Falcon F900 G9881 Скачать руководство пользователя страница 12

12

 

 

That the water and gas connections are leak-free; 

That the electrical connection has been performed according to standards. 

Now the burner can be lit by following instructions for use and these points: 

Progressive ignition of the burner; 

even flame; 

flame security: check these points at both minimum and maximum output. 

Check flue gas exhaust is not clogged and that they are expelled without any hindrance. 

The test report must be completed in full and submitted to the customer who should then 
sign in acceptance. With effect from this moment, the appliance is covered by the 
manufacturer’s warranty. 

2.5. CONVERSION TO OTHER TYPES OF GAS 

To adapt appliance to another gas type, for instance from G20 to G30, it is necessary to 
control if main burner injectors and by-pass screws have been installed properly; in addition, 
it is also necessary to replace the oven pilot burner injector (see Table 5 “Technical Data”).  

All injectors needed for different types of gas are supplied with unit. 

2.5.1. REPLACEMENT OF INJECTORS FOR MAIN BURNERS 

To access injectors, remove water inlet tap knob, control panel and pan-tilting hand wheel. 

2.5.2. REPLACEMENT OF INJECTORS FOR PILOT BURNER 

Undo screw (E) and replace injector (D) with appropriate injector (see Table 3). 

With a size 12 key, undo injector and replace it with injector to suit gas supply (see Table 3).  

Control the correct distance “H” for primary air (refer to Section 4.6). 

ATTENTION!

 After each conversion, the unit must be tested to ensure that there are no 

leakages and that it operates correctly. 

2.6. MAINTENANCE OF THE APPLIANCE 

Warning!: All maintenance operations shall only be performed by a technically qualified 
service centre! 

To ensure correct and safe operation, the appliance must be inspected and serviced at least 
once a year only. Maintenance includes components, pipes, feeding pipes etc. 

It is advisable to replace worn components during maintenance operations to avoid the need 
for other maintenance calls and unexpected failures. 

It is also advisable to apply for a maintenance contract with the customer. 

 

 

 

Содержание F900 G9881

Страница 1: ...F900 SERIES User installation and servicing instructions BRATT PAN G9881 Read these instructions before use T100914 REV 1 DATE PURCHASED MODEL NUMBER SERIAL NUMBER DEALER SERVICE PROVIDER...

Страница 2: ...iance and any replacement parts in a safe manner via a licensed waste handler Appliances are designed to be dismantled easily and recycling of all material is encouraged whenever practicable Dear Cust...

Страница 3: ...must be used by qualified persons The installer must instruct the responsible person s of the correct operation and maintenance of the appliance Only competent persons are allowed to service or conver...

Страница 4: ...4 Operation control 12 2 4 Commissioning and testing 12 2 5 Conversion to other gas types 12 13 2 5 1 Replacement of injectors for main burners 13 2 5 2 Replacement of injectors for pilot burner 13 2...

Страница 5: ...he appliance should be used only for the purpose for which it has been specifically designed other uses are improper and hence dangerous During operation surfaces can become hot Unplug appliance in th...

Страница 6: ...R 1 2 TECHNICAL DATA G a s p a r t Model Outer dimensions cm Qn kW Gas connection G20 Hi 9 45 kWh m m h G30 Hi 12 68 kWh kg kg h 80 litre 80X90X90 22 R 2 3 1 73 Cooking Pan Characteristics Model Dimen...

Страница 7: ...ry distance H G20 G30 20 30 Table 7a Nominal main pressure for the Gas family 2 Natural 20 mbar different types of gas Gas family 3 Propane 28 30 37 mbar Table 7b Operation permissible Gas family 2 Na...

Страница 8: ...ired systems utilizing natural or propane gas Standards relating to gas fired cooking appliances and equipment for large scale catering Safety requirements Standards relating to gas systems for applia...

Страница 9: ...is appliance Warning Before connecting any part of the unit to main supplies make sure that the latter is equivalent the requirements stated in the technical data plate if the appliance has been desig...

Страница 10: ...liminary regulation The possibility of operation depends on the supply pressure available Admitted if inlet pressure is within the range 20 35 and 25 45 mbar Non admitted if the pressure is lower than...

Страница 11: ...tion is indicated in Table 4 2 3 3 CONTROL OF PILOT BURNER Start the pilot burner according to instructions If the pilot is adjusted correctly the ignition flame will contact the thermocouple evenly a...

Страница 12: ...needed for different types of gas are supplied with unit 2 5 1 REPLACEMENT OF INJECTORS FOR MAIN BURNERS To access injectors remove water inlet tap knob control panel and pan tilting hand wheel 2 5 2...

Страница 13: ...main burner does not light Loss of pressure in the gas supply The injector is clogged or the gas cock is damaged The gas outlet holes are clogged The heating pan temperature cannot be adjusted The bu...

Страница 14: ...ign a service agreement In case of failures concerning the appliance all outputs gas and water must be cut off instantly In case of recurrent failures contact a service technician 3 2 INSTRUCTIONS FOR...

Страница 15: ...ast annually For this purpose it is advisable to arrange a service contract with Serviceline Keep thermocouples clean and handle such parts carefully Inspect burner holes periodically these must alway...

Страница 16: ...sh Be absolutely certain to shut off all utilities gas and water Air the room appropriately 3 5 SPECIAL PROCEDURES IN CASE OF FAILURES If the appliance should not work properly during use turn it off...

Страница 17: ...17 SECTION 4 FIGURES and DETAILS 4 1 UNIT DIMENSIONS AND CONNECTION POSITIONS A Water connection d 12 G Gas connection R in conformity with ISO 7 1...

Страница 18: ...18 4 2 MEASURING THE INLET PRESSURE A Screw B Pressure intake C Gas tube A C B...

Страница 19: ...t screw G Maximum output adjustment screw C Gas outlet for pilot H Gas outlet D Pressure plug at inlet I Gas inlet E Pressure plug at outlet L Control knob IMPORTANT The visible adjustment screws on t...

Страница 20: ...20 4 4 PILOT BURNER A Thermocouple D Injector B Pilot burner E Tightness screw C Ignition plug 4 5 MAIN BURNER A Burner B Injector C Injector pipe B C A...

Страница 21: ...AIR REGULATION 4 7 KNOB FOR WATER INLET CLOSED OPEN 4 8 CONTROLS A Control knob E Maximum position C OFF position F Pilot burner D Minimum position H A 7 6 5 4 3 2 1 C 1 2 3 4 6 5 7 F 3 2 5 1 4 7 6 D...

Отзывы: