Falcon F900 G9881 Скачать руководство пользователя страница 4

4

 

 

CONTENTS

 

Section

 

1:

 

General

 

reminders

 

and

 

notes

 

1.1.

 

General

 

reminders

 

6

1.2.

 

Technical

 

data

 

7

 ‐ 

8

1.3.

 

Construction

 

8

1.4.

 

Installation

 

conformity

 

8

 ‐ 

9

1.5.

 

Special

 

requirements

 

for

 

the

 

installation

 

site

 

9

Section

 

2:

 

Positioning,

 

installation

 

and

 

maintenance

 

2.1.

 

Positioning

 

9

2.2.

 

Installation

 

10

2.2.1.

 

Connection

 

to

 

water

 

supply

 

10

2.2.2.

 

Gas

 

connection

 

procedures

 

10

2.3.

 

Checking

 

gas

 

system

 

operation

 

10

 ‐ 

11

2.3.1.

 

Control

 

of

 

gas

 

inlet

 

pressure

 

11

2.3.2.

 

Control

 

of

 

primary

 

air

 

flow

 

 

11

2.3.3.

 

Control

 

of

 

pilot

 

burner

 

12

2.3.4

 

Operation

 

control

 

12

2.4.

 

Commissioning

 

and

 

testing

 

12

2.5.

 

Conversion

 

to

 

other

 

gas

 

types

 

12

 ‐ 

13

2.5.1.

 

Replacement

 

of

 

injectors

 

for

 

main

 

burners

 

13

2.5.2.

 

Replacement

 

of

 

injectors

 

for

 

pilot

 

burner

 

13

2.6.

 

Maintenance

 

of

 

appliance

 

13

2.6.1.

 

Troubleshooting

 

13

 ‐ 

14

Section

 

3:

 

Use

 

and

 

cleaning

 

3.1.

 

Warnings

 

and

 

hints

 

for

 

user

 

14

3.2.

 

Instructions

 

for

 

use

 

15

3.2.1.

 

Basic

 

operation

 

15

3.3.

 

Cleaning

 

and

 

care

 

of

 

the

 

appliance

 

15

 ‐ 

16

3.3.1.

 

Daily

 

cleaning

 

16

3.4.

 

Special

 

procedures

 

in

 

case

 

of

 

long

 

inactivity

 

16

3.5.

 

Special

 

procedures

 

in

 

case

 

of

 

failures

 

16

Section

 

4:

 

Figures

 

and

 

details

 

4.1.

 

Unit

 

dimensions

 

and

 

connection

 

positions

 

17

4.2.

 

Measuring

 

inlet

 

pressure

 

18

4.3.

 

Gas

 

cock

 

detail

 

19

4.4.

 

Pilot

 

burner

 

20

4.5.

 

Main

 

burner

 

20

Содержание F900 G9881

Страница 1: ...F900 SERIES User installation and servicing instructions BRATT PAN G9881 Read these instructions before use T100914 REV 1 DATE PURCHASED MODEL NUMBER SERIAL NUMBER DEALER SERVICE PROVIDER...

Страница 2: ...iance and any replacement parts in a safe manner via a licensed waste handler Appliances are designed to be dismantled easily and recycling of all material is encouraged whenever practicable Dear Cust...

Страница 3: ...must be used by qualified persons The installer must instruct the responsible person s of the correct operation and maintenance of the appliance Only competent persons are allowed to service or conver...

Страница 4: ...4 Operation control 12 2 4 Commissioning and testing 12 2 5 Conversion to other gas types 12 13 2 5 1 Replacement of injectors for main burners 13 2 5 2 Replacement of injectors for pilot burner 13 2...

Страница 5: ...he appliance should be used only for the purpose for which it has been specifically designed other uses are improper and hence dangerous During operation surfaces can become hot Unplug appliance in th...

Страница 6: ...R 1 2 TECHNICAL DATA G a s p a r t Model Outer dimensions cm Qn kW Gas connection G20 Hi 9 45 kWh m m h G30 Hi 12 68 kWh kg kg h 80 litre 80X90X90 22 R 2 3 1 73 Cooking Pan Characteristics Model Dimen...

Страница 7: ...ry distance H G20 G30 20 30 Table 7a Nominal main pressure for the Gas family 2 Natural 20 mbar different types of gas Gas family 3 Propane 28 30 37 mbar Table 7b Operation permissible Gas family 2 Na...

Страница 8: ...ired systems utilizing natural or propane gas Standards relating to gas fired cooking appliances and equipment for large scale catering Safety requirements Standards relating to gas systems for applia...

Страница 9: ...is appliance Warning Before connecting any part of the unit to main supplies make sure that the latter is equivalent the requirements stated in the technical data plate if the appliance has been desig...

Страница 10: ...liminary regulation The possibility of operation depends on the supply pressure available Admitted if inlet pressure is within the range 20 35 and 25 45 mbar Non admitted if the pressure is lower than...

Страница 11: ...tion is indicated in Table 4 2 3 3 CONTROL OF PILOT BURNER Start the pilot burner according to instructions If the pilot is adjusted correctly the ignition flame will contact the thermocouple evenly a...

Страница 12: ...needed for different types of gas are supplied with unit 2 5 1 REPLACEMENT OF INJECTORS FOR MAIN BURNERS To access injectors remove water inlet tap knob control panel and pan tilting hand wheel 2 5 2...

Страница 13: ...main burner does not light Loss of pressure in the gas supply The injector is clogged or the gas cock is damaged The gas outlet holes are clogged The heating pan temperature cannot be adjusted The bu...

Страница 14: ...ign a service agreement In case of failures concerning the appliance all outputs gas and water must be cut off instantly In case of recurrent failures contact a service technician 3 2 INSTRUCTIONS FOR...

Страница 15: ...ast annually For this purpose it is advisable to arrange a service contract with Serviceline Keep thermocouples clean and handle such parts carefully Inspect burner holes periodically these must alway...

Страница 16: ...sh Be absolutely certain to shut off all utilities gas and water Air the room appropriately 3 5 SPECIAL PROCEDURES IN CASE OF FAILURES If the appliance should not work properly during use turn it off...

Страница 17: ...17 SECTION 4 FIGURES and DETAILS 4 1 UNIT DIMENSIONS AND CONNECTION POSITIONS A Water connection d 12 G Gas connection R in conformity with ISO 7 1...

Страница 18: ...18 4 2 MEASURING THE INLET PRESSURE A Screw B Pressure intake C Gas tube A C B...

Страница 19: ...t screw G Maximum output adjustment screw C Gas outlet for pilot H Gas outlet D Pressure plug at inlet I Gas inlet E Pressure plug at outlet L Control knob IMPORTANT The visible adjustment screws on t...

Страница 20: ...20 4 4 PILOT BURNER A Thermocouple D Injector B Pilot burner E Tightness screw C Ignition plug 4 5 MAIN BURNER A Burner B Injector C Injector pipe B C A...

Страница 21: ...AIR REGULATION 4 7 KNOB FOR WATER INLET CLOSED OPEN 4 8 CONTROLS A Control knob E Maximum position C OFF position F Pilot burner D Minimum position H A 7 6 5 4 3 2 1 C 1 2 3 4 6 5 7 F 3 2 5 1 4 7 6 D...

Отзывы: