7
Table 4 – Technical data (injector table)
Cat.:
II2H3+
TYPE
OF
CONSTRUCTION
“A”
Model
80lt
Rated
power
(kW)
22
Minimum
power
(kW)
“ON/OFF”
Gas
consumption
G20
(Hi
=
9,45
kWh/m3)
in
m3/h
G30
(Hi
=
12,68
kWh/kg)
in
kg/h
2,3
1,73
Injector
Ø
In
1/100
mm
Pilot
G20
20mbar:
Rated
power
Minimum
power
40
4
x
270
“ON/OFF”
25
4
x
120
“ON/OFF”
Pilot
G30
28
‐
30/37
mbar:
Rated
power
Mini.
power
Primary
distance
“H”
G20
G30
20
30
Table 7a
Nominal main pressure for the
Gas family 2 – Natural
20 mbar
different types of gas
Gas family 3 – Propane
28-30/37 mbar
Table 7b
Operation permissible
Gas family 2 – Natural
from 17 mbar
if pressure is in the range:
Gas family 3 – Propane
from 20/25 to 35/45 mbar
Table 7c
Operation non permissible
Gas family 2 – Natural
from 17 to 25 mbar
if pressure is lower than:
Gas family 3 – Propane
from 20/25 mbar
Table 7d
Operation non permissible
Gas family 2 – Natural
25 mbar
if pressure is higher than:
Gas family 3 – Propane
from 35/45 mbar