6.6 COMMISSIONING
Refer to section 2.0 for operation. If safety thermostat is activated, refer to section 2.5 to
reset it.
Carry out the following operation:
6.6.1 Turn the main gas supply on to the appliance.
6.6.2 Remove front facia as stated in section 8.1. Connect a suitable pressure gauge to the
test points on the gas valve shown below and ensure the gas pressures are correct
(see section 4.3 for gas pressures).
6.6.3
Natural Gas Appliance only
– Adjust Governor as shown in section 8.9.
6.6.4 Fill pan with cold oil to the MIN mark.
6.6.5 Light all pilots to ensure they all stay lit.
6.6.6 Turn on main burners and check for flame stability.
6.6.7 Set the gas control to HIGH and turn the temperature control to 190°C. Let the
appliance heat up. When the burner switches off, check the temperature. Ensure the
temperature is 190°C +/- 5°C.
6.6.8 Switch appliance off
If the appliance does not operate correctly please refer to section 10.0 and rectify the
problem.