SECTION 1 - INSTALLATION

1.2 SITING
The unit must be installed on a firm level,

non-combustible floor in a well lit position.
All models should have a 150mm minimum clearance

all round from any combustible wall and 150mm from

any non-combustible side wall to allow removal of the

side panels. There should be a minimum vertical

clearance of 1220mm above the top edge of range

and boiling table flues.
Important
If the appliance is to be installed in suite formation

with other matching appliances the instructions for all

units must be consulted to determine the necessary

clearance to any combustible rear wall or overlying

surface. Some units require greater clearances than

others. The largest figure quoted in the individual

instructions will therefore determine the clearance for

the complete suite of adjoining appliances.

1.3 VENTILATION
Adequate ventilation, whether natural or mechanical,

must be provided to supply sufficient fresh air for

combustion and for removal of combustion products,

which may be harmful tohealth.
Recommendations for ventilation for catering

appliances are given in BS 5440:2.
Furthermore, to ensure sufficient room ventilation

guidance on the volume of ventilation air required for

different types of catering equipment is provided in

the following table.
For multiple installations, requirements for individual

units should be added together.

Installation should be made in accordance with local

and/or national regulations applying at the time.

A competent installer must be employed.
A direct connection MUST NOT be made to an

extract fan system or to the open air. Flues are best

discharged under a canopy connecting with a

ventilating system.

1.4 GAS SUPPLY
The incoming service must be of sufficient size to

supply full rate without excessive pressure drop.

A gas meter is connected to the service pipe by the

Gas Supplier. An existing meter should be checked,

preferably by the Gas Supplier toensure it is of

adequate capacity tosupply the unit and o

ther

associated equipment.
Installation pipework should be fitted in accordance

with IGE/UP/2. The size of the pipework from the

meter system tothe appliance must be not less than

that of the inlet connection. R

3

/

4

(

3

/

4

" BSP female)

with regulator for Natural Gas and R

1

/

2

(

1

/

2

" BSP

female) without regulator for Propane Models.
Important
Check for gas soundness.
An isolating cock must be located close to the

appliance and accessible tothe user toallo

w

shutdown during an emergency or servicing.

The installation must be purged and tested for gas

soundness, details are given in IGE/UP/1.

The adjustable governor supplied must be fitted to

natural gas appliances in an accessible and spillage

free position and downstream of the isolating cock.

1.5 ELECTRICAL SUPPLY
Not applicable to this appliance.

1.6 WATER SUPPLY
Not applicable to this appliance.

EQUIPMENT

Ventilation Rate Required

m

3

/ min

ft

3

/min

Range, Unit Type

17

600

Pastry Oven

17

600

Fryer

26

900

Grill

17

600

Steak Grill

26

900

Boiling Pan

17

600

Steamer

17

600

Sterilizing Sink

14

500

Bains Marie

11

400

Tea/ Coffee Machine

8.5 - 14

300 - 500

UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER

ARE NOT TO BE ADJUSTED BY THE INSTALLER

MODEL

WIDTH

mm

DEPTH

mm

HEIGHT

mm

WEIGHT

kg

WEIGHT

lbs

G1006X

OPEN TOP

900

940

890

240

530

G1006X

SOLID TOP

900

940

890

245

540

G1016/1

SINGLE TIER

900

940

890 176.5 389

G1006X TWIN

BULLSEYE

900

940

890

253

558

G1016/2

DOUBLE TIER

900

940

1740

353

778

G1026X O/T

BOILING TABLE

900

940

890

141

311

G1060X

BOILING TABLE

900

940

890

159

350

G1026X S/T

BOILING TABLE

900

940

890

159

350

G1066X

OPEN TOP

900

940

890

255

560

G1029X

SPREADER

450

940

890

75

165

1.1 MODEL NUMBERS, NETT WEIGHTS

and DIMENSIONS

Содержание G1006X

Страница 1: ...structions should be left with the Engineer in Charge for reference during servicing Further to this the Users Instructions should be handed over to the User having had a demonstration of the operatio...

Страница 2: ...ll rate without excessive pressure drop A gas meter is connected to the service pipe by the Gas Supplier An existing meter should be checked preferably by the Gas Supplier to ensure it is of adequate...

Страница 3: ...1 9 INJECTOR SIZES Natural and Propane Gas 1 10 GAS PRESSURE A test point is located upon the manifold behind the control panel Solid top single and double tier oven model access is gained by removing...

Страница 4: ...er resting on the front and rear sloping angles The two plates should touch at the centre Note The top surface of each plate has one lifting lug directed toward the oven centre Replace all parts in re...

Страница 5: ...One service void end p a n e l n o r m a l l y contains two holes which accommodate the header pipes See Figure 5 Gas Governors An adjustable gas governor is supplied with each natural gas model Serv...

Страница 6: ...s responsible understands the instructions for lighting turning off and correct use and care of the appliance It is important to ensure that the location of the gas isolating cock is made known to the...

Страница 7: ...ports Remove the cast iron heat shields Disconnect the thermocouple electrode and pilot gas supply from the pilot burner Undo the fixings which secure the front end of the burner to the base and slide...

Страница 8: ...he roof baffle e Gently pull the phial and capillary tube through the oven side hole and withdraw the thermostat f Remove the right angled bracket from the existing thermostat and replace it on the ne...

Страница 9: ...ttention however the air breather hole should be cleaned regularly during routine maintenance Access to this area is achieved by removing the top cover The hole is located 15mm off centre and may be c...