background image

01

Pan 

detection

error

Use of unsuitable pan material

Re-set required

Defective coil

Use suitable pan. 

Switch unit off for 10 seconds, then on.

Engineer required.

User

Engineer

02

No coil 

current

Re-set required

Coil failure

Switch unit off for 10 seconds, then on.

Engineer required.

User

Engineer

03

Excessive

generator

temperature

Re-set required

Air flow / filter blocked

Excessive ambient temperature

Generator error

Switch unit off for 10 seconds, then on.

Clean filter/remove obstruction.

Ventilate working area.

Switch off. Allow to cool. Replace generator.

User

Engineer

04

Excessive

cooking 

zone 

temperature 

Re-set required

Pan empty or too hot

Pan base uneven / distorted

Faulty temperature sensor

(constantly recording ambient)

Switch unit off for 10 seconds, then on.

Check pan has not boiled dry or is empty.

Check/replace pan. 

Engineer required.

User

Engineer

05

Control 

failure

Faulty control or incorrect wiring

Switch unit off for 10 seconds.

Check control connections to generator.

Replace control assembly.

User

Engineer

06

Internal

temperature

of generator

excessive

Re-set required

Switch unit off for 10 seconds, then on.

Refer to Fault 03.

User

Engineer

07

Cooking

zone 

temperature

sensor

Reset required

Switch unit off for 10 seconds, then on

Check sensor connections. Replace coil

assembly. Refer to Fault 04.

User

Engineer

08

Mains supply

failure

Re-set required

Fault with mains supply

Switch unit off for 10 seconds, then on.

Check mains supply.

User

Engineer

09

N/A

N/A

N/A

Code

Error

Cause

Action

U / E

6

Содержание E3901i

Страница 1: ...ICE CALL On completion of the installation these instructions should be left with the Engineer in Charge for reference during servicing In addition the Users Instructions should be handed to the User...

Страница 2: ...ight bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been repor...

Страница 3: ...on a cooking zone Pan bases should be constructed of a ferrous material and cannot be less than 120mm 12cm in diameter d Ensure that corresponding LED stops flashing and remains lit e Lift pan from zo...

Страница 4: ...ts to spade terminal beside LED body flat side Remove two wires connected to LED Remove control knob Undo fixings that secure control to panel Remove associated LED if required Remove main access pane...

Страница 5: ...the solution to rectify the condition SUPPLY PROTECTION DEVICE The appliance is fitted with a miniature circuit breaker MCB as additional protection against over current If unit fails to operate or sh...

Страница 6: ...uneven distorted Faulty temperature sensor constantly recording ambient Switch unit off for 10 seconds then on Check pan has not boiled dry or is empty Check replace pan Engineer required User Enginee...

Страница 7: ...that current does not reflect what controls require Switch unit off for 10 seconds then on Engineer required User Engineer 13 Mains connection error Re set required Mains voltage is too high or too lo...

Страница 8: ...TWISTED THROUGH FERRITE BEAD FERRITE BEAD 16 ON 4 3 2 1 OFF ON 4 3 2 1 OFF L1 N E USE TWO TERMINALS FOR 0 5mm CABLE LABELED 9F 4 8 7 6 CHANNEL C 2 CHANNEL B 1 9 10 11 12 13 14 15 16 15 14 13 9 10 11 1...

Страница 9: ...E E F1 S1 S2 Terminal Block MCB Generator Front Control Rear Control Rear LED Front LED Front Coil Rear Coil Cables Twisted Together Cables Twisted Together Around Ferrite B B C C 1 2 3 4 4 4 6 6 7 7...

Страница 10: ...10...

Отзывы: