor,

 

the

 

anchor,

 

the

 

product,

 

the

 

equipment,

 

or

 

the

 

unit.

 

The

 

anchor

 

is

 

composed

 

of

 

a

 

stainless

 

steel

 

wire,

 

bent

 

into

 

a

 

shaped

 

hoop

 

with

 

a

 

handle

 

that

 

may

 

be

 

squeezed

 

open

 

by

 

hand

 

and

 

quickly

 

placed

 

around

 

a

 

pipe

 

or

 

other

 

approved

 

structural

 

element

 

to

 

form

 

a

 

PFAS

 

anchorage.

  

See

 

Figure

 

1

 

for

 

a

 

product

 

illustration

 

and

 

Table

 

1

 

for

 

product

 

sizes,

 

material

 

and

 

performance

 

specifications.

 

The

 

anchor

 

is

 

designed

 

to

 

be

 

temporary

 

and

 

reusable

 

on

 

a

 

horizontal

 

member,

 

used

 

and

 

moved

 

at

 

will,

 

provided

 

it

 

has

 

not

 

been

 

subjected

 

to

 

fall

 

arrest

 

forces

 

and

 

passes

 

inspection

 

as

 

described

 

in

 

Section

 

7

 

of

 

this

 

manual.

   

1.1

 

Occupational

 

Safety

 

and

 

Health

 

Act

 

(OSHA)

 

and

 

American

 

National

 

Standards

 

Institute

 

(ANSI):

 

The

 

anchor

 

discussed

 

in

 

this

 

manual

 

meets

 

Occupational

 

Safety

 

and

 

Health

 

Act

 

(OSHA)

 

regulations

 

1926.502.

 

The

 

anchor

 

is

 

not

 

ANSI

 

compliant.

 

All

 

PFAS

 

and

 

restraint

 

systems

 

attached

 

to

 

the

 

anchor

 

must

 

be

 

ANSI

 

compliant.

 

2.

 

APPLICATION

 

2.1

 

Purpose:

 

The

 

anchor

 

discussed

 

in

 

this

 

manual

 

is

 

designed

 

to

 

be

 

used

 

as

 

single

 

person

 

anchor

 

point

 

for

 

a

 

PFAS

 

to

 

reduce

 

forces

 

and

 

protect

 

the

 

user

 

in

 

a

 

fall

 

event,

 

and

 

as

 

a

 

fall

 

hazard

 

restraint

 

anchor

 

for

 

inspection

 

work,

 

general

 

construction,

 

maintenance

 

work,

 

oil

 

production,

 

etc.

  

DO

 

NOT

 

use

 

the

 

anchor

 

to

 

lift

 

tools

 

or

 

materials.

 

2.1.1

 

Personal

 

Fall

 

Arrest

 

System

 

Application:

 

 

A

 

PFAS

 

is

 

typically

 

composed

 

of

 

an

 

anchorage

 

and

 

an

 

energy

 

absorbing

 

connecting

 

device,

 

i.e.,

 

a

 

SAL,

 

an

 

SRD,

 

or

 

a

 

Fall

 

Arrester

 

Connecting

 

Subsystem

 

(FACSS),

 

attached

 

to

 

the

 

dorsal

 

D

ring

 

of

 

properly

 

fitted

 

and

 

adjusted

 

FBH.

 

See

 

Figure

 

2.

 

Maximum

 

permissible

 

free

 

fall

 

in

 

a

 

typical

 

PFAS

 

is

 

6'.

  

PFAS

 

used

 

in

 

conjunction

 

with

 

this

 

equipment

 

must

 

meet

 

ANSI

 

Z359

 

requirements

 

and

 

applicable

 

OSHA

 

1926.502

 

regulations.

 

The

 

anchor

 

discussed

 

in

 

this

 

manual

 

is

 

intended

 

for

 

overhead

 

use.

 

Do

 

not

 

use

 

the

 

anchor

 

for

 

any

 

application

 

where

 

the

 

anchor

 

is

 

installed

 

below

 

the

 

FBH

 

dorsal

 

D

ring.

