Gas Connection
Restraining device
A restraining device should be fitted
when the cooker is connected to a
flexible gas supply. Any restraining
device should be secured to the fab-
ric of the building and should be able
to be released so that the cooker can
be pulled out for cleaning and mainte-
nance.
Flexible Gas Hose
A gas shut off valve must be fitted be-
tween the gas supply and the con-
nection hose. The flexible hose (not
supplied with the cooker) must be in
accordance with the relevant stand-
ards. If in doubt contact, your sup-
plier.
The rear cover boxes limit the posi-
tion of the supply point. The house
gas supply needs to terminate with a
down facing connection.
The appliance connection is located
just below hotplate level at the rear of
the cooker. (‘B’ in the figure)
The hose should be fitted so that both
inlet and outlet connections are verti-
cal so that the hose hangs down-
wards in a ‘U’ shape.
Because the height of the cooker can
be adjusted and each connection is
different it is difficult to give precise
dimensions. Ideally the house supply
connection should be in the shaded
area shown in the figure showing the
back of the cooker. (‘A’ in the figure)
After completing the gas connection,
check the cooker is gas sound with a
pressure test. When checking for gas
leaks do not use washing up liquid -
this can corrode. Use a product spe-
cifically manufactured for leak detec-
tion.
Pressure testing
The gas pressure can be measured
at the injector of one of the centre hot-
plate burners. Remove the pan sup-
port, burner head and cap. The injec-
tor is now accessible.
See Technical data section at the
back of this book for test pressures.
Reassemble burner top, making sure
it is reassembled in the correct way
on the burner body.
Electrical Connection
This appliance must be installed by a
qualified electrician to comply with the
relevant regulations and also the local
electricity supply company require-
ments.
WARNING: THIS APPLIANCE
MUST BE EARTHED
Note
The cooker must be connected to the
correct electrical supply as stated on
the voltage label on the cooker,
through a suitable cooker control unit
incorporating a double pole switch
having a contact separation of at
least 3mm in all poles. This cooker
must not be connected to an ordinary
domestic power point.
The total electrical load of the appli-
ance is approximately 7.2kW. The ca-
ble size used should be suitable for
this load and comply with all local re-
quirements.
Access to the mains terminal is
gained by removing the electrical ter-
minal cover box on the back panel.
Connect the mains cable to the cor-
rect terminals for your electrical sup-
ply type.
Check that the links are correctly fit-
ted and that the terminal screws are
tight. Secure the mains cable using
the cable clamp.
Current Operated Earth Leakage
Breakers
Where the installation is protected by
a 30-milliamp sensitivity residual cur-
rent device (RCD), the combined use
of your cooker and other domestic
appliances may occasionally cause
nuisance tripping. In these instances
the cooker circuit may need to be pro-
tected by fitting a100mA device. This
work should be carried out by a quali-
fied electrician.
Hotplate
Check each burner in turn. There is a
flame safety device that stops the
flow of gas to the burner if the flame
goes out. For each burner, turn the
control knob to the large flame sym-
bol. Press in the control knob. This
lets gas through to the burner. Keep
holding the knob pressed in and
press the igniter button or light with a
match. Keep holding the control knob
pressed in for about 10 seconds.
If when you let go of the control knob
the burner goes out, the safety device
has not held in. Wait one minute then
try again this time holding the control
pressed in for slightly longer.