1.4 SUPPLY CONNECTION
Mains input connecting cable will conform to code
designation 60245 IEC 57, H07RN-F cable, 4mm
2
(4 core) is suitable.
Cable entry is at unit rear and is suitable for 25mm
conduit. A suitably rated isolating switch with contact
separation of at least 3mm in all poles must be installed
and wiring executed in accordance with relevent
regulations.
Access to terminal block is gained by removing the
access panel close to cable entry gland on rear panel.
1.5 ELECTRICAL RATINGS
Electrical loading is as stated on appliance data plate.
After installation, the engineer should check satisfactory
operation and demonstrate method of use to kitchen staff.
Location of mains isolating switch should be identified for
use in the event of an emergency or during cleaning.
SECTION 2 - ASSEMBLY and
COMMISSIONING
NOTE: Users MUST be made aware that individuals
fitted with a pacemaker should consult their doctor if
in close proximity to this unit. This induction unit
emanates an 18 - 22Khz output that may effect older
types of pacemaker
.
2.1 ASSEMBLY
a) Unpack and level appliance.
b) Ensure fan intake filter is fitted and secured in position
below control panel.
2.2 CONNECTION TO AN ELECTRICAL SUPPLY
Connect as detailed in Sections 1.3 and 1.4.
2.3 STARTING UP
a) Switch both cooking zones on to position 10.
b) Ensure both LEDs light and begin to flash.
c) Place a suitable pan
(filled with water)
upon a cooking
zone.
(Pan bases should be constructed of a ferrous
material and cannot be less than 120mm (12cm) in
diameter.)
d) Ensure that corresponding LED stops flashing and
remains lit.
e) Lift pan from zone: LED should again begin to flash.
f) This indicates that
“Pan Detection”
feature is working.
g) Repeat on the other zone.
h) Switch control off.
SECTION 1 - INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE
BEEN PROTECTED BY THE MANUFACTURER ARE
NOT TO BE ADJUSTED BY THE INSTALLER.
1.1 MODEL NUMBER, NETT WEIGHT
and DIMENSIONS
1.2 SITING
The appliance should be installed in a well-lit position on
a firm, level, non-combustable floor. The unit is provided
with rear stand-off plates to ensure a 50mm gap between
appliance and rear wall.
These must NEVER be bent, twisted or deformed,
the 50mm gap must never be covered, blocked or
reduced.
Nothing shall be placed UNDER the appliance.
Where unit is to be positioned in close proximity to a wall,
partition, kitchen furniture, decorative finishes, etc.,
it is recommended that these be constructed of a
non-combustible material.
Close attention should be paid to Fire Regulations.
1.3 ELECTRICAL SUPPLY
The unit is suitable for AC supplies only.
The standard terminal arrangement is:
3 phase/no neutral 4 wire connection
(400V 3~)
WARNING – THIS APPLIANCE MUST BE EARTHED
Phase 1
BROWN
Phase 2
BLACK
Phase 3
GREY
Earth
YELLOW / GREEN
Model
Width
(mm)
Depth
(mm)
Height
(mm)
Weight
(kg)
E3901i Induction
Table on legs
400
820
890
42
E3901i Induction
Table on castors
400
820
890
57
E3902i Induction
Table on legs
400
820
890
42
E3902i Induction
Table on castors
400
820
890
57
3