 

An

 

anchorage

 

selected

 

for

 

PFAS

 

must

 

have

 

strength

 

able

 

to

 

sustain

 

a

 

static

 

load

 

applied

 

in

 

the

 

direction

 

permitted

 

by

 

the

 

PFAS

 

of

 

at

 

least:

 

a)

 

Two

 

times

 

the

 

maximum

 

arrest

 

force

 

permitted

 

when

 

certification

 

exists,

 

or

 

b)

 

5,000

 

lbs.,

 

(22.2

 

kN)

 

in

 

the

 

absence

 

of

 

certification

   

2.1.2

 

Restraint:

 

The

 

anchor

 

may

 

be

 

used,

 

in

 

conjunction

 

with

 

the

 

proper

 

equipment,

 

as

 

an

 

anchor

 

for

 

restraint

 

applications,

 

to

 

prevent

 

the

 

user

 

from

 

reaching

 

a

 

fall

 

hazard

 

area.

 

Ensure

 

the

 

anchor

 

will

 

not

 

slide

 

along

 

the

 

anchor

 

structure

 

nor

 

slip

 

off

 

the

 

end

 

of

 

any

 

structure

 

it

 

may

 

be

 

attached

 

to.

 

See

 

Figure

 

2.

 

2.2

 

Application

 

Limits:

  

The

 

Wire

 

Form

 

Anchor

 

is

 

designed

 

for

 

use

 

on

 

pipes

 

and

 

other

 

suitable

 

structures.

  

The

 

anchor

 

may

 

be

 

attached

 

to

 

horizontal

 

members,

 

provided

 

the

 

anchor

 

is

 

correctly

 

oriented.

 

See

 

Figure

 

2.

 

Take

 

action

 

to

 

avoid

 

sharp

 

edges,

 

abrasive

 

surfaces,

 

and

 

thermal,

 

and

 

chemical

 

hazards.

 

Take

 

action

 

to

 

avoid

 

electrical

 

hazards,

 

including

 

exposure

 

to

 

welding

 

operations

 

electric

 

arcs.

 

The

 

anchor

 

is

 

designed

 

for

 

overhead

 

application

 

only.

 

The

 

anchor

 

is

 

not

 

designed

 

for

 

work

 

positioning

 

or

 

personnel

 

riding.

 

The

 

anchor

 

is

 

designed

 

for

 

a

 

range

 

of

 

pipe

 

and

 

other

 

suitable

 

structures.

 

See

 

Table

 

1

 

for

 

minimum/maximum

 

structure

 

diameter

 

range

 

of

 

fit

 

dimensions

 

for

 

each

 

anchor

 

model

 

number.

 

DO

 

NOT

 

attach

 

the

 

anchor

 

to

 

edged

 

structures

 

such

 

as

 

Y

 

or

 

S

 

beams,

 

angle

 

iron

 

or

 

square

 

tube.

 

DO

 

NOT

 

use

 

the

 

anchor

 

to

 

lift

 

tools,

 

materials,

 

or

 

personnel.

 

Only

 

one

 

PFAS

 

may

 

be

 

attached

 

to

 

an

 

anchorage

 

at

 

one

 

time.

 

Only

 

one

 

person

 

may

 

connect

 

to

 

the

 

anchor

 

at

 

a

 

time.

   

2.3

 

Rescue:

 

Rescue

 

operations

 

require

 

specialized

 

equipment

 

that

 

is

 

beyond

 

the

 

scope

 

of

 

this

 

manual.

 

See

 

ANSI

 

Z359.4

2007.

  

3.

  

SYSTEM

 

REQUIREMENTS

 

3.1

 

Capacity:

 

The

 

anchor

 

is

 

designed

 

for

 

a

 

total

 

user

 

weight,

 

including

 

clothing,

 

tools,

 

Содержание 7403

Страница 1: ...er use care and maintenance of this product Retain these instructions and keep them available for the user s reference at all times Alterations or misuse of this product or failure to follow instructions may result in serious injury or death A Fall Protection Plan must be on file and available for review by all users It is the responsibility of the user and the purchaser of this equipment to assur...

Страница 2: ...ssed in this manual is designed to be used as single person anchor point for a PFAS to reduce forces and protect the user in a fall event and as a fall hazard restraint anchor for inspection work general construction maintenance work oil production etc DO NOT use the anchor to lift tools or materials 2 1 1 Personal Fall Arrest System Application A PFAS is typically composed of an anchorage and an ...

Страница 3: ...d be encountered during a fall or that meet the criteria for a certified anchorage prescribed in this standard Competent Person One who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary hazardous or dangerous to employees and who has authorization to take prompt corrective measures to eliminate them Qualified Person A person w...

Страница 4: ...ils NOTE The anchor discussed in this manual is for overhead use attached to a horizontal member only in personal fall arrest applications Do not place the anchor below the user s FBH dorsal D ring The anchor may be used as restraint anchor to prevent the user from reaching a fall hazard DO NOT work above the anchorage DO NOT use the anchor for fall arrest while it is attached to a vertical member...

Страница 5: ...012915 ...

Страница 6: ...del fabricante sobre el uso adecuado el cuidado y el mantenimiento de este producto Conserve estas instrucciones y póngalas a disposición del usuario para que las utilice como referencia en todo momento Las alteraciones o el uso incorrecto de este producto o el incumplimiento de las instrucciones pueden generar lesiones graves o la muerte Se debe contar con un plan de protección contra caídas el c...

Страница 7: ... anclaje con cumple con ANSI Todos los PFAS y sistemas de detención de caídas conectados al anclaje deben cumplir con ANSI 2 APLICACIÓN 2 1 Objetivo El anclaje analizado en este manual está diseñado para utilizarse como un punto de anclaje para una sola persona para que un PFAS reduzca las fuerzas y proteja al usuario en caso de caídas y como un anclaje de restricción contra peligro de caídas para...

Страница 8: ...ere la OSHA el PFAS debe poder detener la caída del usuario con una fuerza de detención máxima de 1800 lb y esta aplicación limita la caída libre a 1 83 m o menos Si se debe exceder la distancia máxima de caída libre el empleador debe documentar sobre la base de datos obtenidos a partir de pruebas que no se excederá esta fuerza de detención máxima y que el sistema de detención de caídas funcionará...

Страница 9: ...os en la Figura 4 Asegúrese de que los ganchos se acoplen en los bucles No conecte el anclaje debajo del nivel del anillo en D dorsal del FBH Consulte la Figura 5 para conocer las instalaciones incorrectas que deben evitarse NOTA Se puede exigir protección contra caídas durante la instalación de todas las unidades de anclaje analizados en este manual 4 4 Conexión de un PFAS al anclaje Inspeccione ...

Страница 10: ...012915 8 0 ETIQUETAS ...

Страница 11: ...mensiones de montaje Minimum Tensile Strength Fuerza de tracción mínima User Capacity Capacidad de usuario 5 000 lbs 5 000 lbs 2267 kg 7402 Stainless Steel 7402 Acero inoxidable 7403 Stainless Steel 7403 Acero inoxidable 7407 Stainless Steel 7407 Acero inoxidable 1 4 diameter 13 L x 5 W 1 4 diámetro 13 L x 5 A 2 Minimum 3 Maximum 2 mínimo 3 máximo 1 4 diameter 15 L x 7 W 1 4 diámetro 15 L x 7 A 2 ...

Страница 12: ...Side Loops Bucles laterales Hook ends Extremos del gancho Retaining Ring Anillo de retención Anchor Handle Manija del anclaje PFAS Connecting Eye Argolla de conexión del PFAS Figure 1 About Wire Form Anchor Figura 1 Acerca del anclaje de forma de alambre TSWF1 1 FSWF1 1 APPENDIX A 021615 ...

