5
Replace and re-assemble in reverse order.
Refer to wiring diagram A in Section 5 of this manual.
3.7 TO REPLACE SWITCH CABLES
Access cables as detailed in Section 3.6.
Switches are connected to generator LIN connection via
a bus sstem, refer to wiring diagram on Page 8.
Disconnect relevant cable from switch and replace.
Re-assemble in reverse order.
SECTION 4 - SPARES
When ordering spare parts, always quote appliance type
and serial number.
This information will be found on data badge attached to
base plate.
3.5kW Generator Assembly
5kW Generator Assembly
3.5kW Induction Coil
5kW Induction Coil
Control Knob
Control Switch & LED
(Green)
MCB
Ferrite Bead
SECTION 5 - TROUBLESHOOTING
If a fault occurs during use, an error code will be
displayed in a series of flashes.
These correspond to the numbers in the code column of
the following table.
For example, 6 short flashes followed by an extended
flash would indicate error code 06
(Generator internal
temperature too high).
The codes are provided to diagnose possible faults and
the action required to remedy any such condition.
Note: Most faults can be rectified by simply
switching the unit off for 10 seconds. After this time,
turn power back on at mains supply.
If the fault continues to occur after this action then
please refer to the table. This will provide the
solution to rectify the condition.
SUPPLY PROTECTION DEVICE
The appliance is fitted with a miniature circuit breaker
(MCB)
as additional protection against over current.
If unit fails to operate or show any operational indicators,
carry out the following check:
● Isolate power at main switch.
● Remove rear access panel.
● Find MCB located on rear mains panel.
● Ensure MCB has not tripped during use or
whilst in transit during delivery.
● MCB should be at ‘ON’ Position.
● Switch appliance mains power ON at isolator.
● Ensure appliance powers up and does not
trip MCB again.
● Rear access panel MUST BE REPLACED.
5.1 TESTING THE COIL OR COIL SENSOR
Disconnect from mains supply.
Remove rear access panel. Refer to Section 3.3.
Tilt terminal panel to access connection wires.
Identify appropriate wires, disconnect and test as follows:
Use a multimeter on a resistance
(Ω)
setting.
A correct inductor coil reading will indicate 0Ω.
A correct temperature sensor reading will indicate
approximately 985Ω
5.2 LOAD TEST
Check current in each phase by setting both cooking
zones to Position 10.
Position a water-filled pan upon both zones.
Use a clamp meter to measure the following data.
5.2.1 10kW model
Terminal
I
Actual
I
Max
I
Min
L1
15.3A
16.8A
14.5A
L2
15.3A
16.8A
14.5A
L3
15.3A
16.8A
14.5A
Total
45.9A
50.4A
43.5A
5.2.2 7kW model
Terminal
I
Actual
I
Max
I
Min
L1
10.7A
12A
10.3A
L2
10.7A
12A
10.3A
L3
10.7A
12A
10.3A
Total
32.1A
36A
30.9A
Note
: If any current is outwith these tolerances,
the cause must be investigated and rectified.