11. Technical Data
This cooker is designed for use on Natural gas, although a conversion for LP (LPG X Propane (2.54 kPa)) gas is packed with the
cooker.
INSTALLER
: Please leave these instructions with the User.
DATA BADGE LOCATION
: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION:
Australia
Connection & Test Pressures
Gas
(Rp ½ at rear right-hand side)
Electric
Natural gas
1 kPa
230 V 50 Hz
Propane
2.54 kPa
See appliance data badge for test pressures.
Dimensions
Overall height
minimum 900 mm
maximum 925 mm
Overall width
1100 mm
Overall depth
600 mm (to fascia); 650 mm (over handles)
Minimum space above hotplate
650 mm
Refer to ‘
Positioning the Cooker
’.
Ratings
Hotplate
Bypass
Screw*
Natural gas 1.0 kPa
LP gas 2.54 kPa
Input
Injector
Input
Injector
Wok burner
55
15.2 MJh
-1
internal 88
15.0 MJh
-1
internal 57
external 168
external 98
Large burner
41
12.3 MJh
-1
165
12.0 MJh
-1
89
Medium burners
33
6.2
MJh
-1
115
6.2 MJh
-1
67
Small burner
25
3.7 MJh
-1
92
3.3 MJh
-1
48
Gas burner inputs based on Gross Calorific Value.
* The valves in this range are fitted with adjustable bypass screws. The range is supplied with the bypass screws set for Natural
gas. For LPG conversion the bypass screws must be screwed all the way down.
Oven Efficiency
Ovens
Left-hand Oven
Right-hand Oven
Multi-function
Forced Air
Convection
Maximum power output @ 230 V 50 Hz
2.5 kW
2.5 kW
Energy efficiency class on a scale of A (more efficient) to G (less efficient)
A
A
Energy consumption based on standard load
0.95 kWh
0.90 kWh
Usable volume (litres)
69
69
Size
Large
Large
Time to cook standard load
41 minutes
38 minutes
Surface area of the grid
1400 cm
2
1400 cm
2
Grill
2.3 kW
Maximum total electrical load at 230 V
(approximate total including oven lights, oven fan, etc.)
:
7.4 kW.