Страница 13: ...o usando un SRD Overhead Anchorage Only for Fall Arrest Using a FACSS Detención de caídas del anclaje aéreo usando un FACSS Fall Restraint Attached to Horizontal Member Restricción contra caídas conectada a elemento horizontal Figure 2 Fall Protection Applications Using Wire Form Anchor Figura 2 Aplicaciones de la protección contra caídas usando el anclaje de forma de alambre DSWF2 2 TSWF2 2 APPEN...

Страница 14: ...le Load Direction Only on Major Axis of Anchor Dirección de carga permitida solo en eje principal del anclaje Figure 3 Load Direction of Wire Form Anchor Figura 3 Dirección de la carga del anclaje de forma de alambre TSWF1 1 FSWF3 2 ...

Страница 15: ...er Anchorage Coloque las horquillas abiertas sobre el anclaje Rotate and Release tension to close clamping jaws Rote y libere tensión para cerrar las horquillas de fijación Attach Deceleration Connector to Eye Acople el conector de desaceleración a la argolla Always Maintain Min Clearance on Each Side Mantenga siempre una distancia despejada mín de 6 35 mm de cada lado TSWF4 2 APPENDIX A 021615 DS...

Страница 16: ...n una estructura angular Do Not Use on Sloped Structure No lo utilice en una estructura inclinada Do Not Use if End Hooks and Side Eyes are Not Engaged No lo utilice si los ganchos del extremo y las argollas laterales están mal alineados Do Not Attach Anchor Below Dorsal D Ring No conecte el anclaje debajo del anillo en D dorsal TSWF5 2 APPENDIX A 021615 DSWF5 2 ...

Страница 17: ... de vida con amortiguación de impactosLongitud de trabajo original antes de ocurrir un evento de caída antes de la activación del amortiguador de impactos Distancia de elongación desaceleración Cantidad máxima permitida de elongación que se puede emplear del amortiguador de energía al activarse durante un evento de caída Cambio del anillo en D dorsal y tramo del arnés Cantidad combinada de la elon...

Страница 18: ... D 2 pies 0 6 m Distancia de activación desaceleración Distancia máxima permitida del cable o red que puede emplearse desde el SRD una vez que la desaceleración del usuario ha comenzado y después de que ocurra un evento de caída Cambio del anillo en D dorsal y tramo del arnés Cantidad combinada de la elongación de la red del arnés y el cambio del anillo en D dorsal durante un evento de caída compl...

Страница 19: ...ramiento longitud de la VLL desde el conector de anclaje hasta la posición de agarre de la cuerda en VLL multiplicado por 10 Longitud de la cuerda con amortiguación Longitud de trabajo original antes de ocurrir un evento de caída antes de la activación del amortiguador de energía Distancia de elongación desaceleración Cantidad máxima permitida de elongación que se puede emplear del amortiguador de...

Страница 20: ...Full Body Harness FBH Back up Fall Arrest PFAS Full Body Harness FBH Arnés de cuerpo completo FHB Detención de caídas de respaldo PFAS Arnés de cuerpo completo FHB Walking Working Surface Fall Hazard Area Back up Fall Arrest PFAS Superficie para caminar trabajar TUFPA1 1 Fig 9 Restricción A B C D E Anclaje de restricción Cordón de restricción Arnés de cuerpo completo FHB Superficie para caminar tr...

Страница 21: ...ng Assembly Ensamblaje de posicionamiento con torre Arrest Distance Distancia de detención Shock Absorbing Lanyard Cuerda de salvamento con amortiguación Maximum Arrest Force Fuerza de detención máxima Occupational Safety and Health Administration Administración de Seguridad y Salud Ocupacional Fall Arrestor Connecting Subsystem Subsistema de conexión de detenedor de caídas Self retracting Device ...

Страница 22: ...FallTech 1306 South Alameda Street Compton CA 90221 USA 1 800 719 4619 1 323 752 0066 www FallTech com ...

Отзывы: