Страница 1: ...ural gas to LP orifices be sure to keep the original factory installed natural gas orifices for future range conversion back to natural gas Converting the appliance for use with LP Propane Gas Tools Required 1 2 Open End Wrench 5 8 Open End Wrench 1 4 Nutdriver 10mm Nutdriver 10mm Open End Wrench or 1 Convert Pressure Regulator Before proceeding with the conversion shut off the gas supply before d...
Страница 2: ...ont burner orifice Using a rubber hose with inside diameter of approximately 1 4 hold tubing down tight over orifice Turn burner valve on For an accurate pressure check have at least two 2 other surface burners burning Be sure the gas supply inlet pressure is at least one inch above specified range manifold pressure The gas supply pressure should never be over 14 water column When properly adjuste...
Страница 3: ...oven d Settheoventobakeat350 Fandobservetheflame Ifthe flame is yellow in color increase air shutter opening size Ifthe flame is a distinct blue color but lifting away from the burner reduce the air shutter opening size e Turn offoven and allow to cool before adjusting air shutter To adjust loosen Air Shutter Lock Screw See Fig 7 reposition air shutter to FULL OPEN and tighten Air Shutter Lock Scr...