Replace and re-assemble in reverse order.

Refer to wiring diagram A in Section 5 of this manual.

3.7 TO REPLACE SWITCH CABLES

Access cables as detailed in Section 3.6.

Switches are connected to generator LIN connection via

a bus sstem, refer to wiring diagram on Page 8.

Disconnect relevant cable from switch and replace.

Re-assemble in reverse order.

SECTION 4 - SPARES

When ordering spare parts, always quote appliance type

and serial number. 

This information will be found on data badge attached to

base plate. 

3.5kW Generator Assembly

5kW Generator Assembly

3.5kW Induction Coil

5kW Induction Coil

Control Knob

Control Switch & LED

(Green)

MCB

Ferrite Bead

SECTION 5 - TROUBLESHOOTING

If a fault occurs during use, an error code will be

displayed in a series of  flashes.

These correspond to the numbers in the code column of

the following table.

For example, 6 short flashes followed by an extended

flash would indicate error code 06

(Generator internal

temperature too high).

The codes are provided to diagnose possible faults and

the action required to remedy any such condition.

Note: Most faults can be rectified by simply

switching the unit off for 10 seconds. After this time,

turn power back on at mains supply.

If the fault continues to occur after this action then

please refer to the table. This will provide the

solution to rectify the condition. 

SUPPLY PROTECTION DEVICE

The appliance is fitted with a miniature circuit breaker

(MCB)

as additional protection against over current.

If unit fails to operate or show any operational indicators,

carry out the following check:

● Isolate power at main switch.

● Remove rear access panel.

● Find MCB located on rear mains panel.

● Ensure MCB has not tripped during use or 

whilst in transit during delivery.

● MCB should be at ‘ON’ Position.

● Switch appliance mains power ON at isolator.

● Ensure appliance powers up and does not 

trip MCB again. 

● Rear access panel MUST BE REPLACED.

5.1 TESTING THE COIL OR COIL SENSOR

Disconnect from mains supply.

Remove rear access panel.  Refer to Section 3.3.

Tilt terminal panel to access connection wires.

Identify appropriate wires, disconnect and test as follows:

Use a multimeter on a resistance 

(Ω)

setting.

A correct inductor coil reading will indicate 0Ω.

A correct temperature sensor reading will indicate

approximately 985Ω

5.2 LOAD TEST

Check current in each phase by setting both cooking

zones to Position 10. 

Position a water-filled pan upon both zones.

Use a clamp meter to measure the following data. 

5.2.1 10kW model

Terminal

Actual

Max

I

 Min

L1

15.3A

16.8A

14.5A

L2

15.3A

16.8A

14.5A

L3

15.3A

16.8A

14.5A

Total

45.9A

50.4A

43.5A

5.2.2 7kW model

Terminal

Actual

Max

I

 Min

L1

10.7A

12A

10.3A

L2

10.7A

12A

10.3A

L3

10.7A

12A

10.3A

Total

32.1A

36A

30.9A

Note

: If any current is outwith these tolerances,

the cause must be investigated and rectified.

Содержание E3901i

Страница 1: ...ICE CALL On completion of the installation these instructions should be left with the Engineer in Charge for reference during servicing In addition the Users Instructions should be handed to the User...

Страница 2: ...ight bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been repor...

Страница 3: ...on a cooking zone Pan bases should be constructed of a ferrous material and cannot be less than 120mm 12cm in diameter d Ensure that corresponding LED stops flashing and remains lit e Lift pan from zo...

Страница 4: ...ts to spade terminal beside LED body flat side Remove two wires connected to LED Remove control knob Undo fixings that secure control to panel Remove associated LED if required Remove main access pane...

Страница 5: ...the solution to rectify the condition SUPPLY PROTECTION DEVICE The appliance is fitted with a miniature circuit breaker MCB as additional protection against over current If unit fails to operate or sh...

Страница 6: ...uneven distorted Faulty temperature sensor constantly recording ambient Switch unit off for 10 seconds then on Check pan has not boiled dry or is empty Check replace pan Engineer required User Enginee...

Страница 7: ...that current does not reflect what controls require Switch unit off for 10 seconds then on Engineer required User Engineer 13 Mains connection error Re set required Mains voltage is too high or too lo...

Страница 8: ...TWISTED THROUGH FERRITE BEAD FERRITE BEAD 16 ON 4 3 2 1 OFF ON 4 3 2 1 OFF L1 N E USE TWO TERMINALS FOR 0 5mm CABLE LABELED 9F 4 8 7 6 CHANNEL C 2 CHANNEL B 1 9 10 11 12 13 14 15 16 15 14 13 9 10 11 1...

Страница 9: ...E E F1 S1 S2 Terminal Block MCB Generator Front Control Rear Control Rear LED Front LED Front Coil Rear Coil Cables Twisted Together Cables Twisted Together Around Ferrite B B C C 1 2 3 4 4 4 6 6 7 7...

Страница 10: ...10...

Отзывы: